DARPE: Search Results
Entry No. D2021

H.Haba1, M.Igarashi2, K.Washiyama1, H.Matsumura1, M.Yamashita1, K.Sakamoto1,2, Y.Oura3, S.Shibata4, M.Furukawa5, I.Fujiwara6
error1
error2
Tokyo Metropolitan Univ., Hachioji, Tokyo3
Kyoto Univ.4
Japan5
Japan6
Journal of Nuclear and Radiochemical Sciences1(2000)53


Photofission of 197Au at intermediate energies

Click on the data number to see the plot. Or select the box to plot multiple data.
DataFilePhysical quantitiesReaction(s)Energies
1 *INC-ENGY-LAB-MAX SIGMA,13) SIGMA,14)
197AU(GAMMA,FISSN)131BA; between 1100 and 450 MEV
2 *INC-ENGY-LAB-MAX SIGMA,17) SIGMA,18)
197AU(GAMMA,FISSN)129BA; between 1100 and 450 MEV
3 *INC-ENGY-LAB-MAX SIGMA21)
SIGMA: Total cross section #1
197AU(GAMMA,FISSN)129BA; between 1100 and 450 MEV
4 *INC-ENGY-LAB-MAX SIGMA,24) SIGMA,25)
197AU(GAMMA,FISSN)128BA; between 1100 and 450 MEV
5 *INC-ENGY-LAB-MAX SIGMA28)
SIGMA: Total cross section #1
197AU(GAMMA,FISSN)126BA; between 1100 and 700 MEV
6 *INC-ENGY-LAB-MAX SIGMA31)
SIGMA: Total cross section #1
197AU(GAMMA,FISSN)113AG; between 1100 and 300 MEV
7 *INC-ENGY-LAB-MAX SIGMA34)
SIGMA: Total cross section #1
197AU(GAMMA,FISSN)112AG; between 1100 and 300 MEV
8 *INC-ENGY-LAB-MAX SIGMA,37) SIGMA,38)
197AU(GAMMA,FISSN)110AG; between 1100 and 300 MEV
9 *INC-ENGY-LAB-MAX SIGMA41)
SIGMA: Total cross section #1
197AU(GAMMA,FISSN)106AG; between 1100 and 400 MEV
10 *INC-ENGY-LAB-MAX SIGMA44)
SIGMA: Total cross section #1
197AU(GAMMA,FISSN)105AG; between 1100 and 450 MEV
11 *INC-ENGY-LAB-MAX SIGMA47)
SIGMA: Total cross section #1
197AU(GAMMA,FISSN)105RH; between 1100 and 300 MEV
12 *INC-ENGY-LAB-MAX SIGMA50)
SIGMA: Total cross section #1
197AU(GAMMA,FISSN)105RU; between 1100 and 300 MEV
13 *INC-ENGY-LAB-MAX SIGMA53)
SIGMA: Total cross section #1
197AU(GAMMA,FISSN)104AG; between 1100 and 300 MEV
14 *INC-ENGY-LAB-MAX SIGMA56)
SIGMA: Total cross section #1
197AU(GAMMA,FISSN)103AG; between 1100 and 400 MEV
15 *INC-ENGY-LAB-MAX SIGMA,59) SIGMA,60)
197AU(GAMMA,FISSN)103RU; between 1100 and 300 MEV
16 *INC-ENGY-LAB-MAX SIGMA,63) SIGMA,64)
197AU(GAMMA,FISSN)99MO; between 1100 and 300 MEV
17 *INC-ENGY-LAB-MAX SIGMA67)
SIGMA: Total cross section #1
197AU(GAMMA,FISSN)98NB; between 1100 and 500 MEV
18 *INC-ENGY-LAB-MAX SIGMA70)
SIGMA: Total cross section #1
197AU(GAMMA,FISSN)97RU; between 1100 and 700 MEV
19 *INC-ENGY-LAB-MAX SIGMA73)
SIGMA: Total cross section #1
197AU(GAMMA,FISSN)97NB; between 1100 and 400 MEV
20 *INC-ENGY-LAB-MAX SIGMA,76) SIGMA,77)
197AU(GAMMA,FISSN)97ZR; between 1100 and 300 MEV
21 *INC-ENGY-LAB-MAX SIGMA80)
SIGMA: Total cross section #1
197AU(GAMMA,FISSN)96TC; between 1100 and 400 MEV
22 *INC-ENGY-LAB-MAX SIGMA,83) SIGMA,84)
197AU(GAMMA,FISSN)96NB; between 1100 and 300 MEV
23 *INC-ENGY-LAB-MAX SIGMA,87) SIGMA,88)
197AU(GAMMA,FISSN)95NB; between 1100 and 350 MEV
24 *INC-ENGY-LAB-MAX SIGMA,91) SIGMA,92)
197AU(GAMMA,FISSN)95ZR; between 1100 and 300 MEV
25 *INC-ENGY-LAB-MAX SIGMA,95) SIGMA,96)
197AU(GAMMA,FISSN)92NB; between 1100 and 500 MEV
26 *INC-ENGY-LAB-MAX SIGMA,99) SIGMA,100)
197AU(GAMMA,FISSN)92SR; between 1100 and 300 MEV
27 *INC-ENGY-LAB-MAX SIGMA,103) SIGMA,104) FLAG105)
