 /* NRDF D0816 Data No.2                                              */
 /*===================================================================*/
 /* Bibliography                                                      */
 /*===================================================================*/
 \\BIB,2;
 D#=D816;
 TITLE=/ Tensor analyzing powers of the proton continuum spectra from
         deuteron breakup at 56 MeV /;
 ATH=(N.MATSUOKA'1', K.HATANAKA'1', H.SAKAI'1', T.SAITO'1', K.HOSONO'1',
      T.ITAHASHI'1', A.SHIMIZU'1', M.KONDO'1', H.SAKAGUCHI'2',
      F.OHTANI'2');
 INST-ATH=(2JPNRCN'1', 2JPNKTO'2');
      /* '2' Department of Physics */
 REF=NP/A;
 VLP=408(1983)99;
 RCTS=(58NI(D,P)X, 90ZR(D,P)X);
 PHQS=(DBL-DIFF-XSECTN, TNSR-ANALPW);
 /*===================================================================*/
 /* Experimental Conditions                                           */
 /*===================================================================*/
 \\EXP,2;
 /* 2007-08-24 : Converted, N.Otuka. Converted to EXFOR E0816 */
 CHM=ELM;
 PHYS-FORM=SLD;
 POL-TGT=0%;
 ALGN-TGT=0%;
 ACC=CYC'3';
 /* '3' Isochronous cyclotron, AVF cyclotron */
 INST-ACC=2JPNRCN;
 INC-ENGY-LAB-RANGE=56MEV;
 BEAM-INTNSTY=5[40NA;
 POL-PRJ=70[80%;
 DET-PARTCL=P;
 COINC=NO;
 ANT-COINC=NO;
 DET-SYS=(SI'4',GE'4',SI'5',NAI'5',EDE);
 /* '4' To detect protons */
 /* '5' To detect protons (6, 8, 10, 13 deg) */
 RCT=58NI(D,P)X;
 PHQ=DBL-DIFF-XSECTN;
 ENR=99.8%;
 THK-TGT=3.79MG/CM**2;
 /* Data points lower than 20 MeV and higher than 45 MeV are mostly
    omitted because of high density of data points */
 /*===================================================================*/
 /* Descriptive Parameters                                            */
 /*===================================================================*/
 \\DATA,2;
 INC-ENGY-LAB=56MEV;
 STATIST-ERR=<2.5%'8';
 /* '8' Maximum statistical uncertainty (<2.5%) */
 THTL=8DEG;
 DELTA-DSIGMA/DOMEGA/DE=10%'9';
 /* '9' Uncertainty in absolute cross section, mainly due to
        uncertainty in target thickness */
 /*===================================================================*/
 /* Data Table                                                        */
 /*===================================================================*/
 \DATA;
 ENGY-EMT-LAB DSIGMA/DOMEGA/DE
 (MEV) (MB/SR/MEV)
 1.8702E+01 2.910E+01
 1.9589E+01 3.628E+01
 2.0381E+01 4.444E+01
 2.1655E+01 5.182E+01
 2.2352E+01 6.096E+01
 2.3435E+01 6.931E+01
 2.4419E+01 7.669E+01
 2.5403E+01 8.407E+01
 2.6581E+01 9.203E+01
 2.7469E+01 9.981E+01
 2.8444E+01 1.027E+02
 2.9707E+01 1.041E+02
 3.0573E+01 1.013E+02
 3.1440E+01 9.880E+01
 3.2500E+01 9.588E+01
 3.3649E+01 8.887E+01
 3.4509E+01 8.283E+01
 3.5555E+01 7.310E+01
 3.6507E+01 6.492E+01
 3.7560E+01 5.811E+01
 3.8510E+01 4.916E+01
 3.9465E+01 4.176E+01
 4.0518E+01 3.553E+01
 4.1475E+01 2.988E+01
 4.2242E+01 2.579E+01
 4.3202E+01 2.092E+01
 4.4261E+01 1.761E+01
 4.5418E+01 1.468E+01
 \END;
 /*===================================================================*/