DARPE: Search Results
 /*===================================================================*/
 /* NRDF D1243 Data No.1                                              */
 /*===================================================================*/
 /* Bibliography                                                      */
 /*===================================================================*/
 \\BIB,1;
 D#=D1243;
 TITLE=/ Target dependence of charge distributions in spallation
         reactions of medium-mass nuclei with 12 GeV protons /;
 ATH=(T.ASANO'1', Y.ASANO'1', Y.IGUCHI'1', H.KUDO'1', S.MORI'1',
      M.NOGUCHI'1', Y.TAKADA'1', H.HIRABAYASHI'2', H.IKEDA'2',
      K.KATOH'2', K.KONDO'2', M.TAKASAKI'2', T.TOMINAKA'2',
      A.YAMAMOTO'2');
 INST-ATH=(2JPNTSU'1', 2JPNKEK'2');
      /* '1' Institute of Applied Physics */
 REF=PR/C;
 VLP=28(1983)1718;
 RCTS=(TI(P,X)X, FE(P,X)X, 59CO(P,X)X, NI(P,X)X, CU(P,X)X, ZN(P,X)X);
 PHQS=XSECTN;
 /*===================================================================*/
 /* Experimental Conditions                                           */
 /*===================================================================*/
 \\EXP,1;
 /* 2007-01-18 : Converted, N.Otuka. Converted to EXFOR E1243 */
 /* Related references 
    - H.Hirabayashi et al., JPJ, 51(1982)3098.
    Reference for monitor. See also NRDF D0962 DATA 1.
 PHQ=XSECTN;
 /* Additional results shown but not compiled
    - Charge distribution (Shown in Fig.2 in reference)
    - Mass distribution (Shown in Fig.3 in reference)
 ENR=NAT;
 CHM=ELM;
 PHYS-FORM=SLD;
 POL-TGT=0%;
 ALGN-TGT=0%;
 ACC=SYN;
 INST-ACC=2JPNKEK;
 INC-ENGY-LAB-RANGE=12GEV;
 POL-PRJ=0%;
 DET-PARTCL=GAMMA'3';
 /* '3' Decay data not given */
 COINC=NO;
 ANT-COINC=NO;
 DET-SYS=GE(LI)'4';
 /* '4' For gamma-ray spectroscopy */
 /* Experimental Method:
    - Stacked target irradiation (Total thickness of 0.5 g/cm2)
    - Activation (Irradiation for 10 min)
    - Gamma ray spectrometry (Performed during 3 months starting
      about a few hours after the end of irradiation)
 /* By authors: Detection of nuclides with lifetimes shorter than about
    one hour are precluded. */
 RCT=TI(P,X)X'8';
 /* '8' See DATA section for atomic number (Z) and mass number (A)
        of products */
 THK-TGT=11.0MG/CM**2;
 MONTR-RCT=/ 27AL(P,X)24NA /;
 /*===================================================================*/
 /* Descriptive Parameters                                            */
 /*===================================================================*/
 \\DATA,1;
 INC-ENGY-LAB=12GEV;
 TOT-ERR=X%'5';
 /* '5' Uncertainty in detection efficiency of gamma rays and
        statistical errors for photopeak yields (Uncertainty in beam
        intensity calibration is not included.) */
 SYS-ERR=(10%'6',15%'7');
 /* '6' Uncertainty in beam intensity calibration */
 /* '7' Maximum uncertainty in detection efficiency (15% below 200
        keV, 5% above 400 keV) */
 DATA1=8.1MB'9';
 /* '9' Used for calibration of the beam intensity monitoring
        system */
 DELTA-DATA1=0.9MB;
 /*===================================================================*/
 /* Data Table                                                        */
 /*===================================================================*/
 \DATA;
 Z A ISOMER SIGMA',10' DELTA-SIGMA''
 (NODIM) (NODIM) (NODIM) (MB) (MB)
 4. 7 X 7.90 +-0.43
 16. 38 X 0.11 +-0.01
 17. 39 X 0.68 +-0.05
 19. 42 X 6.73 +-0.34
 21. 44 0 6.90 +-0.36
 21. 44 1 2.73 +-0.14
 21. 46 X 18.4 +-0.93
 21. 48 X 1.59 +-0.08
 \END;
 /*===================================================================*/