DARPE: Search Results
 /*===================================================================*/
 /* NRDF D1952 Data No.11                                             */
 /*===================================================================*/
 /* Bibliography                                                      */
 /*===================================================================*/
 \\BIB,11;
 D#=D1952;
 TITLE=/ (p,xn), (p,pxn), and (p,2pxn) reactions for medium-mass
         nuclei at 12 GeV /;
 PURPOSE=/ To determine cross section for (p,x) reactions of Ti, Fe,
           Co, Ni, Cu and Zn isotopes at 12 GeV from spallation yield
           data /;
 ATH=(T.ASANO'1', Y.ASANO'1', Y.IGUCHI'1', H.KUDO'1', S.MORI'1',
      M.NOGUCHI'1', Y.TAKADA'1', H.HIRABAYASHI'2', H.IKEDA'2',
      K.KATOH'2', K.KONDO'2', M.TAKASAKI'2', T.TOMINAKA'2',
      A.YAMAMOTO'2');
 INST-ATH=(2JPNTSU'1', 2JPNKEK'2');
      /* '1' Institute of Applied Physics */
 REF=PR/C;
 VLP=28(1983)1840;
 RCTS=(TI(P,X)X, FE(P,X)X, 59CO(P,X)X, NI(P,X)X, CU(P,X)X,
       ZN(P,X)65ZN, 48TI(P,N)48V, 56FE(P,X)X, 57FE(P,N)57CO,
       65CU(P,X)X, 63CU(P,2*N)62ZN);
 PHQS=XSECTN;
 /*===================================================================*/
 /* Experimental Conditions                                           */
 /*===================================================================*/
 \\EXP,11;
 /* 2006-02-06 : Compiled+Checked, C.Kurokawa + N.Otuka */
 PHQ=XSECTN;
 ENR=NAT;
 CHM=ELM;
 PHYS-FORM=SLD;
 POL-TGT=0%;
 ALGN-TGT=0%;
 ACC=SYN;
 INST-ACC=2JPNKEK;
 INC-ENGY-LAB-RANGE=12GEV;
 POL-PRJ=0%;
 DET-PARTCL=GAMMA;
 COINC=NO;
 ANT-COINC=NO;
 DET-SYS=GE(LI)'3';
 /* '3' To measure gamma-yields of unstable products */
 /* Experimental Method:
    - Activation
    - Gamma ray spectrometry
 /* Comment by authors: Reactions include all reactions associated with
    pion production if the baryon number and charge are consistent with
    those of the defined reactions. */
 RCT=63CU(P,2*N)62ZN;
 THK-TGT=9.06MG/CM**2;
 /*===================================================================*/
 /* Descriptive Parameters                                            */
 /*===================================================================*/
 \\DATA,11;
 INC-ENGY-LAB=12GEV;
 SYS-ERR=[10%'4';
 /* '4' Uncertainty in beam intensity calibration */
 /*===================================================================*/
 /* Data Table                                                        */
 /*===================================================================*/
 \DATA;
 SIGMA DELTA-SIGMA'22'
 (MB) (MB)
 0.30 +-0.03
 \END;
 /*===================================================================*/