197AU(GAMMA,FISSN)91SR; between 1100 and 300 MEV
28 *INC-ENGY-LAB-MAX SIGMA,108) SIGMA,109)
197AU(GAMMA,FISSN)90Y; between 1100 and 300 MEV
29 *INC-ENGY-LAB-MAX SIGMA,112) SIGMA,113)
197AU(GAMMA,FISSN)89ZR; between 1100 and 300 MEV
30 *INC-ENGY-LAB-MAX SIGMA,116) SIGMA,117)
197AU(GAMMA,FISSN)88ZR; between 1100 and 350 MEV
31 *INC-ENGY-LAB-MAX SIGMA,120) SIGMA,121)
197AU(GAMMA,FISSN)88Y; between 1100 and 300 MEV
32 *INC-ENGY-LAB-MAX SIGMA124)
SIGMA: Total cross section #1
197AU(GAMMA,FISSN)87Y; between 1100 and 300 MEV
33 *INC-ENGY-LAB-MAX SIGMA,127) SIGMA,128)
197AU(GAMMA,FISSN)87Y; between 1100 and 300 MEV
34 *INC-ENGY-LAB-MAX SIGMA131)
SIGMA: Total cross section #1
197AU(GAMMA,FISSN)87SR; between 1100 and 300 MEV
35 *INC-ENGY-LAB-MAX SIGMA,134) SIGMA,135)
197AU(GAMMA,FISSN)86RB; between 1100 and 300 MEV
36 *INC-ENGY-LAB-MAX SIGMA,138) SIGMA,139)
197AU(GAMMA,FISSN)84RB; between 1100 and 300 MEV
37 *INC-ENGY-LAB-MAX SIGMA142)
SIGMA: Total cross section #1
197AU(GAMMA,FISSN)83SR; between 1100 and 650 MEV
38 *INC-ENGY-LAB-MAX SIGMA,145) SIGMA,146)
197AU(GAMMA,FISSN)83RB; between 1100 and 400 MEV
39 *INC-ENGY-LAB-MAX SIGMA149)
SIGMA: Total cross section #1
197AU(GAMMA,FISSN)82RB; between 1100 and 300 MEV
40 *INC-ENGY-LAB-MAX SIGMA152)
SIGMA: Total cross section #1
197AU(GAMMA,FISSN)82BR; between 1100 and 350 MEV
41 *INC-ENGY-LAB-MAX SIGMA155)
SIGMA: Total cross section #1
197AU(GAMMA,FISSN)81RB; between 1100 and 350 MEV
42 *INC-ENGY-LAB-MAX SIGMA158)
SIGMA: Total cross section #1
197AU(GAMMA,FISSN)77BR; between 1100 and 650 MEV
43 *INC-ENGY-LAB-MAX SIGMA161)
SIGMA: Total cross section #1
197AU(GAMMA,FISSN)76AS; between 1100 and 300 MEV
44 *INC-ENGY-LAB-MAX SIGMA,164) SIGMA,165)
197AU(GAMMA,FISSN)75SE; between 1100 and 650 MEV
45 *INC-ENGY-LAB-MAX SIGMA,168) SIGMA,169)
197AU(GAMMA,FISSN)74AS; between 1100 and 300 MEV
46 *INC-ENGY-LAB-MAX SIGMA172)
SIGMA: Total cross section #1
197AU(GAMMA,FISSN)73GA; between 1000 and 350 MEV
47 *INC-ENGY-LAB-MAX SIGMA175) XSECTN-MAX
SIGMA: Total cross section #1
197AU(GAMMA,FISSN)72AS; between 1100 and 500 MEV
48 *INC-ENGY-LAB-MAX SIGMA,178) SIGMA,179)
197AU(GAMMA,FISSN)72GA; between 1100 and 300 MEV
49 *INC-ENGY-LAB-MAX SIGMA,182) SIGMA,183)
197AU(GAMMA,FISSN)72ZN; between 1100 and 300 MEV
50 *INC-ENGY-LAB-MAX SIGMA186)
SIGMA: Total cross section #1
197AU(GAMMA,FISSN)71AS; between 1100 and 550 MEV
51 *INC-ENGY-LAB-MAX SIGMA,189) SIGMA,190)
197AU(GAMMA,FISSN)71ZN; between 1100 and 300 MEV
52 *INC-ENGY-LAB-MAX SIGMA193)
SIGMA: Total cross section #1
197AU(GAMMA,FISSN)69ZN; between 800 and 300 MEV
53 *INC-ENGY-LAB-MAX SIGMA196)
SIGMA: Total cross section #1
197AU(GAMMA,FISSN)66NI; between 1100 and 400 MEV
54 *INC-ENGY-LAB-MAX SIGMA,199) SIGMA,200)
197AU(GAMMA,FISSN)65NI; between 1100 and 300 MEV
55 *INC-ENGY-LAB-MAX SIGMA,203) SIGMA,204)
197AU(GAMMA,FISSN)59FE; between 1100 and 350 MEV
56 *INC-ENGY-LAB-MAX SIGMA207)
SIGMA: Total cross section #1
197AU(GAMMA,FISSN)56MN; between 1100 and 350 MEV
57 *INC-ENGY-LAB-MAX SIGMA210)
SIGMA: Total cross section #1
197AU(GAMMA,FISSN)43K; between 1100 and 300 MEV
58 *INC-ENGY-LAB-MAX SIGMA213)
SIGMA: Total cross section #1
197AU(GAMMA,FISSN)42K; between 1100 and 500 MEV

