/*===================================================================*/ /* NRDF D1769 Data No.13 */ /*===================================================================*/ /* Bibliography */ /*===================================================================*/ \\BIB,13; D#=D1769; TITLE=/ Double-differential cross sections for the neutron production from heavy-ion reactions at energies E/A = 290-600 MeV /; PURPOSE=/ Systematic measurements of neutron-production cross sections from C, Ne, and Ar projectiles having E/A = 290-600 MeV on C, Cu, and Pb targets. /; ATH=(Y.IWATA'1', T.MURAKAMI'1', H.SATO'2', H.IWASE'2', T.NAKAMURA'2', T.KUROSAWA'2', L.HEILBRONN'3', R.M.RONNINGEN'4', K.IEKI'5', Y.TOZAWA'5', K.NIITA'6'); INST-ATH=(2JPNIRS'1', 2JPNTOH'2', 1USABRK'3', 1USAMSU'4', 2JPNRIK'5', 2JPNJPN'6'); /* '1' Department of Accelerator Physics and Engineering */ /* '2' Cyclotron and Radioisotope Center */ /* '4' National Superconducting Cyclotron Laboratory */ /* '5' Department of Physics */ /* '6' Research Organization for Information Science and Technology, Tokai, Naka, Ibaraki */ REF=PR/C; VLP=64(2001)054609; RCTS=(C(12C,N)X, CU(12C,N)X, PB(12C,N)X, C(20NE,N)X, CU(20NE,N)X, PB(20NE,N)X, C(40AR,N)X, CU(40AR,N)X, PB(40AR,N)X); PHQS=(ENGY-SPEC, ANGL-DSTRN, XSECTN, TOT-XSECTN, MLT); /*===================================================================*/ /* Experimental Conditions */ /*===================================================================*/ \\EXP,13; /* 2002-08-01 : Compiled, Am + Sr + On */ /* 2006-07-25 : Altered, On. Heading of data error corrected. Systematic uncertainties added. */ RTY=HEAVY-ION-RCT; ENR=NAT; CHM=ELM; PHYS-FORM=SLD; BAC=X; POL-TGT=0%; ALGN-TGT=0%; ACC=SYN'7'; /* '7' Heavy Ion Medical Accelerator in Chiba (HIMAC) facility INST-ACC=2JPNIRS; BEAM-INTNSTY=XMA'8'; /* '8' A few times 10e4-10e5 particles per pulse */ POL-PRJ=0%; DET-PARTCL=N; COINC=NO; ANT-COINC=NO; DET-SYS=(SCT'9',SCT'10',TOF); /* '9' NE102A plastic scintillator */ /* '10' NE213 liquid scintillator */ ERS-DET=XKEV'11'; /* '11' The energy resolutions are shown in Table I in reference. /* Experimental Method: - Time-of-flight RCT=CU(12C,N)X; PHQ=ENGY-SPEC; THK-TGT=4470MG/CM**2; INC-ENGY-LAB=290.0MEV/A; ANL=X'49'; /* '49' Moving-source model, QMD and HIC */ /*===================================================================*/ /* Descriptive Parameters */ /*===================================================================*/ \\DATA,13; SYS-ERR=10%'12'; /* '12' Uncertainty in detection efficiency */ INC-ENGY-LAB=290.0MEV/A; SYS-ERR=2.5%'50'; /* '50' Uncertainty in target thickness */ THTL=60DEG; /*===================================================================*/ /* Data Table */ /*===================================================================*/ \DATA; ENGY-EMT-LAB DSIGMA/DOMEGA/DE DELTA-DSIGMA/DOMEGA/DE'51' (MEV) (MB/SR/MEV) (MB/SR/MEV) 5 35.2 +-5.3 6 23.9 +-4.4 7 19.7 +-4.4 8 18.3 +-3.6 9 16.9 +-2.9 10 12.7 +-3.5 15 6.90 +-0.69 25 4.64 +-0.75 35 3.66 +-0.80 45 3.94 +-0.65 55 3.52 +-0.73 65 4.22 +-0.67 75 3.38 +-0.73 85 3.52 +-0.58 95 2.96 +-0.64 105 2.81 +-0.62 125 3.45 +-0.41 145 1.97 +-0.33 165 1.41 +-0.30 185 0.985 +-0.288 205 0.844 +-0.162 235 0.516 +-0.154 265 0.141 +-0.173 295 0.141 +-0.055 325 0.141 +-0.050 365 -7.04e-02 +-8.46e-02 405 0.00e+00 +-8.70e-02 465 0.00e+00 +-1.48e-02 525 0.00e+00 +-7.07e-03 605 -3.52e-02 +-4.45e-02 725 1.17e-02 +-6.18e-03 885 8.80e-03 +-4.78e-03 1085 7.04e-03 +-4.00e-03 1285 7.04e-03 +-5.04e-03 1485 7.04e-03 +-4.09e-03 1685 7.04e-03 +-4.42e-03 1885 0.00e+00 +-2.21e-03 \END; /*===================================================================*/ |