/*===================================================================*/ /* NRDF D1849 Data No.10 */ /*===================================================================*/ /* Bibliography */ /*===================================================================*/ \\BIB,10; D#=D1849; TITLE=/Some evidence for neutron pick-up from the interior core through the (p,d) reaction/; ATH=(T.ISHIMATSU'1', S.HAYASHIBE'1', N.KAWAMURA'1', T.AWAYA'2', H.OHMURA'2', Y.NAKAJIMA'3', S.MITARAI'3'); INST-ATH=(2JPNTOH'1', 2JPNTOK'2', 2JPNKYU'3'); /* '1' Department of Physics */ /* '2' Department of Physics */ /* '3' Department of Physics */ REF=NP/A; VLP=185(1972)273; RCTS=(100MO(P,D)99MO, 94MO(P,D)93MO, 98MO(P,D)97MO); PHQS=ANGL-DSTRN; /*===================================================================*/ /* Experimental Conditions */ /*===================================================================*/ \\EXP,10; /* 2003-10-31 : Converted, Data converted from EXFOR O0586 */ PHQ=ANGL-DSTRN; CHM=ELM; PHYS-FORM=SLD'4'; /* '4' Metallic foils */ POL-TGT=0%; ALGN-TGT=0%; ACC=SYNCYC; INST-ACC=2JPNINS; INC-ENGY-LAB=52MEV; POL-PRJ=0%; DET-PARTCL=D; COINC=NO; ANT-COINC=NO; DET-SYS=(MAG'5',PROP-CNTR'6',PLST-SCT); /* '5' Broad-range magnetic spectrometer [K.Yagi et al., Nucl. Instr. 52(1967)29] */ /* '6' 200 proportional counters along the focal plane followed by a plastic scintillation counter with 6 phototubes */ /* Experimental Method: - Pulse-height discrimination (Aluminium foils placed in tront of proportional counters and a pulse-height discriminator for the outputs from the scintillation counters allowed the elimination of triton backgrounds from deuteron spectra.) RCT=98MO(P,D)97MO; ENR=97.0%; THK-TGT=3.12MG/CM**2; /*===================================================================*/ /* Descriptive Parameters */ /*===================================================================*/ \\DATA,10; INC-ENGY-LAB=52MEV; SYS-ERR=(10%'49',X%'50'); /* '49' Uncertainty in the solid angle of spectrometer */ /* '50' Uncertainties in the absolute cross sections are estimated to be less than +-20%. */ EMT=D; RSD=97MO; EXC-ENGY=1.01MEV; DELTA-EXC-ENGY=0.02MEV; J-PTY=7/2+; DELTA-THTL=0.23DEG'51'; /* '51' Data-point reader uncertainty */ DELTA-DSIGMA/DOMEGA=1.6%'52'; /* '52' Data-point reader uncertainty */ /*===================================================================*/ /* Data Table */ /*===================================================================*/ \DATA; THTL DSIGMA/DOMEGA DELTA-DSIGMA/DOMEGA'53' (DEG) (MB/SR) (%) 4.97 0.252 +-11. 7.54 0.257 +-9. 10.25 0.24 +-17. 12.63 0.22 +-11. 15.17 0.199 +-11. 17.99 0.134 +-22. 20.22 0.125 +-14. 22.58 0.098 +-11. 25.03 0.051 +-18. 27.92 0.052 +-17. 31.05 0.034 +-21. 33.95 0.039 +-18. 36.78 0.028 +-18. 39.78 0.022 +-18. 42.61 0.0165 +-17. 45.72 0.025 +-16. 48.55 0.019 +-21. 52.65 0.0125 +-21. 56.92 0.0092 +-14. \END; /*===================================================================*/ |