DARPE: Search Results
 /*===================================================================*/
 /* NRDF D0815 Data No.1                                              */
 /*===================================================================*/
 /* Bibliography                                                      */
 /*===================================================================*/
 \\BIB,1;
 D#=D815;
 TITLE=/Analyzing power of the neutron continuum spectrum for the
        93Nb(p,nX) reaction at 65 MeV and a DWBA analysis/;
 PURPOSE=/To provide stringent test for various theories by simultaneous
          fitting of analyzing powers as well as cross sections for both
          neutron and proton spectra/;
 ATH=(H.SAKAI'1', K.HATANAKA'1', N.MATSUOKA'1', T.SAITO'1',
      A.SHIMIZU'1', T.MOTOBAYASHI'2', T.SHIBATA'1');
 INST-ATH=(2JPNRCN'1', 2JPNOSA'2');
      /* '2' Department of Physics */
 REF=PL/B;
 VLP=133(1983)375;
 RCTS=93NB(P,N)X;
 PHQS=(ENGY-SPEC'3', ANALPW, ANGL-DSTRN);
 /* '3' Double differential cross section */
 /*===================================================================*/
 /* Experimental Conditions                                           */
 /*===================================================================*/
 \\EXP,1;
 /* 2003-10-24 : Converted, Data converted to EXFOR E815 and EXFOR
    O0522 */
 ENR=X%;
 CHM=ELM;
 PHYS-FORM=SLD'4';
 /* '4' Metallic foil */
 THK-TGT=43.6MG/CM**2;
 BAC=SELF;
 POL-TGT=0%;
 ALGN-TGT=0%;
 ACC=CYC'5';
 /* '5'Isochronous cyclotron, RCNP AVF cyclotron */
 INST-ACC=2JPNRCN;
 INC-ENGY-LAB=65MEV;
 BEAM-INTNSTY=50NA'6';
 /* '6' maximum beam current */
 POL-PRJ=82.5+-2.5%'7';
 /* '7' The beam polarization was measured continuously with a
        12C-polarimeter placed down stream the main scattering chamber
 DET-PARTCL=N;
 COINC=NO;
 ANT-COINC=NO;
 DET-SYS=SCT'8';
 /* '8' two liquid scintillation counters (NE213) to detect
        neutrons */
 /* Experimental Method:
    - Time-of-flight (To determine outgoing neutron energy. The time
      resolution (FWHM) of the beam burst was typically 1.0-1.5 ns, and
      corresponding energy resolutions of the neutrons were about 4 and
      2 MeV for 50 and 30 MeV neutrons, respectively.)
 RCT=93NB(P,N)X;
 PHQ=ENGY-SPEC'9';
 /* '9' Double differential cross section */
 /*===================================================================*/
 /* Descriptive Parameters                                            */
 /*===================================================================*/
 \\DATA,1;
 INC-ENGY-LAB=65MEV;
 SYS-ERR=10%'10';
 /* '10' Estimated errors in the absolute magnitude of the cross
         section due to uncertainties in the neutron detection
         efficiency calculation */
 EMT=N;
 THTL=0DEG;
 DELTA-ENGY-EMT-LAB=0.27MEV'11';
 /* '11' Data-point reader uncertainty */
 DELTA-DSIGMA/DOMEGA/DE=+-3.0%'12';
 /* '12' Data-point reader uncertainty */
 /*===================================================================*/
 /* Data Table                                                        */
 /*===================================================================*/
 \DATA;
 ENGY-EMT-LAB DSIGMA/DOMEGA/DE
 (MEV) (MB/SR/MEV)
 23.38        5.4
 24.14       5.76
 24.92       5.66
 26.89       5.12
 27.43       6.07
 28.76       6.77
 29.75       6.11
 30.14       6.12
 30.91        6.4
 31.67       6.83
 32.05       6.84
 32.44       6.84
 33.39       7.47
 35.14        7.2
 36.49       7.54
 37.07       7.55
 38.04       7.73
 38.82       7.59
 39.79       7.45
 41.14       7.64
 41.75       7.04
 42.93       6.63
 43.91       6.37
 44.69       6.13
 45.88       5.65
 46.48       5.31
 47.85       5.01
 49.03       4.62
  49.8       4.83
 50.78       4.65
 51.79       4.02
 52.73       4.48
 53.48       4.88
 54.48       4.41
  55.1       3.81
 55.71       3.44
 56.89       3.24
 57.31        2.8
 57.72       2.58
 58.74       2.14
 59.63       1.41
 60.84       1.17
 61.47      0.969
 61.71      0.819
 63.07      0.377
 \END;
 /*===================================================================*/