DARPE: Search Results
 /*===================================================================*/
 /* NRDF D0815 Data No.2                                              */
 /*===================================================================*/
 /* Bibliography                                                      */
 /*===================================================================*/
 \\BIB,2;
 D#=D815;
 TITLE=/Analyzing power of the neutron continuum spectrum for the
        93Nb(p,nX) reaction at 65 MeV and a DWBA analysis/;
 PURPOSE=/To provide stringent test for various theories by simultaneous
          fitting of analyzing powers as well as cross sections for both
          neutron and proton spectra/;
 ATH=(H.SAKAI'1', K.HATANAKA'1', N.MATSUOKA'1', T.SAITO'1',
      A.SHIMIZU'1', T.MOTOBAYASHI'2', T.SHIBATA'1');
 INST-ATH=(2JPNRCN'1', 2JPNOSA'2');
      /* '2' Department of Physics */
 REF=PL/B;
 VLP=133(1983)375;
 RCTS=93NB(P,N)X;
 PHQS=(ENGY-SPEC'3', ANALPW, ANGL-DSTRN);
 /* '3' Double differential cross section */
 /*===================================================================*/
 /* Experimental Conditions                                           */
 /*===================================================================*/
 \\EXP,2;
 /* 2003-10-24 : Converted, Data converted to EXFOR E815 and EXFOR
    O0522 */
 ENR=X%;
 CHM=ELM;
 PHYS-FORM=SLD'4';
 /* '4' Metallic foil */
 THK-TGT=43.6MG/CM**2;
 BAC=SELF;
 POL-TGT=0%;
 ALGN-TGT=0%;
 ACC=CYC'5';
 /* '5'Isochronous cyclotron, RCNP AVF cyclotron */
 INST-ACC=2JPNRCN;
 INC-ENGY-LAB=65MEV;
 BEAM-INTNSTY=50NA'6';
 /* '6' maximum beam current */
 POL-PRJ=82.5+-2.5%'7';
 /* '7' The beam polarization was measured continuously with a
        12C-polarimeter placed down stream the main scattering chamber
 DET-PARTCL=N;
 COINC=NO;
 ANT-COINC=NO;
 DET-SYS=SCT'8';
 /* '8' two liquid scintillation counters (NE213) to detect
        neutrons */
 /* Experimental Method:
    - Time-of-flight (To determine outgoing neutron energy. The time
      resolution (FWHM) of the beam burst was typically 1.0-1.5 ns, and
      corresponding energy resolutions of the neutrons were about 4 and
      2 MeV for 50 and 30 MeV neutrons, respectively.)
 RCT=93NB(P,N)X;
 PHQ=ENGY-SPEC'13';
 /* '13' Double differential cross section */
 /*===================================================================*/
 /* Descriptive Parameters                                            */
 /*===================================================================*/
 \\DATA,2;
 INC-ENGY-LAB=65MEV;
 SYS-ERR=10%'14';
 /* '14' Estimated errors in the absolute magnitude of the cross
         section due to uncertainties in the neutron detection
         efficiency calculation */
 EMT=N;
 THTL=30DEG;
 DELTA-ENGY-EMT-LAB=0.27MEV'15';
 /* '15' Data-point reader uncertainty */
 DELTA-DSIGMA/DOMEGA/DE=+-3.0%'16';
 /* '16' Data-point reader uncertainty */
 /*===================================================================*/
 /* Data Table                                                        */
 /*===================================================================*/
 \DATA;
 ENGY-EMT-LAB DSIGMA/DOMEGA/DE
 (MEV) (MB/SR/MEV)
 16.23       2.33
  17.2       2.28
 17.83       1.93
 18.81       1.86
 20.52       2.12
  21.5       2.04
 22.29       1.96
 23.45       1.97
 24.42       1.97
  25.4        1.9
 26.95        1.9
 27.91       2.03
 29.07         2.
 30.44       1.92
  31.2       2.05
 32.36       2.06
 33.92       2.07
 35.08       2.04
 36.25       2.04
   38.       1.97
 39.17       1.98
 40.15        1.9
 41.14       1.75
 42.13       1.58
 43.33       1.43
  44.7       1.35
 46.27       1.27
 47.45       1.17
 48.83        1.1
 49.62       1.02
  51.2       0.92
 52.19      0.848
 53.18      0.782
 54.02      0.609
 55.41      0.539
 56.43      0.447
  57.9      0.289
 58.21       0.19
 59.48      0.125
 60.43     0.0639
 61.28     0.0233
 \END;
 /*===================================================================*/