DARPE: Search Results
 /*===================================================================*/
 /* NRDF D0816 Data No.19                                             */
 /*===================================================================*/
 /* Bibliography                                                      */
 /*===================================================================*/
 \\BIB,19;
 D#=D816;
 TITLE=/ Tensor analyzing powers of the proton continuum spectra from
         deuteron breakup at 56 MeV /;
 ATH=(N.MATSUOKA'1', K.HATANAKA'1', H.SAKAI'1', T.SAITO'1', K.HOSONO'1',
      T.ITAHASHI'1', A.SHIMIZU'1', M.KONDO'1', H.SAKAGUCHI'2',
      F.OHTANI'2');
 INST-ATH=(2JPNRCN'1', 2JPNKTO'2');
      /* '2' Department of Physics */
 REF=NP/A;
 VLP=408(1983)99;
 RCTS=(58NI(D,P)X, 90ZR(D,P)X);
 PHQS=(DBL-DIFF-XSECTN, TNSR-ANALPW);
 /*===================================================================*/
 /* Experimental Conditions                                           */
 /*===================================================================*/
 \\EXP,19;
 /* 2007-08-24 : Converted, N.Otuka. Converted to EXFOR E0816 */
 CHM=ELM;
 PHYS-FORM=SLD;
 POL-TGT=0%;
 ALGN-TGT=0%;
 ACC=CYC'3';
 /* '3' Isochronous cyclotron, AVF cyclotron */
 INST-ACC=2JPNRCN;
 INC-ENGY-LAB-RANGE=56MEV;
 BEAM-INTNSTY=5[40NA;
 POL-PRJ=70[80%;
 DET-PARTCL=P;
 COINC=NO;
 ANT-COINC=NO;
 DET-SYS=(SI'4',GE'4',SI'5',NAI'5',EDE);
 /* '4' To detect protons */
 /* '5' To detect protons (6, 8, 10, 13 deg) */
 RCT=90ZR(D,P)X;
 PHQ=DBL-DIFF-XSECTN;
 ENR=97.7%;
 THK-TGT=3.95MG/CM**2;
 /* Data points lower than 20 MeV and higher than 45 MeV are mostly
    omitted because of high density of data points */
 /*===================================================================*/
 /* Descriptive Parameters                                            */
 /*===================================================================*/
 \\DATA,19;
 INC-ENGY-LAB=56MEV;
 STATIST-ERR=<2.5%'30';
 /* '30' Maximum statistical uncertainty (<2.5%) */
 THTL=6DEG;
 DELTA-DSIGMA/DOMEGA/DE=10%'31';
 /* '31' Uncertainty in absolute cross section, mainly due to
         uncertainty in target thickness */
 /*===================================================================*/
 /* Data Table                                                        */
 /*===================================================================*/
 \DATA;
 ENGY-EMT-LAB DSIGMA/DOMEGA/DE
 (MEV) (MB/SR/MEV)
 1.8475E+01 4.485E+01
 1.9477E+01 6.137E+01
 2.0571E+01 7.614E+01
 2.1575E+01 9.383E+01
 2.2463E+01 1.032E+02
 2.3552E+01 1.160E+02
 2.4546E+01 1.294E+02
 2.5451E+01 1.455E+02
 2.6636E+01 1.585E+02
 2.7341E+01 1.716E+02
 2.8527E+01 1.848E+02
 2.9510E+01 1.935E+02
 3.0482E+01 1.978E+02
 3.1537E+01 1.968E+02
 3.2769E+01 1.894E+02
 3.3615E+01 1.814E+02
 3.4438E+01 1.639E+02
 3.5462E+01 1.503E+02
 3.6378E+01 1.314E+02
 3.7391E+01 1.129E+02
 3.8501E+01 9.502E+01
 3.9329E+01 7.946E+01
 4.0442E+01 6.272E+01
 4.1373E+01 5.007E+01
 4.2495E+01 3.703E+01
 4.3532E+01 2.847E+01
 4.4479E+01 2.262E+01
 4.5336E+01 1.911E+01
 \END;
 /*===================================================================*/