ENTRY D0303 20160518 D030300000001 SUBENT D0303001 20160518 20161117 D030300100001 BIB 11 25 D030300100002 TITLE Simultaneous production of 57Co and 109Cd in cyclotron D030300100003 AUTHOR (L.Landini, J.A.Osso Jr) D030300100004 INSTITUTE (3BZLUSP) D030300100005 REFERENCE (J,JRN,250,429,2001) D030300100006 FACILITY (CYCLO,3BZLUSP) CV-28 cyclotron of IPEN-CNEN/SP D030300100007 METHOD (EXTB,GSPEC) D030300100008 (ACTIV) The irradiation times varied from 10 min to 1 hD030300100009 and the average beam currents were between D030300100010 0.77 and 1.5 uA. D030300100011 MONITOR (29-CU-63(P,2N)30-ZN-62,,SIG) D030300100012 (29-CU-65(P,N)30-ZN-65,,SIG) D030300100013 A natCu (63Cu - 69.17% and 65Cu - 30.83%)8 foil with D030300100014 a thickness of 50 mu-m was used in one irradiation, in D030300100015 order to monitor the beam current and energy. D030300100016 DECAY-MON (30-ZN-62,9.3HR,DG,596.63,0.2570) D030300100017 (30-ZN-65,5856.HR,DG,1115.55,0.5075) D030300100018 DETECTOR (HPGE) HPGe detector, with resolution of 1.8 keV (FWHM)D030300100019 at the 1332 keV peak related to 60Co. D030300100020 STATUS (TABLE) Data from Table 2. D030300100021 HISTORY (20060614C) SD D030300100022 (20090204U) On. AUTHOR corrected, FACILITY updated D030300100023 (20160518A) VS. 002-012(even) 014-016 SF8: DT->PHY/MSC D030300100024 SF5=IND deleted IN 002,010,012. D030300100025 DECAY-DATA corrected in 010,012,014. D030300100026 003-013 (odd) deleted-activity after cooling. D030300100027 ENDBIB 25 0 D030300100028 COMMON 1 3 D030300100029 EN D030300100030 MEV D030300100031 24.0 D030300100032 ENDCOMMON 3 0 D030300100033 ENDSUBENT 32 0 D030300199999 SUBENT D0303002 20160518 20161117 D030300200001 BIB 5 12 D030300200002 REACTION (28-NI-0(P,X)27-CO-55,,TTY,,PHY/MSC) D030300200003 EOB activity for 1 uA-h dose without specification of D030300200004 irradiation current and time. D030300200005 DECAY-DATA (27-CO-55,17.54HR,DG,931.10,0.75) D030300200006 SAMPLE natNi were used in all the irradiations, with the D030300200007 isotopic composition as follows: 58Ni (natural D030300200008 abundance - 68.27%); 60Ni (26.10%); 61Ni (1.13%); D030300200009 62Ni (3.59%) and 64Ni (0.91%). The area of each foil D030300200010 was 13x13 mm2. The thickness of Ni varied between D030300200011 607 and 662 u-m. D030300200012 ERR-ANALYS (DATA-ERR) No information on sources of uncertainties. D030300200013 HISTORY (20160518A) VS. SF8: DT->PHY/MSC, SF5=IND deleted. D030300200014 ENDBIB 12 0 D030300200015 NOCOMMON 0 0 D030300200016 DATA 2 1 D030300200017 DATA DATA-ERR D030300200018 KBQ/MUAHR KBQ/MUAHR D030300200019 33410. 4700. D030300200020 ENDDATA 3 0 D030300200021 ENDSUBENT 20 0 D030300299999 NOSUBENT D0303003 20160622 20161117 D030300300001 SUBENT D0303004 20160518 20161117 D030300400001 BIB 5 12 D030300400002 REACTION (28-NI-0(P,X)27-CO-56,IND,TTY,,PHY/MSC) D030300400003 EOB activity for 1 uA-h dose without specification of D030300400004 irradiation current and time. D030300400005 DECAY-DATA (27-CO-56,78.76D,DG,846.77,0.999) D030300400006 SAMPLE natNi were used in all the irradiations, with the D030300400007 isotopic composition as follows: 58Ni (natural D030300400008 abundance - 68.27%); 60Ni (26.10%); 61Ni (1.13%); D030300400009 62Ni (3.59%) and 64Ni (0.91%). The area of each foil D030300400010 was 13x13 mm2. The thickness of Ni varied between D030300400011 607 and 662 u-m. D030300400012 ERR-ANALYS (DATA-ERR) No information on sources of uncertainties. D030300400013 HISTORY (20160518A) VS. SF8: DT->PHY/MSC. D030300400014 ENDBIB 12 0 D030300400015 NOCOMMON 0 0 D030300400016 DATA 2 1 D030300400017 DATA DATA-ERR D030300400018 KBQ/MUAHR KBQ/MUAHR