DARPE: Search Results
Entry No. D1629

Y.Hatsukawa1,T.Ohtsuki1,K.Sueki1,H.Nakahara1,I.Kohno2, M.Magara3,N.Shinohara3
Tokyo Metropolitan Univ., Hachioji, Tokyo1
Inst.of Physical and Chemical Res. (RIKEN2
Japan Atomic Research Institute (JAERI3
Nuclear Physics, Section A500(1989)90


ALPHA DECAY PROPERTIES OF LIGHT EINSTENIUM ISOTOPES

Click on the data number to see the plot. Or select the box to plot multiple data.
DataFilePhysical quantitiesReaction(s)Energies
1 *ENGY-EMT-LAB XSECTN-RATIO
ENGY-EMT-LAB: Energy of emitted particle in lab. system #5; XSECTN-RATIO: Cross section ratio #1
249CF(P,N)249ES; between 18 and 33) MEV
2 *ENGY-EMT-LAB XSECTN-RATIO
ENGY-EMT-LAB: Energy of emitted particle in lab. system #5; XSECTN-RATIO: Cross section ratio #1
249CF(P,2*N)248ES; between 18 and 33) MEV
3 *ENGY-EMT-LAB XSECTN-RATIO
ENGY-EMT-LAB: Energy of emitted particle in lab. system #5; XSECTN-RATIO: Cross section ratio #1
249CF(P,3*N)247ES; between 18 and 33) MEV
4 *ENGY-EMT-LAB XSECTN-RATIO
ENGY-EMT-LAB: Energy of emitted particle in lab. system #5; XSECTN-RATIO: Cross section ratio #1
249CF(P,4*N)246ES; between 18 and 33) MEV
5 *ENGY-EMT-LAB XSECTN-RATIO
ENGY-EMT-LAB: Energy of emitted particle in lab. system #5; XSECTN-RATIO: Cross section ratio #1
238U(14N,5*N)247ES; between 82 and 103) MEV
6 *ENGY-EMT-LAB XSECTN-RATIO
ENGY-EMT-LAB: Energy of emitted particle in lab. system #5; XSECTN-RATIO: Cross section ratio #1
238U(14N,6*N)246ES; between 82 and 103) MEV
7 *ENGY-EMT-LAB XSECTN-RATIO
ENGY-EMT-LAB: Energy of emitted particle in lab. system #5; XSECTN-RATIO: Cross section ratio #1
238U(14N,7*N)245ES; between 82 and 103) MEV
8 *ENGY-EMT-LAB XSECTN-RATIO
ENGY-EMT-LAB: Energy of emitted particle in lab. system #5; XSECTN-RATIO: Cross section ratio #1
237NP(12C,4*N)245ES; between 82 and 103) MEV
9 *HALF-LIFE X ENGY-EMT-LAB DATA81)
ENGY-EMT-LAB: Energy of emitted particle in lab. system #5; HALF-LIFE: Half life time
249CF(P,N)249ES; 23 MEV
10 *HALF-LIFE X ENGY-EMT-LAB DATA82)
ENGY-EMT-LAB: Energy of emitted particle in lab. system #5; HALF-LIFE: Half life time
249CF(P,2*N)248ES; 23 MEV
11 *HALF-LIFE X ENGY-EMT-LAB DATA83)
ENGY-EMT-LAB: Energy of emitted particle in lab. system #5; HALF-LIFE: Half life time
249CF(P,3*N)247ES; 23 MEV
12 *HALF-LIFE X ENGY-EMT-LAB DATA84)
ENGY-EMT-LAB: Energy of emitted particle in lab. system #5; HALF-LIFE: Half life time
238U(14N,6*N)246ES; 82 MEV
13 *HALF-LIFE X ENGY-EMT-LAB DATA85)
ENGY-EMT-LAB: Energy of emitted particle in lab. system #5; HALF-LIFE: Half life time
237NP(12C,4*N)245ES; 71 MEV
14 *HALF-LIFE X ENGY-EMT-LAB DATA86)
ENGY-EMT-LAB: Energy of emitted particle in lab. system #5; HALF-LIFE: Half life time
233U(14N,4*N)243ES; 78 MEV

81) Intensity of alpha decay
82) Intensity of alpha decay
83) Intensity of alpha decay
84) Intensity of alpha decay
85) Intensity of alpha decay
86) Intensity of alpha decay
Plot the data selected in THIS page: