DARPE: Search Results
 /*===================================================================*/
 /* NRDF D1872 Data No.15                                             */
 /*===================================================================*/
 /* Bibliography                                                      */
 /*===================================================================*/
 \\BIB,15;
 D#=D1872;
 TITLE=/ (d,alpha) reactions on 19F, 20Ne, 31P and 32S at 14.7 MeV /;
 ATH=(K.TAKAMATSU'1');
 INST-ATH=(2JPNKTO'1');
      /* '1' Department of Physics, Faculty of Science */
 REF=JPJ;
 VLP=17(1962)896;
 RCTS=(19F(D,ALPHA)17O, 31P(D,ALPHA)29SI, 20NE(D,ALPHA)18F,
       32S(D,ALPHA)30P, 24MG(D,ALPHA)22NA);
 PHQS=(ANGL-DSTRN, XSECTN);
 /*===================================================================*/
 /* Experimental Conditions                                           */
 /*===================================================================*/
 \\EXP,15;
 /* 2004-02-20 : Compiled, Ic + On */
 /* Related references 
    - K.Kimura et al., JPJ, 17(1962)9.
    (Details of beam handling and scattering chamber)
    - T.Yanabu et al., JPJ, 17(1962)914.
    (Details of detecting system)
    - M.el Nadi, PR, 119(1960)242.
    (Two-nucleon picjup process formula used in analysis)
    - H.C.Newns, PPS, 76(1960)489.
    (Two-nucleon picjup process formula used in analysis)
 /* Additional results shown but not compiled
    - Energy distribution (Typical pulse-height spectrum (channel
      number v.s. counts/channel) of alpha particlles are shown for
      19F, 20Ne, 31P and 32S target.)
 POL-TGT=0%;
 ALGN-TGT=0%;
 ACC=CYC;
 INST-ACC=2JPNKTO;
 POL-PRJ=0%;
 DET-PARTCL=ALPHA;
 COINC=NO;
 ANT-COINC=NO;
 DET-SYS=(SI'2',CSI'3');
 /* '2' To detect alpha. Energy calibration was done with the alpha
        particles produced in the known reactions such as
        27Al(p,alpha)24Mg, 16O(d,alpha)14N and 27Al(d,alpha)25Mg etc.
 /* '3' CSI(Tl) scintillation counter to monitor the beam current
        of incident deuterons */
 ERS-DET=1.2%'4';
 /* '4' Value at 20 MeV */
 /* Experimental Method:
    - Beam current integrated (Conventional current integrator with
      an accuracy better than 10%)
 /* 2006-10-05 : Altered, Is. Re-digitized */
 RCT=32S(D,ALPHA)30P;
 PHQ=ANGL-DSTRN;
 CHM=X'58';
 /* '58' Hydrogen sulfide */
 PHYS-FORM=GAS;
 THK-TGT=XMG/CM**2'59';
 /* '59' about 30 cmHg */
 INC-ENGY-LAB=14.5MEV;
 ANL=DIRECT-PROC'60';
 /* '60' Formulae proposed by el Nadi and Newns */
 /*===================================================================*/
 /* Descriptive Parameters                                            */
 /*===================================================================*/
 \\DATA,15;
 INC-ENGY-LAB=14.5MEV;
 SYS-ERR=<20%'61';
 /* '61' Maximum uncertainty of absolute values arise from beam
         current estimation */
 EXC-ENGY=1.97MEV;
 DELTA-THTL=+-3DEG;
 /*===================================================================*/
 /* Data Table                                                        */
 /*===================================================================*/
 \DATA;
 THTC DSIGMA/DOMEGA
 (DEG) (MB/SR)
 2.171E+01 3.915E-01
 2.594E+01 2.443E-01
 3.229E+01 1.895E-01
 4.235E+01 9.937E-02
 5.294E+01 7.312E-02
 6.353E+01 7.883E-02
 7.359E+01 7.312E-02
 8.418E+01 4.915E-02
 9.371E+01 4.801E-02
 1.043E+02 4.459E-02
 1.133E+02 3.774E-02
 1.234E+02 2.633E-02
 1.329E+02 2.747E-02
 1.429E+02 2.975E-02
 1.525E+02 1.834E-02
 1.620E+02 2.062E-02
 \END;
 /*===================================================================*/