D030300400019 16.5 3.3 D030300400020 ENDDATA 3 0 D030300400021 ENDSUBENT 20 0 D030300499999 NOSUBENT D0303005 20160622 20161117 D030300500001 SUBENT D0303006 20160518 20161117 D030300600001 BIB 5 12 D030300600002 REACTION (28-NI-0(P,X)27-CO-57,IND,TTY,,PHY/MSC) D030300600003 EOB activity for 1 uA-h dose without specification of D030300600004 irradiation current and time. D030300600005 DECAY-DATA (27-CO-57,271.3D,DG,122.56,0.848) D030300600006 SAMPLE natNi were used in all the irradiations, with the D030300600007 isotopic composition as follows: 58Ni (natural D030300600008 abundance - 68.27%); 60Ni (26.10%); 61Ni (1.13%); D030300600009 62Ni (3.59%) and 64Ni (0.91%). The area of each foil D030300600010 was 13x13 mm2. The thickness of Ni varied between D030300600011 607 and 662 mu-m. D030300600012 ERR-ANALYS (DATA-ERR) No information on sources of uncertainties. D030300600013 HISTORY (20160518A) VS. SF8: DT->PHY/MSC. D030300600014 ENDBIB 12 0 D030300600015 NOCOMMON 0 0 D030300600016 DATA 2 1 D030300600017 DATA DATA-ERR D030300600018 KBQ/MUAHR KBQ/MUAHR D030300600019 948. 240. D030300600020 ENDDATA 3 0 D030300600021 ENDSUBENT 20 0 D030300699999 NOSUBENT D0303007 20160622 20161117 D030300700001 SUBENT D0303008 20160518 20161117 D030300800001 BIB 5 12 D030300800002 REACTION (28-NI-0(P,X)27-CO-58,,TTY,,PHY/MSC) D030300800003 EOB activity for 1 uA-h dose without specification of D030300800004 irradiation current and time. D030300800005 DECAY-DATA (27-CO-58-G,70.78D,DG,810.77,0.994) D030300800006 SAMPLE natNi were used in all the irradiations, with the D030300800007 isotopic composition as follows: 58Ni (natural D030300800008 abundance - 68.27%); 60Ni (26.10%); 61Ni (1.13%); D030300800009 62Ni (3.59%) and 64Ni (0.91%). The area of each foil D030300800010 was 13x13 mm2. The thickness of Ni varied between D030300800011 607 and 662 mu-m. D030300800012 ERR-ANALYS (DATA-ERR) No information on sources of uncertainties. D030300800013 HISTORY (20160518A) VS. SF8: DT->PHY/MSC. D030300800014 ENDBIB 12 0 D030300800015 NOCOMMON 0 0 D030300800016 DATA 2 1 D030300800017 DATA DATA-ERR D030300800018 KBQ/MUAHR KBQ/MUAHR D030300800019 37. 8.5 D030300800020 ENDDATA 3 0 D030300800021 ENDSUBENT 20 0 D030300899999 NOSUBENT D0303009 20160622 20161117 D030300900001 SUBENT D0303010 20160518 20161117 D030301000001 BIB 5 13 D030301000002 REACTION (28-NI-0(P,X)28-NI-56,,TTY,,PHY/MSC) D030301000003 EOB activity for 1 uA-h dose without specification of D030301000004 irradiation current and time. D030301000005 DECAY-DATA (28-NI-56,6.1D,DG,158.38,0.988) D030301000006 SAMPLE natNi were used in all the irradiations, with the D030301000007 isotopic composition as follows: 58Ni (natural D030301000008 abundance - 68.27%); 60Ni (26.10%); 61Ni (1.13%); D030301000009 62Ni (3.59%) and 64Ni (0.91%). The area of each foil D030301000010 was 13x13 mm2. The thickness of Ni varied between D030301000011 607 and 662 mu-m. D030301000012 ERR-ANALYS (DATA-ERR) No information on sources of uncertainties. D030301000013 HISTORY (20160518A) VS. SF8: DT->PHY/MSC, SF5=IND deleted. D030301000014 DECAY-DATA corrected. D030301000015 ENDBIB 13 0 D030301000016 NOCOMMON 0 0 D030301000017 DATA 2 1 D030301000018 DATA DATA-ERR D030301000019 KBQ/MUAHR KBQ/MUAHR D030301000020 45. 