/*===================================================================*/ /* NRDF D1849 Data No.17 */ /*===================================================================*/ /* Bibliography */ /*===================================================================*/ \\BIB,17; D#=D1849; TITLE=/Some evidence for neutron pick-up from the interior core through the (p,d) reaction/; ATH=(T.ISHIMATSU'1', S.HAYASHIBE'1', N.KAWAMURA'1', T.AWAYA'2', H.OHMURA'2', Y.NAKAJIMA'3', S.MITARAI'3'); INST-ATH=(2JPNTOH'1', 2JPNTOK'2', 2JPNKYU'3'); /* '1' Department of Physics */ /* '2' Department of Physics */ /* '3' Department of Physics */ REF=NP/A; VLP=185(1972)273; RCTS=(100MO(P,D)99MO, 94MO(P,D)93MO, 98MO(P,D)97MO); PHQS=ANGL-DSTRN; /*===================================================================*/ /* Experimental Conditions */ /*===================================================================*/ \\EXP,17; /* 2003-10-31 : Converted, Data converted from EXFOR O0586 */ PHQ=ANGL-DSTRN; CHM=ELM; PHYS-FORM=SLD'4'; /* '4' Metallic foils */ POL-TGT=0%; ALGN-TGT=0%; ACC=SYNCYC; INST-ACC=2JPNINS; INC-ENGY-LAB=52MEV; POL-PRJ=0%; DET-PARTCL=D; COINC=NO; ANT-COINC=NO; DET-SYS=(MAG'5',PROP-CNTR'6',PLST-SCT); /* '5' Broad-range magnetic spectrometer [K.Yagi et al., Nucl. Instr. 52(1967)29] */ /* '6' 200 proportional counters along the focal plane followed by a plastic scintillation counter with 6 phototubes */ /* Experimental Method: - Pulse-height discrimination (Aluminium foils placed in tront of proportional counters and a pulse-height discriminator for the outputs from the scintillation counters allowed the elimination of triton backgrounds from deuteron spectra.) RCT=98MO(P,D)97MO; ENR=97.0%; THK-TGT=3.12MG/CM**2; /* Analysis: - Integration of energy distribution (Integration of angular distributions over the levels in the residual nuclei in a range of excitation from 1.8 to 6.0 MeV) /*===================================================================*/ /* Descriptive Parameters */ /*===================================================================*/ \\DATA,17; INC-ENGY-LAB=52MEV; SYS-ERR=(10%'83',X%'84'); /* '83' Uncertainty in the solid angle of spectrometer */ /* '84' Uncertainties in the absolute cross sections are estimated to be less than +-20%. */ EMT=D; RSD=97MO; EXC-ENGY=1.8[6.0MEV; DELTA-EXC-ENGY=0.02MEV; DELTA-THTL=0.21DEG'85'; /* '85' Data-point reader uncertainty */ DELTA-DSIGMA/DOMEGA=1.6%'86'; /* '86' Data-point reader uncertainty */ /*===================================================================*/ /* Data Table */ /*===================================================================*/ \DATA; THTL DSIGMA/DOMEGA (DEG) (MB/SR) 5.14 20.1 7.57 20.4 10.26 19.4 12.61 15.95 15.27 12.94 17.5 11.64 20.03 10.57 22.42 9.72 25.06 7.63 27.8 5.05 31.02 3.58 34.6 3.14 37.17 3.19 40.3 2.86 43.55 2.22 46.76 1.588 49.27 1.319 52.88 1.251 57.04 1.023 \END; /*===================================================================*/ |