/*===================================================================*/ /* NRDF D1870 Data No.1 */ /*===================================================================*/ /* Bibliography */ /*===================================================================*/ \\BIB,1; D#=D1870; TITLE=/ On the neutrons from the 14N(d,n)15O reaction - II /; PURPOSE=/ To extend the measured angular range of our previous work on 14N(d,n)15O reaction to the more backward direction /; ATH=(I.NONAKA'1', S.MORITA'1', N.KAWAI'1', T.ISHIMATSU'1', K.TAKESHITA'1', Y.NAKAJIMA'1', N.TAKANO'1'); INST-ATH=(2JPNKYU'1'); /* '1' Department of Physics, Faculty of Science */ REF=JPJ; VLP=12(1957)841; RCTS=(2H(D,N)3HE, 14N(D,N)15O); PHQS=(ANGL-DSTRN, XSECTN); /*===================================================================*/ /* Experimental Conditions */ /*===================================================================*/ \\EXP,1; /* 2004-02-19 : Compiled, Sr + On */ /* Related references - J.L.Fowler et al., RMP, 28(1956)103. Reference for monitor (Angular distribution for 2H(d,n)3He given in Fig.16, p112 of this reference) CHM=X'2'; /* '2' Deuterium gas mixed to nitrogen gas */ PHYS-FORM=GAS; THK-TGT=XMG/CM**2'3'; /* '3' Pressures of deuterium gas and nitrogen gas are 4.3 cmHg and 23.2 cmHg, respectively. */ POL-TGT=0%; ALGN-TGT=0%; ACC=VDG; INST-ACC=2JPNKYU; INC-ENGY-LAB=[1.96MEV'4'; /* '4' considering the energy loss of 190 keV in the nickel foil (1.6mg/cm**2 thick) at the entrance of target chamber and that of 320 keV in target gas */ BEAM-INTNSTY=1UA'5'; /* '5' average value */ POL-PRJ=0%; DET-PARTCL=N; COINC=NO; ANT-COINC=NO; DET-SYS=PLATE'6'; /* '6' Sakura NR-MI nuclear plates, 200 micron emulsion thickness used to detect neutrons */ /* 2006-10-05 : Altered, Is. Re-digitized */ RCT=2H(D,N)3HE; PHQ=ANGL-DSTRN; MONTR-RCT=/ 2H(D,N)3HE /; /*===================================================================*/ /* Descriptive Parameters */ /*===================================================================*/ \\DATA,1; INC-ENGY-LAB=[1.96MEV'7'; /* '7' considering the energy loss of 190 keV in the nickel foil (1.6mg/cm**2 thick) at the entrance of target chamber and that of 320 keV in target gas */ /*===================================================================*/ /* Data Table */ /*===================================================================*/ \DATA; THTC DSIGMA/DOMEGA DELTA-DSIGMA/DOMEGA'8' (DEG) (MB/SR) (MB/SR) 1.919E+01 2.426E+01 +-1.647E+00 3.734E+01 1.535E+01 +-1.353E+00 5.405E+01 7.019E+00 +-7.647E-01 7.099E+01 7.808E+00 +-8.823E-01 8.799E+01 7.303E+00 +-8.823E-01 1.033E+02 5.560E+00 +-7.058E-01 1.178E+02 5.875E+00 +-8.240E-01 1.315E+02 7.660E+00 +-9.999E-01 1.447E+02 1.280E+01 +-1.412E+00 1.568E+02 1.658E+01 +-1.588E+00 1.674E+02 2.377E+01 +-2.000E+00 \END; /*===================================================================*/ |