12. D030301000021 ENDDATA 3 0 D030301000022 ENDSUBENT 21 0 D030301099999 NOSUBENT D0303011 20160622 20161117 D030301100001 SUBENT D0303012 20160518 20161117 D030301200001 BIB 5 13 D030301200002 REACTION (28-NI-0(P,X)28-NI-57,,TTY,,PHY/MSC) D030301200003 EOB activity for 1 uA-h dose without specification of D030301200004 irradiation current and time. D030301200005 DECAY-DATA (28-NI-57,36.HR,DG,1377.63,0.817) D030301200006 SAMPLE natNi were used in all the irradiations, with the D030301200007 isotopic composition as follows: 58Ni (natural D030301200008 abundance - 68.27%); 60Ni (26.10%); 61Ni (1.13%); D030301200009 62Ni (3.59%) and 64Ni (0.91%). The area of each foil D030301200010 was 13x13 mm2. The thickness of Ni varied between D030301200011 607 and 662 mu-m. D030301200012 ERR-ANALYS (DATA-ERR) No information on sources of uncertainties. D030301200013 HISTORY (20160518A) VS. SF8: DT->PHY/MSC, SF5=IND deleted. D030301200014 DECAY-DATA corrected. D030301200015 ENDBIB 13 0 D030301200016 NOCOMMON 0 0 D030301200017 DATA 2 1 D030301200018 DATA DATA-ERR D030301200019 KBQ/MUAHR KBQ/MUAHR D030301200020 48271. 6610. D030301200021 ENDDATA 3 0 D030301200022 ENDSUBENT 21 0 D030301299999 NOSUBENT D0303013 20160622 20161117 D030301300001 SUBENT D0303014 20160518 20161117 D030301400001 BIB 5 11 D030301400002 REACTION (47-AG-0(P,X)48-CD-107,,TTY,,PHY/MSC) D030301400003 EOB activity for 1 uA-h dose without specification of D030301400004 irradiation current and time. D030301400005 DECAY-DATA (48-CD-107,6.5HR,DG,22.1,0.89) D030301400006 SAMPLE natAg foils were used in all the irradiations, with D030301400007 the isotopic composition 107Ag (51.83%) and D030301400008 109Ag (48.17%), respectively.8 The area of each foil D030301400009 was 13x13 mm2. The thickness of Ag varied between D030301400010 228 and 328 mu-m. D030301400011 ERR-ANALYS (DATA-ERR) No information on sources of uncertainties. D030301400012 HISTORY (20160518A) VS. SF8: DT->(PHY), DECAY-DATA corrected. D030301400013 ENDBIB 11 0 D030301400014 NOCOMMON 0 0 D030301400015 DATA 2 1 D030301400016 DATA DATA-ERR D030301400017 KBQ/MUAHR KBQ/MUAHR D030301400018 150244. 52832. D030301400019 ENDDATA 3 0 D030301400020 ENDSUBENT 19 0 D030301499999 SUBENT D0303015 20160518 20161117 D030301500001 BIB 5 11 D030301500002 REACTION (47-AG-0(P,X)48-CD-109,,TTY,,PHY/MSC) D030301500003 EOB activity for 1 uA-h dose without specification of D030301500004 irradiation current and time. D030301500005 DECAY-DATA (48-CD-109,462.9D,DG,88.03,0.0361) D030301500006 SAMPLE natAg foils were used in all the irradiations, with D030301500007 the isotopic composition 107Ag (51.83%) and D030301500008 109Ag (48.17%), respectively.8 The area of each foil D030301500009 was 13x13 mm2. The thickness of Ag varied between D030301500010 228 and 328 mu-m. D030301500011 ERR-ANALYS (DATA-ERR) No information on sources of uncertainties. D030301500012 HISTORY (20160518A) VS. SF8: DT->(PHY). D030301500013 ENDBIB 11 0 D030301500014 NOCOMMON 0 0 D030301500015 DATA 2 1 D030301500016 DATA DATA-ERR D030301500017 KBQ/MUAHR KBQ/MUAHR D030301500018 71.4 5.5 D030301500019 ENDDATA 3 0 D030301500020 ENDSUBENT 19 0 D030301599999 SUBENT D0303016 20160518 20161117 D030301600001 BIB 4 10 D030301600002 REACTION (47-AG-0(P,X)47-AG-106-M,,TTY,,PHY/MSC) D030301600003 EOB activity for 1 uA-h dose without specification of D030301600004 irradiation current and time. D030301600005 DECAY-DATA (47-AG-106-M,8.46D,DG,717.3,0.291) D030301600006 SAMPLE natAg foils were used in all the irradiations, with D030301600007 the isotopic composition 107Ag (51.83%) and D030301600008 109Ag (48.17%), respectively.8 The area of each foil D030301600009 was 13x13 mm2. The thickness of Ag varied between D030301600010 228 and 328 u-m. D030301600011 HISTORY (20160518A) VS. SF8: DT->(PHY). D030301600012 ENDBIB 10 0 D030301600013 NOCOMMON 0 0 D030301600014 DATA 1 1 D030301600015 DATA D030301600016 KBQ/MUAHR D030301600017 0.37 D030301600018 ENDDATA 3 0 D030301600019 ENDSUBENT 18 0 D030301699999 ENDENTRY 16 0 D030399999999