DARPE: Search Results
 /*===================================================================*/
 /* NRDF D1965 Data No.13                                             */
 /*===================================================================*/
 /* Bibliography                                                      */
 /*===================================================================*/
 \\BIB,13;
 D#=D1965;
 TITLE=/ Proton activation analysis of trace impurities in purified
         cobalt /;
 ATH=(M.ISSHIKI'1', Y.FUKUDA'1', K.IGAKI'1');
 INST-ATH=(2JPNTOH'1');
      /* '1' Department of Materials Science, Faculty of Engineering
 REF=JRN;
 VLP=82(1984)135;
 RCTS=(48TI(P,N)48V, 52CR(P,N)52MN, 56FE(P,N)56CO, 61NI(P,N)61CU,
       60NI(P,GAMMA)61CU, 63CU(P,N)63ZN, 66ZN(P,N)66GA, 69GA(P,N)69GE,
       72GE(P,N)72AS, 75AS(P,N)75SE, 82SE(P,N)82BR, 90ZR(P,N)90NB,
       93NB(P,N)93MO, 95MO(P,N)95TC, 111CD(P,N)111IN, 122SN(P,N)122SB,
       121SB(P,N)121TE, 130TE(P,N)130I, 206PB(P,N)206BI);
 PHQS=TTY;
 /*===================================================================*/
 /* Experimental Conditions                                           */
 /*===================================================================*/
 \\EXP,13;
 /* 2005-11-22 : Compiled, Am + On */
 PHQ=TTY;
 PHYS-FORM=SLD;
 POL-TGT=0%;
 ALGN-TGT=0%;
 ACC=CYC;
 INST-ACC=2JPNTOH'2';
 /* '2' Cyclotron and Radioisotope Center */
 INC-ENGY-LAB=10.4MEV;
 BEAM-INTNSTY=0.04UA;
 POL-PRJ=0%;
 COINC=NO;
 ANT-COINC=NO;
 DET-SYS=GE(LI)'3';
 /* '3' To measure gamma-ray spectrum */
 /* Experimental Method:
    - Activation (Bombarded for 1-2 hour)
    - Gamma ray spectrometry (Repeated after three different cooling
      times of 1, 15 and 250 hrs)
 /* No description of cumulative production and isomeric transition in
    references */
 RCT=95MO(P,N)95TC;
 CHM=ELM'41';
 /* '41' Purity of 99.9% */
 DET-PARTCL=GAMMA'42';
 /* '42' Delayed gamma from 95Tc (ground state) */
 /*===================================================================*/
 /* Descriptive Parameters                                            */
 /*===================================================================*/
 \\DATA,13;
 TOT-ERR=X%'4';
 /* '4' No uncertainty of quantity measured given */
 ENGY-GAMMA=765.8KEV'43';
 HALF-LIFE=20.01HOUR'43';
 /* '43' Delayed gamma from 95Tc (ground state) via NONe (ground
         state) */
 /*===================================================================*/
 /* Data Table                                                        */
 /*===================================================================*/
 \DATA;
 INC-ENGY-LAB TTY
 (MEV) (UCI/UA/HOUR)
 10.4 210
 \END;
 /*===================================================================*/