DARPE: Search Results
 /*===================================================================*/
 /* NRDF D1240 Data No.2                                              */
 /*===================================================================*/
 /* Bibliography                                                      */
 /*===================================================================*/
 \\BIB,2;
 D#=D1240;
 TITLE=/ Spallation of tantalum, tungsten and gold by 12-GeV protons
 ATH=(Y.ASANO'1', H.KARIYA'1', S.MORI'1', M.OKANO'1', M.SAKANO'1');
 INST-ATH=(2JPNTSU'1');
      /* '1' Institute of Applied Physics */
 REF=JPJ;
 VLP=57(1988)2995;
 RCTS=(TA(P,X)X, W(P,X)X, 197AU(P,X)X);
 PHQS=XSECTN;
 /*===================================================================*/
 /* Experimental Conditions                                           */
 /*===================================================================*/
 \\EXP,2;
 /* 2007-01-19 : Converted, N.Otuka. Converted to EXFOR E1240 */
 PHQ=XSECTN;
 /* Additional results shown but not compiled
    - Charge distribution (Shown in Fig.1,2 and 3 in reference)
    - Mass distribution (Shown in Fig.4, 5 and 6 in reference)
 ENR=NAT;
 CHM=ELM;
 PHYS-FORM=SLD;
 THK-TGT=[40MG/CM**2;
 POL-TGT=0%;
 ALGN-TGT=0%;
 ACC=SYN;
 INST-ACC=2JPNKEK;
 INC-ENGY-LAB-RANGE=12GEV;
 POL-PRJ=0%;
 DET-PARTCL=GAMMA'2';
 /* '2' Decay data not shown */
 COINC=NO;
 ANT-COINC=NO;
 DET-SYS=GE(LI)'3';
 /* '3' To measure gamma-ray spectra */
 /* Experimental Method:
    - Activation
    - Gamma ray spectrometry (Measured for 4 months (Au) or 7 weeks
      (Ta, W))
 RCT=TA(P,X)X'8';
 /* '8' See DATA section for atomic number (Z) and mass number (A)
        of products */
 /*===================================================================*/
 /* Descriptive Parameters                                            */
 /*===================================================================*/
 \\DATA,2;
 INC-ENGY-LAB=12GEV;
 TOT-ERR=X%'4';
 /* '4' Uncertainty in detection efficiencies of gamma-rays and
        statistical errors for photopeak yields (Uncertainty in
        branching ratios and beam calibration are not included.) */
 SYS-ERR=10%'5';
 /* '5' Uncertainty in beam calibration */
 /*===================================================================*/
 /* Data Table                                                        */
 /*===================================================================*/
 \DATA;
 Z A ISOMER SIGMA',9' DELTA-SIGMA''
 (NODIM) (NODIM) (NODIM) (MB) (MB)
 11. 24 X 9.00 +-0.61
 12. 28 X 2.23 +-0.16
 19. 43 X 7.03 +-0.78
 20. 47 X 0.84 +-0.08
 31. 72 X 1.78 +-0.19
 32. 69 X 3.02 +-0.48
 33. 71 X 1.54 +-0.31
 36. 79 X 3.67 +-0.79
 38. 83 X 3.36 +-0.30
 39. 87 0 6.05 +-0.41
 39. 87 1 5.44 +-0.70
 40. 89 X 5.44 +-0.36
 40. 97 X 0.26 +-0.05
 41. 90 X 4.68 +-0.34
 42. 93 1 1.47 +-0.14
 42. 99 X 3.44 +-0.43
 43. 94 X 1.93 +-0.24
 43. 95 X 3.51 +-0.50
 45. 100 X 3.97 +-0.39
 45. 105 X 2.85 +-0.24
 48. 115 X 1.20 +-0.13
 52. 131 1 5.29 +-1.00
 53. 131 X 2.66 +-0.36
 53. 135 X 1.37 +-0.21
 55. 129 X 11.3 +-2.8
 57. 132 X 12.6 +-3.9
 63. 145 X 12.1 +-0.8
 63. 157 X 13.9 +-5.6
 64. 147 X 16.7 +-1.2
 64. 149 X 8.14 +-1.30
 65. 151 X 9.29 +-0.72
 66. 157 X 16.5 +-1.7
 69. 165 X 18.9 +-1.8
 69. 172 X 5.19 +-0.33
 71. 169 X 21.9 +-1.7
 71. 170 X 20.7 +-1.9
 71. 171 X 24.8 +-1.9
 73. 176 X 14.7 +-1.5
 \END;
 /*===================================================================*/