DARPE: Search Results
 /*===================================================================*/
 /* NRDF D1849 Data No.14                                             */
 /*===================================================================*/
 /* Bibliography                                                      */
 /*===================================================================*/
 \\BIB,14;
 D#=D1849;
 TITLE=/Some evidence for neutron pick-up from the interior core
        through the (p,d) reaction/;
 ATH=(T.ISHIMATSU'1', S.HAYASHIBE'1', N.KAWAMURA'1', T.AWAYA'2',
      H.OHMURA'2', Y.NAKAJIMA'3', S.MITARAI'3');
 INST-ATH=(2JPNTOH'1', 2JPNTOK'2', 2JPNKYU'3');
      /* '1' Department of Physics */
      /* '2' Department of Physics */
      /* '3' Department of Physics */
 REF=NP/A;
 VLP=185(1972)273;
 RCTS=(100MO(P,D)99MO, 94MO(P,D)93MO, 98MO(P,D)97MO);
 PHQS=ANGL-DSTRN;
 /*===================================================================*/
 /* Experimental Conditions                                           */
 /*===================================================================*/
 \\EXP,14;
 /* 2003-10-31 : Converted, Data converted from EXFOR O0586 */
 PHQ=ANGL-DSTRN;
 CHM=ELM;
 PHYS-FORM=SLD'4';
 /* '4' Metallic foils */
 POL-TGT=0%;
 ALGN-TGT=0%;
 ACC=SYNCYC;
 INST-ACC=2JPNINS;
 INC-ENGY-LAB=52MEV;
 POL-PRJ=0%;
 DET-PARTCL=D;
 COINC=NO;
 ANT-COINC=NO;
 DET-SYS=(MAG'5',PROP-CNTR'6',PLST-SCT);
 /* '5' Broad-range magnetic spectrometer [K.Yagi et al., Nucl.
        Instr. 52(1967)29] */
 /* '6' 200 proportional counters along the focal plane followed by
        a plastic scintillation counter with 6 phototubes */
 /* Experimental Method:
    - Pulse-height discrimination (Aluminium foils placed in tront of
      proportional counters and a pulse-height discriminator for the
      outputs from the scintillation counters allowed the elimination
      of triton backgrounds from deuteron spectra.)
 RCT=98MO(P,D)97MO;
 ENR=97.0%;
 THK-TGT=3.12MG/CM**2;
 /*===================================================================*/
 /* Descriptive Parameters                                            */
 /*===================================================================*/
 \\DATA,14;
 INC-ENGY-LAB=52MEV;
 SYS-ERR=(10%'69',X%'70');
 /* '69' Uncertainty in the solid angle of spectrometer */
 /* '70' Uncertainties in the absolute cross sections are
         estimated to be less than +-20%. */
 EMT=D;
 RSD=97MO;
 EXC-ENGY=1.43MEV;
 DELTA-EXC-ENGY=0.02MEV;
 J-PTY=11/2-;
 DELTA-THTL=0.23DEG'71';
 /* '71' Data-point reader uncertainty */
 DELTA-DSIGMA/DOMEGA=1.6%'72';
 /* '72' Data-point reader uncertainty */
 /*===================================================================*/
 /* Data Table                                                        */
 /*===================================================================*/
 \DATA;
 THTL DSIGMA/DOMEGA DELTA-DSIGMA/DOMEGA'73'
 (DEG) (MB/SR) (%)
 5.08           0.196          +-8.
 7.43           0.258          +-7.
 9.89           0.267          +-7.
 12.53          0.286          +-6.
 15.01          0.318          +-X
 17.63          0.301          +-X
 20.4           0.262          +-2.3
 22.86          0.255          +-X
 25.26          0.1786         +-X
 28.48          0.116          +-6.
 31.36          0.0737         +-6.
 34.43          0.057          +-9.
 37.04          0.051          +-14.
 40.34          0.056          +-9.
 43.08          0.041          +-10.
 45.84          0.0339         +-9.
 48.95          0.031          +-9.
 53.07          0.0352         +-8.
 57.13          0.0261         +-7.