/*===================================================================*/ /* NRDF D1849 Data No.13 */ /*===================================================================*/ /* Bibliography */ /*===================================================================*/ \\BIB,13; D#=D1849; TITLE=/Some evidence for neutron pick-up from the interior core through the (p,d) reaction/; ATH=(T.ISHIMATSU'1', S.HAYASHIBE'1', N.KAWAMURA'1', T.AWAYA'2', H.OHMURA'2', Y.NAKAJIMA'3', S.MITARAI'3'); INST-ATH=(2JPNTOH'1', 2JPNTOK'2', 2JPNKYU'3'); /* '1' Department of Physics */ /* '2' Department of Physics */ /* '3' Department of Physics */ REF=NP/A; VLP=185(1972)273; RCTS=(100MO(P,D)99MO, 94MO(P,D)93MO, 98MO(P,D)97MO); PHQS=ANGL-DSTRN; /*===================================================================*/ /* Experimental Conditions */ /*===================================================================*/ \\EXP,13; /* 2003-10-31 : Converted, Data converted from EXFOR O0586 */ PHQ=ANGL-DSTRN; CHM=ELM; PHYS-FORM=SLD'4'; /* '4' Metallic foils */ POL-TGT=0%; ALGN-TGT=0%; ACC=SYNCYC; INST-ACC=2JPNINS; INC-ENGY-LAB=52MEV; POL-PRJ=0%; DET-PARTCL=D; COINC=NO; ANT-COINC=NO; DET-SYS=(MAG'5',PROP-CNTR'6',PLST-SCT); /* '5' Broad-range magnetic spectrometer [K.Yagi et al., Nucl. Instr. 52(1967)29] */ /* '6' 200 proportional counters along the focal plane followed by a plastic scintillation counter with 6 phototubes */ /* Experimental Method: - Pulse-height discrimination (Aluminium foils placed in tront of proportional counters and a pulse-height discriminator for the outputs from the scintillation counters allowed the elimination of triton backgrounds from deuteron spectra.) RCT=100MO(P,D)99MO; ENR=95.9%; THK-TGT=3.0MG/CM**2; /*===================================================================*/ /* Descriptive Parameters */ /*===================================================================*/ \\DATA,13; INC-ENGY-LAB=52MEV; SYS-ERR=(10%'64',X%'65'); /* '64' Uncertainty in the solid angle of spectrometer */ /* '65' Uncertainties in the absolute cross sections are estimated to be less than +-20%. */ EMT=D; RSD=99MO; EXC-ENGY=1.92MEV; DELTA-EXC-ENGY=0.02MEV; J-PTY=1/2-; DELTA-THTL=0.23DEG'66'; /* '66' Data-point reader uncertainty */ DELTA-DSIGMA/DOMEGA=1.6%'67'; /* '67' Data-point reader uncertainty */ /*===================================================================*/ /* Data Table */ /*===================================================================*/ \DATA; THTL DSIGMA/DOMEGA DELTA-DSIGMA/DOMEGA'68' (DEG) (MB/SR) (%) 4.96 1.26 +-6. 7.85 1.2 +-8. 10.88 0.91 +-7. 13.43 0.65 +-11. 16.79 0.54 +-11. 19.83 0.4 +-13. 22.55 0.36 +-11. 25.75 0.29 +-14. 30.05 0.158 +-13. 34.05 0.12 +-13. 37.74 0.113 +-13. 42.06 0.085 +-14. 46.21 0.064 +-13. 50.21 0.05 +-14. 54.38 0.044 +-18. \END; /*===================================================================*/ |