DARPE: Search Results
 /*===================================================================*/
 /* NRDF D1370 Data No.14                                             */
 /*===================================================================*/
 /* Bibliography                                                      */
 /*===================================================================*/
 \\BIB,14;
 D#=D1370;
 TITLE=/ Pre-equilibrium process in 3He-induced reactions on 59Co,
         109Ag, 181Ta and 209Bi /;
 ATH=(Y.NAGAME'1', Y.NAKAMURA'2', M.TAKAHASHI'2', K.SUEKI'2',
      H.NAKAHARA'2');
 INST-ATH=(2JPNJAE'1', 2JPNTMU'2');
      /* '1' Department of Radioisotopes */
      /* '2' Department of Chemistry, Faculty of Science */
 REF=NP/A;
 VLP=486(1988)77;
 RCTS=(59CO(3HE,N)61CU, 59CO(3HE,2*N)60CU, 59CO(3HE,2*N,2*P)58CO,
       59CO(3HE,N,ALPHA)57CO, 59CO(3HE,2*N,ALPHA)56CO,
       59CO(3HE,2*P)60CO, 109AG(3HE,N)111IN, 109AG(3HE,2*N)110IN,
       109AG(3HE,3*N)109IN, 109AG(3HE,2*N,P)109CD, 209BI(3HE,N)211AT,
       209BI(3HE,2*N)210AT, 209BI(3HE,3*N)209AT, 209BI(3HE,4*N)208AT,
       209BI(3HE,2*N,ALPHA)206BI, 181TA(3HE,N)183RE);
 PHQS=EXC-FUNCT;
 /*===================================================================*/
 /* Experimental Conditions                                           */
 /*===================================================================*/
 \\EXP,14;
 /* 2006-05-23 : Converted, N.Otuka. Converted to EXFOR E1370 */
 PHQ=EXC-FUNCT;
 CHM=ELM;
 PHYS-FORM=SLD;
 POL-TGT=0%;
 ALGN-TGT=0%;
 ACC=CYC;
 INST-ACC=2JPNIPC;
 BEAM-INTNSTY=[0.5UA;
 POL-PRJ=0%;
 COINC=NO;
 ANT-COINC=NO;
 ANL=PREEQUI-MODEL'3';
 /* '3' Code ALICE /LIVERMORE /85 /300 */
 /* Experimental Method:
    - Stacked target irradiation (Constructed by targets and Al
      catcher foils)
 /* 2006-06-09 : Altered, Is. Re-digitized */
 /* Related references 
    - E.T.Strom, UCRL-, 9372(1960).
    (Compared but no comment by authors)
 RCT=209BI(3HE,4*N)208AT;
 THK-TGT=0.20[0.35MG/CM**2;
 DET-PARTCL=GAMMA'51';
 /* '51' Delayed gamma from 208At */
 DET-SYS=GE(LI)'52';
 /* '52' To measure radioactivities */
 /* Experimental Method:
    - Gamma ray spectrometry
 /*===================================================================*/
 /* Descriptive Parameters                                            */
 /*===================================================================*/
 \\DATA,14;
 SYS-ERR=(2%'4',5%'5',3%'6',20%'7',8%'8');
 /* '4' Uncertainty in current integration with a Faraday cup */
 /* '5' Maximum uncertainty in target thickness (2-5%) */
 /* '6' Uncertainty in detector efficiency */
 /* '7' Maximum uncertainty in gamma- or alpha-ray peak analysis */
 /* '8' Uncertainty in chemical yield */
 ENGY-GAMMA=177KEV'53';
 INTNSTY-GAMMA=0.790'53';
 HALF-LIFE=1.6HOUR'53';
 /* '53' Delayed gamma from 208At */
 /*===================================================================*/
 /* Data Table                                                        */
 /*===================================================================*/
 \DATA;
 INC-ENGY-LAB SIGMA
 (MEV) (MB)
 2.535E+01 1.462E+01
 2.763E+01 9.173E+01
 2.943E+01 2.311E+02
 3.128E+01 3.197E+02
 3.269E+01 4.306E+02
 3.460E+01 4.413E+02
 3.614E+01 3.791E+02
 3.783E+01 3.533E+02
 \END;
 /*===================================================================*/