/*===================================================================*/ /* NRDF D1849 Data No.11 */ /*===================================================================*/ /* Bibliography */ /*===================================================================*/ \\BIB,11; D#=D1849; TITLE=/Some evidence for neutron pick-up from the interior core through the (p,d) reaction/; ATH=(T.ISHIMATSU'1', S.HAYASHIBE'1', N.KAWAMURA'1', T.AWAYA'2', H.OHMURA'2', Y.NAKAJIMA'3', S.MITARAI'3'); INST-ATH=(2JPNTOH'1', 2JPNTOK'2', 2JPNKYU'3'); /* '1' Department of Physics */ /* '2' Department of Physics */ /* '3' Department of Physics */ REF=NP/A; VLP=185(1972)273; RCTS=(100MO(P,D)99MO, 94MO(P,D)93MO, 98MO(P,D)97MO); PHQS=ANGL-DSTRN; /*===================================================================*/ /* Experimental Conditions */ /*===================================================================*/ \\EXP,11; /* 2003-10-31 : Converted, Data converted from EXFOR O0586 */ PHQ=ANGL-DSTRN; CHM=ELM; PHYS-FORM=SLD'4'; /* '4' Metallic foils */ POL-TGT=0%; ALGN-TGT=0%; ACC=SYNCYC; INST-ACC=2JPNINS; INC-ENGY-LAB=52MEV; POL-PRJ=0%; DET-PARTCL=D; COINC=NO; ANT-COINC=NO; DET-SYS=(MAG'5',PROP-CNTR'6',PLST-SCT); /* '5' Broad-range magnetic spectrometer [K.Yagi et al., Nucl. Instr. 52(1967)29] */ /* '6' 200 proportional counters along the focal plane followed by a plastic scintillation counter with 6 phototubes */ /* Experimental Method: - Pulse-height discrimination (Aluminium foils placed in tront of proportional counters and a pulse-height discriminator for the outputs from the scintillation counters allowed the elimination of triton backgrounds from deuteron spectra.) RCT=94MO(P,D)93MO; ENR=93.9%; THK-TGT=2.92MG/CM**2; /*===================================================================*/ /* Descriptive Parameters */ /*===================================================================*/ \\DATA,11; INC-ENGY-LAB=52MEV; SYS-ERR=(10%'54',X%'55'); /* '54' Uncertainty in the solid angle of spectrometer */ /* '55' Uncertainties in the absolute cross sections are estimated to be less than +-20%. */ EMT=D; RSD=93MO; EXC-ENGY=3.18MEV; DELTA-EXC-ENGY=0.02MEV; J-PTY=3/2-; DELTA-THTL=0.23DEG'56'; /* '56' Data-point reader uncertainty */ DELTA-DSIGMA/DOMEGA=1.6%'57'; /* '57' Data-point reader uncertainty */ /*===================================================================*/ /* Data Table */ /*===================================================================*/ \DATA; THTL DSIGMA/DOMEGA DELTA-DSIGMA/DOMEGA'58' (DEG) (MB/SR) (%) 4.63 2.06 +-X 6.89 2.71 +-X 9.61 2.29 +-X 12.16 1.546 +-X 14.7 0.958 +-X 17.25 0.728 +-2.5 19.83 0.809 +-1.8 21.76 0.879 +-X 24.16 0.761 +-X 27.5 0.444 +-1.8 30.2 0.247 +-1.8 33.58 0.317 +-X 36.15 0.321 +-3. 39.36 0.32 +-2.8 42.72 0.255 +-4. 45.43 0.174 +-5. 48.62 0.116 +-5. 52.79 0.117 +-9. 56.64 0.106 +-5. \END; /*===================================================================*/ |