DARPE: Search Results
 /*===================================================================*/
 /* NRDF D1241 Data No.1                                              */
 /*===================================================================*/
 /* Bibliography                                                      */
 /*===================================================================*/
 \\BIB,1;
 D#=D1241;
 TITLE=/ Spallation and fission yields in the interactions of
         tantalum, tungsten, and gold with 500-MeV protons /;
 ATH=(Y.ASANO'1', S.MORI'1', M.NOGUCHI'1', M.SAKANO'1', K.KATOH'2',
      K.KONDO'2');
 INST-ATH=(2JPNTSU'1', 2JPNKEK'2');
      /* '1' Institute of Applied Physics */
 REF=JPJ;
 VLP=54(1985)3734;
 RCTS=(TA(P,X)X, W(P,X)X, 197AU(P,X)X);
 PHQS=XSECTN;
 /*===================================================================*/
 /* Experimental Conditions                                           */
 /*===================================================================*/
 \\EXP,1;
 /* 2007-01-19 : Converted, N.Otuka. Converted to EXFOR E1241 */
 PHQ=XSECTN;
 /* Additional results shown but not compiled
    - Mass distribution (Shown in Fig.1 and 2 in reference)
 ENR=NAT;
 CHM=ELM;
 PHYS-FORM=SLD;
 THK-TGT=[40MG/CM**2;
 POL-TGT=0%;
 ALGN-TGT=0%;
 ACC=SYN;
 INST-ACC=2JPNKEK;
 INC-ENGY-LAB-RANGE=500MEV;
 POL-PRJ=0%;
 DET-PARTCL=GAMMA'3';
 /* '3' Decay data not given */
 COINC=NO;
 ANT-COINC=NO;
 DET-SYS=GE(LI)'4';
 /* '4' Used for gamma-ray spectroscopy */
 /* Experimental Method:
    - Stacked target irradiation (Total thickness of 1 g/cm2)
    - Activation (Irradiated for 3 min)
    - Gamma ray spectrometry (Measured for 7 months and also measured
      for 12 days 16 months, starting about 12 hours after irradiation)
 RCT=TA(P,X)X'6';
 /* '6' See DATA section for atomic number (Z) and mass number (A)
        of products */
 /*===================================================================*/
 /* Descriptive Parameters                                            */
 /*===================================================================*/
 \\DATA,1;
 INC-ENGY-LAB=500MEV;
 TOT-ERR=X%'5';
 /* '5' Uncertainty in detection efficiency of gamma rays and
        statistical uncertainties for photo-yields (Possible
        uncertainty in branching ratios of gamma rays and beam
        intensity calibration are not included.) */
 /*===================================================================*/
 /* Data Table                                                        */
 /*===================================================================*/
 \DATA;
 Z A ISOMER SIGMA'7' DELTA-SIGMA
 (NODIM) (NODIM) (NODIM) (MB) (MB)
 41. 92 1 0.19 +-0.02
 43. 96 X 0.28 +-0.05
 63. 146 X 6.1 +-0.7
 65. 154 X 0.62 +-0.08
 65. 156 X 3.2 +-0.4
 69. 166 X 60 +-5
 71. 172 X 9.5 +-0.8
 71. 174 X 8 +-1
 71. 177 1 2.4 +-0.4
 72. 180 1 1.5 +-0.2
 \END;
 /*===================================================================*/