DARPE: Search Results
 /*===================================================================*/
 /* NRDF D1927 Data No.10                                             */
 /*===================================================================*/
 /* Bibliography                                                      */
 /*===================================================================*/
 \\BIB,10;
 D#=D1927;
 TITLE=/ Experimental studies on excitation functions of the
         proton-induced activation reactions on silver /;
 PURPOSE=/ To present the cross-section measurement for Ag-p reaction
           in the enegy range 11-80 MeV. /;
 ATH=(M.S.UDDIN'1', M.HAGIWARA'1', M.BABA'1', F.TARKANYI'2',
      F.DITROI'2');
 INST-ATH=(2JPNTOH'1', 3HUNDEB'2');
      /* '1' Cyclotron and Radioisotope Center */
 REF=ARI;
 VLP=62(2005)533;
 /* Secondary reference 
    - UDDIN, Private communication(2005)
 RCTS=(AG(P,X)103PD, AG(P,X)101PD, AG(P,X)100PD, AG(P,X)99RH,
       AG(P,X)100RH, AG(P,X)101RH, AG(P,X)102RH, AG(P,X)105RH,
       AG(P,X)97RU, AG(P,X)105AG, AG(P,X)106AG);
 PHQS=XSECTN;
 /*===================================================================*/
 /* Experimental Conditions                                           */
 /*===================================================================*/
 \\EXP,10;
 /* 2005-06-29 : Compiled, Tk + On. */
 PHQ=XSECTN;
 ENR=NAT;
 CHM=ELM;
 PHYS-FORM=SLD;
 THK-TGT=XMG/CM**2'3';
 /* '3' 50 and 300 micrometer thick */
 POL-TGT=0%;
 ALGN-TGT=0%;
 ACC=CYC'4';
 /* '4' Isochronous cyclotron, AVF cyclotron */
 INST-ACC=2JPNTOH'5';
 /* '5' Cyclotron and Radioisotope Center */
 POL-PRJ=0%;
 COINC=NO;
 ANT-COINC=NO;
 DET-SYS=HPGE'6';
 /* '6' To measure activities in silver target and monitors */
 /* Experimental Method:
    - Activation ( Irradiated separately with 50, 70 and 80 MeV
      proton beam)
    - Stacked target irradiation (Three stacks containing high-purity
      thin silver foils)
    - Gamma ray spectrometry (Measurement started 1 day after the end
      of bombardment)
 /* Related references 
    - Y.N.Shubin et al., IAEA-NDS-, 204(1998).
    Reference with which data agree (Show good consistency in shape
    with the present data)
 RCT=AG(P,X)105AG;
 DET-PARTCL=GAMMA'41';
 /* '41' Delayed gamma from 105Ag (ground state) */
 /*===================================================================*/
 /* Descriptive Parameters                                            */
 /*===================================================================*/
 \\DATA,10;
 TOT-ERR=X%'7';
 /* '7' Uncertainty estimated from the uncertaintiies of the flux,
        counting area and detector efficiency */
 SYS-ERR=(5%'8',3%'9');
 /* '8' Upper limit of uncertainty in monitor flux (2.54-5%) */
 /* '9' Upper limit of uncertainty in efficiency calibration of
        gamma-ray (1-3%) */
 STATIST-ERR=22%'10';
 /* '10' Upper limit of statistical uncertainty (0.8-22%) */
 ENGY-GAMMA=(280.44KEV'42',344.52KEV'43');
 INTNSTY-GAMMA=(0.302'42',0.414'43');
 HALF-LIFE=(41.29DAY'42',41.29DAY'43');
 /* '42' Delayed gamma from 105Ag (ground state) */
 /* '43' Delayed gamma from 105Ag (ground state) */
 /*===================================================================*/
 /* Data Table                                                        */
 /*===================================================================*/
 \DATA;
 INC-ENGY-LAB XSECTN'44' DELTA-XSECTN'44'
 (MEV) (MB) (MB)
 11.36 0.15 +-0.01
 23.10 33.07 +-1.48
 29.32 333.09 +-19.70
 30.26 390.21 +-16.10
 33.29 424.01 +-16.90
 36.79 422.40 +-17.80
 38.57 371.12 +-12.3
 42.14 288.56 +-12.0
 42.70 274.52 +-11.40
 46.30 231.45 +-9.12
 47.26 220.04 +-10.90
 48.15 231.45 +-9.75
 50.91 260.46 +-11.00
 53.12 282.57 +-11.70
 55.03 304.96 +-13.80
 57.78 310.92 +-14.00
 61.89 316.78 +-14.30
 63.35 315.00 +-18.40
 64.98 307.79 +-14.00
 68.61 280.12 +-16.70
 73.40 246.72 +-14.80
 78.12 228.97 +-13.70
 \END;
 /*===================================================================*/