13) Cumulative cross section : Identified in gold target
14) Cumulative cross section : Identified in Mylar catcher
17) Cumulative cross section : Identified in gold target
18) Cumulative cross section : Identified in Mylar catcher
21) Cumulative cross section : Identified in gold target
24) Cumulative cross section : Identified in gold target
25) Cumulative cross section : Identified in Mylar catcher
28) Cumulative cross section : Identified in gold target
31) Cumulative cross section : Identified in gold target
34) Independent cross section : Identified in gold target
37) Independent cross section : Identified in gold target
38) Independent cross section : Identified in Mylar catcher
41) Independent cross section : Identified in gold target
44) Cumulative cross section : Identified in gold target
47) Cumulative cross section : Identified in Mylar catcher
50) Cumulative cross section : Identified in Mylar catcher
53) Independent cross section : Identified in gold target
56) Cumulative cross section : Identified in gold target
59) Cumulative cross section : Identified in gold target
60) Cumulative cross section : Identified in Mylar catcher
63) Cumulative cross section : Identified in gold target
64) Cumulative cross section : Identified in Mylar catcher
67) Independent cross section : Identified in gold target
70) Cumulative cross section : Identified in Mylar catcher
73) Independent cross section : Identified in gold target
76) Cumulative cross section : Identified in gold target
77) Cumulative cross section : Identified in Mylar catcher
80) Independent cross section : Identified in Mylar catcher
83) Independent cross section : Identified in gold target
84) Independent cross section : Identified in Mylar catcher
87) Independent cross section : Identified in gold target
88) Independent cross section : Identified in Mylar catcher
91) Cumulative cross section : Identified in gold target
92) Cumulative cross section : Identified in Mylar catcher
95) Independent cross section : Identified in gold target
96) Independent cross section : Identified in Mylar catcher
99) Cumulative cross section : Identified in gold target
100) Cumulative cross section : Identified in Mylar catcher
103) Cumulative cross section : Identified in gold target
104) Cumulative cross section : Identified in Mylar catcher
105)
108) Independent cross section : Identified in gold target
109) Independent cross section : Identified in Mylar catcher
112) Cumulative cross section : Identified in gold target
113) Cumulative cross section : Identified in Mylar catcher
116) Cumulative cross section : Identified in gold target
117) Cumulative cross section : Identified in Mylar catcher
120) Independent cross section : Identified in gold target
121) Independent cross section : Identified in Mylar catcher
124) Cumulative cross section : Identified in gold target
127) Cumulative cross section : Identified in gold target
128) Cumulative cross section : Identified in Mylar catcher
131) Independent cross section : Identified in gold target. comment)
134) Independent cross section : Identified in gold target
135) Independent cross section : Identified in Mylar catcher
138) Independent cross section : Identified in gold target
139) Independent cross section : Identified in Mylar catcher
142) Cumulative cross section : Identified in gold target
145) Cumulative cross section : Identified in gold target
146) Cumulative cross section : Identified in Mylar catcher
149) Independent cross section : Identified in gold target
152) Independent cross section : Identified in Mylar catcher
155) Cumulative cross section : Identified in gold target
158) Cumulative cross section : Identified in Mylar catcher
161) Independent cross section : Identified in gold target
164) Cumulative cross section : Identified in gold target
165) Cumulative cross section : Identified in Mylar catcher
168) Independent cross section : Identified in gold target
169) Independent cross section : Identified in Mylar catcher
172) Cumulative cross section : Identified in gold target
175) Independent cross section : Identified in gold target
178) Independent cross section : Identified in gold target
179) Independent cross section : Identified in Mylar catcher
182) Cumulative cross section : Identified in gold target
183) Cumulative cross section : Identified in Mylar catcher
186) Cumulative cross section : Identified in gold target
189) Cumulative cross section : Identified in gold target
190) Cumulative cross section : Identified in Mylar catcher
193) Independent cross section : Identified in gold target
196) Cumulative cross section : Identified in gold target
199) Cumulative cross section : Identified in gold target
200) Cumulative cross section : Identified in Mylar catcher
203) Cumulative cross section : Identified in gold target
204) Cumulative cross section : Identified in Mylar catcher
207) Cumulative cross section : Identified in Mylar catcher
210) Cumulative cross section : Identified in gold target
213) Independent cross section : Identified in gold target
Plot the data selected in THIS page:


Last update of this script: April 12, 2006. Contact address: darpe-admin@jcprg.org