/*===================================================================*/ /* NRDF D1251 Data No.1 */ /*===================================================================*/ /* Bibliography */ /*===================================================================*/ \\BIB,1; D#=D1251; TITLE=/ Nuclear reactions of Ti, Fe, Co, Ni, Cu, and Zn by 500-MeV protons /; ATH=(Y.ASANO'1', S.MORI'1', M.SAKANO'1', K.KATOH'2', K.KONDO'2', M.NOGUCHI'2'); INST-ATH=(2JPNTSU'1', 2JPNKEK'2'); /* '1' Institute of Applied Physics */ REF=JPJ; VLP=60(1991)107; RCTS=(TI(P,X)X, FE(P,X)X, 59CO(P,X)X, NI(P,X)X, CU(P,X)X, ZN(P,X)X); PHQS=XSECTN; /*===================================================================*/ /* Experimental Conditions */ /*===================================================================*/ \\EXP,1; /* 2007-01-18 : Converted, N.Otuka. Converted to EXFOR E1251 */ /* Related references - T.Asano et al., PR/C, 28(1983)1718. (Cross section ratio of present data to this reference (at 12 GeV) discussed). See also NRDF D1243. PHQ=XSECTN; /* Additional results shown but not compiled - Mass distribution (Shown in Fig.1 and 3 in reference) - Charge distribution (Shown in Fig.2 in reference) ENR=NAT'3'; /* '3' noen */ CHM=ELM; PHYS-FORM=SLD; POL-TGT=0%; ALGN-TGT=0%; ACC=SYN; INST-ACC=2JPNKEK; INC-ENGY-LAB-RANGE=500MEV; POL-PRJ=0%; DET-PARTCL=GAMMA'4'; /* '4' Decay data not given */ COINC=NO; ANT-COINC=NO; DET-SYS=GE(LI)'5'; /* '5' To measure gamma rays */ /* Experimental Method: - Stacked target irradiation (Stack of thin metal foils of 14 elements) - Activation (Irradiated for 3 min) - Gamma ray spectrometry (Measured about 14 spectra during 7 months) /* By authors: Measurements of short-lived nuclides with lifetimes shorter than a few hours could not be made. */ RCT=TI(P,X)X'9'; /* '9' See DATA section for atomic number (Z) and mass number (A) of products */ THK-TGT=10.7MG/CM**2; /*===================================================================*/ /* Descriptive Parameters */ /*===================================================================*/ \\DATA,1; INC-ENGY-LAB=500MEV; TOT-ERR=X%'6'; /* '6' Uncertainties in detection efficiency of gamma rays and statistical uncertainty for photo-yield (Uncertainties in beam intensity calibration are not included.) */ SYS-ERR=(10%'7',15%'8'); /* '7' Uncertainty in beam intensity calibration */ /* '8' Maximum uncertainty in detection efficiency (15% below 200 keV, 10% at 200-400 keV, 5% above 400 keV) */ /*===================================================================*/ /* Data Table */ /*===================================================================*/ \DATA; Z A ISOMER SIGMA'10' DELTA-SIGMA'10' (NODIM) (NODIM) (NODIM) (MB) (MB) 4. 7 X 1.42 +-0.09 17. 39 X 0.54 +-0.11 19. 42 X 7.77 +-0.68 21. 44 0 8.76 +-0.46 21. 44 1 4.84 +-0.27 21. 46 X 21.7 +-1.10 21. 48 X 1.53 +-0.11 \END; /*===================================================================*/ |