DARPE: Search Results
 /*===================================================================*/
 /* NRDF D1849 Data No.12                                             */
 /*===================================================================*/
 /* Bibliography                                                      */
 /*===================================================================*/
 \\BIB,12;
 D#=D1849;
 TITLE=/Some evidence for neutron pick-up from the interior core
        through the (p,d) reaction/;
 ATH=(T.ISHIMATSU'1', S.HAYASHIBE'1', N.KAWAMURA'1', T.AWAYA'2',
      H.OHMURA'2', Y.NAKAJIMA'3', S.MITARAI'3');
 INST-ATH=(2JPNTOH'1', 2JPNTOK'2', 2JPNKYU'3');
      /* '1' Department of Physics */
      /* '2' Department of Physics */
      /* '3' Department of Physics */
 REF=NP/A;
 VLP=185(1972)273;
 RCTS=(100MO(P,D)99MO, 94MO(P,D)93MO, 98MO(P,D)97MO);
 PHQS=ANGL-DSTRN;
 /*===================================================================*/
 /* Experimental Conditions                                           */
 /*===================================================================*/
 \\EXP,12;
 /* 2003-10-31 : Converted, Data converted from EXFOR O0586 */
 PHQ=ANGL-DSTRN;
 CHM=ELM;
 PHYS-FORM=SLD'4';
 /* '4' Metallic foils */
 POL-TGT=0%;
 ALGN-TGT=0%;
 ACC=SYNCYC;
 INST-ACC=2JPNINS;
 INC-ENGY-LAB=52MEV;
 POL-PRJ=0%;
 DET-PARTCL=D;
 COINC=NO;
 ANT-COINC=NO;
 DET-SYS=(MAG'5',PROP-CNTR'6',PLST-SCT);
 /* '5' Broad-range magnetic spectrometer [K.Yagi et al., Nucl.
        Instr. 52(1967)29] */
 /* '6' 200 proportional counters along the focal plane followed by
        a plastic scintillation counter with 6 phototubes */
 /* Experimental Method:
    - Pulse-height discrimination (Aluminium foils placed in tront of
      proportional counters and a pulse-height discriminator for the
      outputs from the scintillation counters allowed the elimination
      of triton backgrounds from deuteron spectra.)
 RCT=94MO(P,D)93MO;
 ENR=93.9%;
 THK-TGT=2.92MG/CM**2;
 /*===================================================================*/
 /* Descriptive Parameters                                            */
 /*===================================================================*/
 \\DATA,12;
 INC-ENGY-LAB=52MEV;
 SYS-ERR=(10%'59',X%'60');
 /* '59' Uncertainty in the solid angle of spectrometer */
 /* '60' Uncertainties in the absolute cross sections are
         estimated to be less than +-20%. */
 EMT=D;
 RSD=93MO;
 EXC-ENGY=2.93MEV;
 DELTA-EXC-ENGY=0.02MEV;
 J-PTY=1/2-;
 DELTA-THTL=0.23DEG'61';
 /* '61' Data-point reader uncertainty */
 DELTA-DSIGMA/DOMEGA=1.6%'62';
 /* '62' Data-point reader uncertainty */
 /*===================================================================*/
 /* Data Table                                                        */
 /*===================================================================*/
 \DATA;
 THTL DSIGMA/DOMEGA DELTA-DSIGMA/DOMEGA'63'
 (DEG) (MB/SR) (%)
 4.59           0.94           +-X
 7.16           1.01           +-5.
 9.72           0.85           +-9.
 12.59          0.655          +-4.
 14.34          0.436          +-2.1
 17.05          0.32           +-9.
 19.62          0.331          +-6.
 22.02          0.315          +-7.
 24.26          0.254          +-8.
 27.45          0.165          +-8.
 30.31          0.1            +-7.
 33.51          0.081          +-7.
 36.55          0.072          +-11.
 39.44          0.072          +-6.
 42.64          0.058          +-12.
 45.82          0.036          +-11.
 48.7           0.0297         +-10.
 52.87          0.0248         +-8.
 56.87          0.022          +-8.
 \END;
 /*===================================================================*/