DARPE: Search Results
Entry No. D1893

T.Aoki1, M.Hagiwara1, M.Baba1, M.Sugimoto2, T.Miura1, N.Kawata1, A.Yamadera1
Tohoku Univ., Sendai1
Japan Atomic Research Institute (JAERI2
J. of Nuclear Science and Technology, Tokyo41(2004)399


Measurements of differential thick target neutron yields and 7Be production in the Li, 9Be(d,n) reactions for 25 MeV deuterons

Click on the data number to see the plot. Or select the box to plot multiple data.
DataFilePhysical quantitiesReaction(s)Energies
1 *ENGY-EMT-LAB DN/DOMEGA/DE
ENGY-EMT-LAB: Energy of emitted particle in lab. system #5
7LI(D,N)X; 25 MEV
2 *ENGY-EMT-LAB DN/DOMEGA/DE
ENGY-EMT-LAB: Energy of emitted particle in lab. system #5
7LI(D,N)X; 25 MEV
3 *ENGY-EMT-LAB DN/DOMEGA/DE
ENGY-EMT-LAB: Energy of emitted particle in lab. system #5
7LI(D,N)X; 25 MEV
4 *ENGY-EMT-LAB DN/DOMEGA/DE
ENGY-EMT-LAB: Energy of emitted particle in lab. system #5
7LI(D,N)X; 25 MEV
5 *ENGY-EMT-LAB DN/DOMEGA/DE
ENGY-EMT-LAB: Energy of emitted particle in lab. system #5
7LI(D,N)X; 25 MEV
6 *ENGY-EMT-LAB DN/DOMEGA/DE
ENGY-EMT-LAB: Energy of emitted particle in lab. system #5
7LI(D,N)X; 25 MEV
7 *ENGY-EMT-LAB DN/DOMEGA/DE
ENGY-EMT-LAB: Energy of emitted particle in lab. system #5
7LI(D,N)X; 25 MEV
8 *ENGY-EMT-LAB DN/DOMEGA/DE
ENGY-EMT-LAB: Energy of emitted particle in lab. system #5
7LI(D,N)X; 25 MEV
9 *ENGY-EMT-LAB DN/DOMEGA/DE
ENGY-EMT-LAB: Energy of emitted particle in lab. system #5
7LI(D,N)X; 25 MEV
10 *ENGY-EMT-LAB DN/DOMEGA/DE
ENGY-EMT-LAB: Energy of emitted particle in lab. system #5
7LI(D,N)X; 25 MEV
11 *ENGY-EMT-LAB DN/DOMEGA/DE
ENGY-EMT-LAB: Energy of emitted particle in lab. system #5
9BE(D,N)X; 25 MEV
12 *ENGY-EMT-LAB DN/DOMEGA/DE
ENGY-EMT-LAB: Energy of emitted particle in lab. system #5
9BE(D,N)X; 25 MEV
13 *ENGY-EMT-LAB DN/DOMEGA/DE
ENGY-EMT-LAB: Energy of emitted particle in lab. system #5
9BE(D,N)X; 25 MEV
14 *ENGY-EMT-LAB DN/DOMEGA/DE
ENGY-EMT-LAB: Energy of emitted particle in lab. system #5
9BE(D,N)X; 25 MEV
15 *ENGY-EMT-LAB DN/DOMEGA/DE
ENGY-EMT-LAB: Energy of emitted particle in lab. system #5
9BE(D,N)X; 25 MEV
16 *ENGY-EMT-LAB DN/DOMEGA/DE
ENGY-EMT-LAB: Energy of emitted particle in lab. system #5
9BE(D,N)X; 25 MEV
17 *ENGY-EMT-LAB DN/DOMEGA/DE
ENGY-EMT-LAB: Energy of emitted particle in lab. system #5
9BE(D,N)X; 25 MEV
18 *ENGY-EMT-LAB DN/DOMEGA/DE
ENGY-EMT-LAB: Energy of emitted particle in lab. system #5
9BE(D,N)X; 25 MEV
19 *ENGY-EMT-LAB DN/DOMEGA/DE
ENGY-EMT-LAB: Energy of emitted particle in lab. system #5
9BE(D,N)X; 25 MEV
20 *ENGY-EMT-LAB DN/DOMEGA/DE
ENGY-EMT-LAB: Energy of emitted particle in lab. system #5
9BE(D,N)X; 25 MEV
21 * TTY55)
7LI(D,X)7BE; 25 MEV
22 * TTY58)
9BE(D,X)7BE; 25 MEV

55) Corrected for decays during irradiation (Comment from M. Hagiwara, 20050810)
58) Corrected for decays during irradiation (Comment from M. Hagiwara, 20050810)
Plot the data selected in THIS page:


Last update of this script: April 12, 2006. Contact address: darpe-admin@jcprg.org