DARPE: Search Results
 /*===================================================================*/
 /* NRDF D0816 Data No.1                                              */
 /*===================================================================*/
 /* Bibliography                                                      */
 /*===================================================================*/
 \\BIB,1;
 D#=D816;
 TITLE=/ Tensor analyzing powers of the proton continuum spectra from
         deuteron breakup at 56 MeV /;
 ATH=(N.MATSUOKA'1', K.HATANAKA'1', H.SAKAI'1', T.SAITO'1', K.HOSONO'1',
      T.ITAHASHI'1', A.SHIMIZU'1', M.KONDO'1', H.SAKAGUCHI'2',
      F.OHTANI'2');
 INST-ATH=(2JPNRCN'1', 2JPNKTO'2');
      /* '2' Department of Physics */
 REF=NP/A;
 VLP=408(1983)99;
 RCTS=(58NI(D,P)X, 90ZR(D,P)X);
 PHQS=(DBL-DIFF-XSECTN, TNSR-ANALPW);
 /*===================================================================*/
 /* Experimental Conditions                                           */
 /*===================================================================*/
 \\EXP,1;
 /* 2007-08-24 : Converted, N.Otuka. Converted to EXFOR E0816 */
 CHM=ELM;
 PHYS-FORM=SLD;
 POL-TGT=0%;
 ALGN-TGT=0%;
 ACC=CYC'3';
 /* '3' Isochronous cyclotron, AVF cyclotron */
 INST-ACC=2JPNRCN;
 INC-ENGY-LAB-RANGE=56MEV;
 BEAM-INTNSTY=5[40NA;
 POL-PRJ=70[80%;
 DET-PARTCL=P;
 COINC=NO;
 ANT-COINC=NO;
 DET-SYS=(SI'4',GE'4',SI'5',NAI'5',EDE);
 /* '4' To detect protons */
 /* '5' To detect protons (6, 8, 10, 13 deg) */
 RCT=58NI(D,P)X;
 PHQ=DBL-DIFF-XSECTN;
 ENR=99.8%;
 THK-TGT=3.79MG/CM**2;
 /* Data points lower than 20 MeV and higher than 45 MeV are mostly
    omitted because of high density of data points */
 /*===================================================================*/
 /* Descriptive Parameters                                            */
 /*===================================================================*/
 \\DATA,1;
 INC-ENGY-LAB=56MEV;
 STATIST-ERR=<2.5%'6';
 /* '6' Maximum statistical uncertainty (<2.5%) */
 THTL=6DEG;
 DELTA-DSIGMA/DOMEGA/DE=10%'7';
 /* '7' Uncertainty in absolute cross section, mainly due to
        uncertainty in target thickness */
 /*===================================================================*/
 /* Data Table                                                        */
 /*===================================================================*/
 \DATA;
 ENGY-EMT-LAB DSIGMA/DOMEGA/DE
 (MEV) (MB/SR/MEV)
 1.8537E+01 4.310E+01
 1.9527E+01 5.359E+01
 2.0525E+01 6.778E+01
 2.1516E+01 7.905E+01
 2.2509E+01 9.071E+01
 2.3410E+01 1.049E+02
 2.4398E+01 1.146E+02
 2.5402E+01 1.319E+02
 2.6485E+01 1.403E+02
 2.7475E+01 1.506E+02
 2.8356E+01 1.548E+02
 2.9435E+01 1.616E+02
 3.0497E+01 1.597E+02
 3.1551E+01 1.538E+02
 3.2605E+01 1.480E+02
 3.3456E+01 1.375E+02
 3.4498E+01 1.254E+02
 3.5535E+01 1.114E+02
 3.7614E+01 8.494E+01
 3.8552E+01 6.977E+01
 3.9498E+01 5.809E+01
 4.0637E+01 4.661E+01
 4.1495E+01 3.961E+01
 4.2641E+01 3.123E+01
 4.3697E+01 2.617E+01
 4.4654E+01 2.052E+01
 4.5327E+01 1.799E+01
 \END;
 /*===================================================================*/