/*===================================================================*/ /* NRDF D1769 Data No.117 */ /*===================================================================*/ /* Bibliography */ /*===================================================================*/ \\BIB,117; D#=D1769; TITLE=/ Double-differential cross sections for the neutron production from heavy-ion reactions at energies E/A = 290-600 MeV /; PURPOSE=/ Systematic measurements of neutron-production cross sections from C, Ne, and Ar projectiles having E/A = 290-600 MeV on C, Cu, and Pb targets. /; ATH=(Y.IWATA'1', T.MURAKAMI'1', H.SATO'2', H.IWASE'2', T.NAKAMURA'2', T.KUROSAWA'2', L.HEILBRONN'3', R.M.RONNINGEN'4', K.IEKI'5', Y.TOZAWA'5', K.NIITA'6'); INST-ATH=(2JPNIRS'1', 2JPNTOH'2', 1USABRK'3', 1USAMSU'4', 2JPNRIK'5', 2JPNJPN'6'); /* '1' Department of Accelerator Physics and Engineering */ /* '2' Cyclotron and Radioisotope Center */ /* '4' National Superconducting Cyclotron Laboratory */ /* '5' Department of Physics */ /* '6' Research Organization for Information Science and Technology, Tokai, Naka, Ibaraki */ REF=PR/C; VLP=64(2001)054609; RCTS=(C(12C,N)X, CU(12C,N)X, PB(12C,N)X, C(20NE,N)X, CU(20NE,N)X, PB(20NE,N)X, C(40AR,N)X, CU(40AR,N)X, PB(40AR,N)X); PHQS=(ENGY-SPEC, ANGL-DSTRN, XSECTN, TOT-XSECTN, MLT); /*===================================================================*/ /* Experimental Conditions */ /*===================================================================*/ \\EXP,117; /* 2002-08-01 : Compiled, Am + Sr + On */ /* 2006-07-25 : Altered, On. Heading of data error corrected. Systematic uncertainties added. */ RTY=HEAVY-ION-RCT; ENR=NAT; CHM=ELM; PHYS-FORM=SLD; BAC=X; POL-TGT=0%; ALGN-TGT=0%; ACC=SYN'7'; /* '7' Heavy Ion Medical Accelerator in Chiba (HIMAC) facility INST-ACC=2JPNIRS; BEAM-INTNSTY=XMA'8'; /* '8' A few times 10e4-10e5 particles per pulse */ POL-PRJ=0%; DET-PARTCL=N; COINC=NO; ANT-COINC=NO; DET-SYS=(SCT'9',SCT'10',TOF); /* '9' NE102A plastic scintillator */ /* '10' NE213 liquid scintillator */ ERS-DET=XKEV'11'; /* '11' The energy resolutions are shown in Table I in reference. /* Experimental Method: - Time-of-flight RCT=CU(40AR,N)X; PHQ=ENGY-SPEC; THK-TGT=1790MG/CM**2; INC-ENGY-LAB=560.0MEV/A; ANL=X'361'; /* '361' Moving-source model, QMD and HIC */ /*===================================================================*/ /* Descriptive Parameters */ /*===================================================================*/ \\DATA,117; SYS-ERR=10%'12'; /* '12' Uncertainty in detection efficiency */ INC-ENGY-LAB=560.0MEV/A; SYS-ERR=2.5%'362'; /* '362' Uncertainty in target thickness */ THTL=40DEG; /*===================================================================*/ /* Data Table */ /*===================================================================*/ \DATA; ENGY-EMT-LAB DSIGMA/DOMEGA/DE DELTA-DSIGMA/DOMEGA/DE'363' (MEV) (MB/SR/MEV) (MB/SR/MEV) 5 357 +-40 6 270 +-30 7 242 +-30 8 247 +-29 9 128 +-29 10 165 +-24 20 81.0 +-5.0 50 63.3 +-4.5 80 53.8 +-4.1 110 44.4 +-3.8 150 43.1 +-3.5 190 36.0 +-2.9 230 27.9 +-2.5 280 24.8 +-2.1 330 19.2 +-1.9 380 16.5 +-1.5 430 8.88 +-1.44 490 8.54 +-0.99 550 4.12 +-0.90 630 2.63 +-0.63 750 1.07 +-0.41 910 1.26 +-0.24 1110 0.366 +-0.128 1310 0.114 +-0.093 1510 0.137 +-0.082 1710 0.00e+00 +-8.84e-02 \END; /*===================================================================*/ |