 /* NRDF D1730 Data No.14                                             */
 /*===================================================================*/
 /* Bibliography                                                      */
 /*===================================================================*/
 \\BIB,14;
 D#=D1730;
 TITLE=/ Tensor polarization of 12C[2+1] in the 16O(13C,12C)17O
         reaction at 50 MeV /;
 ATH=(N.IKEDA'1', F.NAKAMURA'1', K.MIZUUCHI'1', T.SUGIMITSU'1',
      S.TERUYAMA'1', T.OKAMOTO'1', H.FUJITA'2', S.MORINOBU'1');
 INST-ATH=(2JPNKYU'1', 2JPNJPN'2');
      /* '1' Department of Physics */
      /* '2' Daiichi College of Pharamaceutical Sciences, Fukuoka */
 REF=EPJ/A;
 VLP=7(2000)491;
 RCTS=(16O(13C,12C)17O, 16O(13C,13C)16O, 16O(13C,));
 PHQS=(ENGY-SPEC, ANGL-DSTRN, TNSR-ANALPW, OPT-POTL-PARA, SPEC-AMPL);
 /*===================================================================*/
 /* Experimental Conditions                                           */
 /*===================================================================*/
 \\EXP,14;
 /* 2002-10-02 : Converted, On. Data converted to EXFOR E1730 */
 /* 2010-06-16 : Received, Received by e-mail from N.Ikeda */
 ENR=NAT;
 CHM=SI.O;
 PHYS-FORM=SLD;
 THK-TGT=0.0059MG/CM**2'3';
 /* '3' for Oxygen estimated from optical model analysis */
 BAC=C;
 THK-BAC=0.017MG/CM**2'4';
 /* '4' estimated from optical model analysis */
 POL-TGT=0%;
 ALGN-TGT=0%;
 ACC=VDGT;
 INST-ACC=2JPNKYU;
 INC-ENGY-LAB-RANGE=50MEV;
 POL-PRJ=0%;
 ANT-COINC=NO;
 DET-SYS=SI'5';
 /* '5' PSD-E(to detect ejected 12C): 100-micrometer thickness and
        45mmx8mm in area, PSD-R(to detect 17O residues):500-micrometer
        thickness and 45mmx7mm in area */
 ERS-DET=[150KEV'6';
 /* '6' and angular resolution of 0.05deg for
        16O(13C,12C[g.s.])17O[g.s.]. The energy resolution and angular
        resolution of elastic scattering of 50 MeV 13C on gold are
        135keV and 0.03deg, respectively. */
 CALB-DET=/ Calibrated in position and energy using the elastic
            scattering of 13C on gold /;
 MONTR-RCT=/ , Additional single measurements of elastic scattering
             using the PSD-E were carried out from time to time to
             monitor the target thickness. /;
 RCT=16O(13C,12C)17O;
 RTY=STRP;
 PHQ=SPEC-AMPL;
 COINC=NO;
 ANL=DWBA;
 /*===================================================================*/
 /* Descriptive Parameters                                            */
 /*===================================================================*/
 \\DATA,14;
 INC-ENGY-LAB=50MEV;
 /*===================================================================*/
 /* Data Table                                                        */
 /*===================================================================*/
 \DATA;
 SPEC-AMPL'40' SPEC-AMPL'41' FLAG'42'
 (NODIM) (NODIM) (NODIM)
 0.900 0.900 1
 0.800 0.750 2
 0.783 0.783 3
 -0.900 -0.600 4
 X -0.433 5
 X -0.745 6
 X 0.745 7
 X -0.745 8
 X 0.745 9
 \END;
 /*===================================================================*/