DARPE: Search Results
 /*===================================================================*/
 /* NRDF D1240 Data No.1                                              */
 /*===================================================================*/
 /* Bibliography                                                      */
 /*===================================================================*/
 \\BIB,1;
 D#=D1240;
 TITLE=/ Spallation of tantalum, tungsten and gold by 12-GeV protons
 ATH=(Y.ASANO'1', H.KARIYA'1', S.MORI'1', M.OKANO'1', M.SAKANO'1');
 INST-ATH=(2JPNTSU'1');
      /* '1' Institute of Applied Physics */
 REF=JPJ;
 VLP=57(1988)2995;
 RCTS=(TA(P,X)X, W(P,X)X, 197AU(P,X)X);
 PHQS=XSECTN;
 /*===================================================================*/
 /* Experimental Conditions                                           */
 /*===================================================================*/
 \\EXP,1;
 /* 2007-01-19 : Converted, N.Otuka. Converted to EXFOR E1240 */
 PHQ=XSECTN;
 /* Additional results shown but not compiled
    - Charge distribution (Shown in Fig.1,2 and 3 in reference)
    - Mass distribution (Shown in Fig.4, 5 and 6 in reference)
 ENR=NAT;
 CHM=ELM;
 PHYS-FORM=SLD;
 THK-TGT=[40MG/CM**2;
 POL-TGT=0%;
 ALGN-TGT=0%;
 ACC=SYN;
 INST-ACC=2JPNKEK;
 INC-ENGY-LAB-RANGE=12GEV;
 POL-PRJ=0%;
 DET-PARTCL=GAMMA'2';
 /* '2' Decay data not shown */
 COINC=NO;
 ANT-COINC=NO;
 DET-SYS=GE(LI)'3';
 /* '3' To measure gamma-ray spectra */
 /* Experimental Method:
    - Activation
    - Gamma ray spectrometry (Measured for 4 months (Au) or 7 weeks
      (Ta, W))
 RCT=TA(P,X)X'6';
 /* '6' See DATA section for atomic number (Z) and mass number (A)
        of products */
 /*===================================================================*/
 /* Descriptive Parameters                                            */
 /*===================================================================*/
 \\DATA,1;
 INC-ENGY-LAB=12GEV;
 TOT-ERR=X%'4';
 /* '4' Uncertainty in detection efficiencies of gamma-rays and
        statistical errors for photopeak yields (Uncertainty in
        branching ratios and beam calibration are not included.) */
 SYS-ERR=10%'5';
 /* '5' Uncertainty in beam calibration */
 /*===================================================================*/
 /* Data Table                                                        */
 /*===================================================================*/
 \DATA;
 Z A ISOMER SIGMA',7' DELTA-SIGMA''
 (NODIM) (NODIM) (NODIM) (MB) (MB)
 19. 42 X 3.63 +-0.43
 21. 44 1 1.32 +-0.13
 21. 48 X 1.04 +-0.11
 23. 48 X 0.98 +-0.08
 25. 52 X 0.63 +-0.05
 26. 59 X 1.27 +-0.13
 28. 57 X 0.73 +-0.11
 30. 69 1 0.74 +-0.10
 33. 76 X 3.92 +-0.27
 35. 76 X 1.12 +-0.14
 39. 86 X 5.07 +-0.65
 41. 95 0 0.41 +-0.04
 41. 95 1 2.77 +-0.35
 43. 96 X 2.75 +-0.27
 47. 106 1 2.35 +-0.40
 51. 120 X 0.20 +-0.02
 52. 119 1 1.46 +-0.10
 58. 135 X 15.5 +-1.5
 67. 160 X 17.4 +-1.3
 69. 166 X 19.9 +-1.3
 \END;
 /*===================================================================*/