DARPE: Search Results
 /*===================================================================*/
 /* NRDF D1968 Data No.10                                             */
 /*===================================================================*/
 /* Bibliography                                                      */
 /*===================================================================*/
 \\BIB,10;
 D#=D1968;
 TITLE=/ Excitation functions of Ge(p,xnyp) reactions and production
         of 68Ge /;
 PURPOSE=/ To measure cross sections for the Ge(p,xn)As, (p,pxn)Ge
           and (p,alphapxn)Zn reactions in the proton energy range of
           19-64 MeV. /;
 ATH=(T.HORIGUCHI'1', H.KUMAHORA'1', H.INOUE'1', Y.YOSHIZAWA'1');
 INST-ATH=(2JPNHIR'1');
      /* '1' Facalty of Science */
 REF=ARI;
 VLP=34(1983)1531;
 RCTS=(GE(P,X)71AS, GE(P,X)72AS, GE(P,X)73AS, GE(P,X)74AS,
       GE(P,X)68GE, GE(P,X)69GE, GE(P,X)66GA, GE(P,X)67GA,
       GE(P,X)65ZN);
 PHQS=(XSECTN, TTY);
 /*===================================================================*/
 /* Experimental Conditions                                           */
 /*===================================================================*/
 \\EXP,10;
 /* 2006-06-28 : Compiled, Tk + On */
 ENR=NAT;
 CHM=ELM;
 PHYS-FORM=SLD;
 THK-TGT=107MG/CM**2;
 POL-TGT=0%;
 ALGN-TGT=0%;
 ACC=CYC'2';
 /* '2' Isochronous cyclotron, AVF cyclotron */
 INST-ACC=2JPNRCN;
 INC-ENGY-LAB=65MEV;
 ERS-PRJ=0.5%'3';
 /* '3' Maximum value */
 BEAM-INTNSTY=1UA;
 POL-PRJ=0%;
 COINC=NO;
 ANT-COINC=NO;
 DET-SYS=GE(LI)'4';
 /* '4' To measure gamma rays from product nuclei */
 /* Experimental Method:
    - Activation (Irradiated for 1-2 hour)
    - Stacked target irradiation
    - Gamma ray spectrometry (Measured 40 hour after the end of
      irradiation for short-lived nuclei (66As, 67As, 68As, 69As, 70As,
      66Ge, 67Ge, 65Ga, 68Ga, 70Ga) and 1 month for long-lived nuclei
      (73As, 74As, 68Ge, 65Zn))
 /* No description of cumulative production and isomeric transition in
    references */
 RCT=GE(P,X)68GE;
 PHQ=TTY;
 /*===================================================================*/
 /* Descriptive Parameters                                            */
 /*===================================================================*/
 \\DATA,10;
 INC-ENGY-LAB=65MEV;
 TOT-ERR=16%'5';
 /* '5' Maximum overaluncertainty (11-16%) */
 SYS-ERR=(2%'6',10%'7',3%'8',11%'9');
 /* '6' Uncertainty in target thickness */
 /* '7' Uncertainty in proton beam current (relatively 2% and
        absolutely 10%) */
 /* '8' Uncertainty in detector efficiency */
 /* '9' Maximum uncertainty in gamma-ray intensities per decay
        (0.2-11%) */
 STATIST-ERR=3%'10';
 /* '10' Maximum uncertainty in gamma-ray peak areas (0.1-3%) */
 /*===================================================================*/
 /* Data Table                                                        */
 /*===================================================================*/
 \DATA;
 INC-ENGY-LAB SIGMA
 (MEV) (UCI/UA/HOUR)
 64 48
 \END;
 /*===================================================================*/