DARPE: Search Results
 /*===================================================================*/
 /* NRDF D1241 Data No.2                                              */
 /*===================================================================*/
 /* Bibliography                                                      */
 /*===================================================================*/
 \\BIB,2;
 D#=D1241;
 TITLE=/ Spallation and fission yields in the interactions of
         tantalum, tungsten, and gold with 500-MeV protons /;
 ATH=(Y.ASANO'1', S.MORI'1', M.NOGUCHI'1', M.SAKANO'1', K.KATOH'2',
      K.KONDO'2');
 INST-ATH=(2JPNTSU'1', 2JPNKEK'2');
      /* '1' Institute of Applied Physics */
 REF=JPJ;
 VLP=54(1985)3734;
 RCTS=(TA(P,X)X, W(P,X)X, 197AU(P,X)X);
 PHQS=XSECTN;
 /*===================================================================*/
 /* Experimental Conditions                                           */
 /*===================================================================*/
 \\EXP,2;
 /* 2007-01-19 : Converted, N.Otuka. Converted to EXFOR E1241 */
 PHQ=XSECTN;
 /* Additional results shown but not compiled
    - Mass distribution (Shown in Fig.1 and 2 in reference)
 ENR=NAT;
 CHM=ELM;
 PHYS-FORM=SLD;
 THK-TGT=[40MG/CM**2;
 POL-TGT=0%;
 ALGN-TGT=0%;
 ACC=SYN;
 INST-ACC=2JPNKEK;
 INC-ENGY-LAB-RANGE=500MEV;
 POL-PRJ=0%;
 DET-PARTCL=GAMMA'3';
 /* '3' Decay data not given */
 COINC=NO;
 ANT-COINC=NO;
 DET-SYS=GE(LI)'4';
 /* '4' Used for gamma-ray spectroscopy */
 /* Experimental Method:
    - Stacked target irradiation (Total thickness of 1 g/cm2)
    - Activation (Irradiated for 3 min)
    - Gamma ray spectrometry (Measured for 7 months and also measured
      for 12 days 16 months, starting about 12 hours after irradiation)
 RCT=TA(P,X)X'8';
 /* '8' See DATA section for atomic number (Z) and mass number (A)
        of products */
 /*===================================================================*/
 /* Descriptive Parameters                                            */
 /*===================================================================*/
 \\DATA,2;
 INC-ENGY-LAB=500MEV;
 TOT-ERR=X%'5';
 /* '5' Uncertainty in detection efficiency of gamma rays and
        statistical uncertainties for photo-yields (Possible
        uncertainty in branching ratios of gamma rays and beam
        intensity calibration are not included.) */
 /*===================================================================*/
 /* Data Table                                                        */
 /*===================================================================*/
 \DATA;
 Z A SIGMA'9' DELTA-SIGMA
 (NODIM) (NODIM) (MB) (MB)
 27. 57 0.28 +-0.05
 37. 83 0.31 +-0.06
 38. 85 0.48 +-0.04
 39. 86 0.4 +-0.1
 39. 87 0.22 +-0.06
 53. 131 0.16 +-0.03
 53. 133 0.5 +-0.1
 58. 139 0.31 +-0.05
 58. 143 2.2 +-0.3
 60. 147 1.5 +-0.4
 63. 145 2.0 +-0.2
 63. 147 13 +-3
 64. 146 3.0 +-0.5
 64. 147 3.3 +-0.5
 64. 149 4.3 +-0.4
 65. 151 6 +-1
 65. 153 7.5 +-0.9
 65. 155 6 +-1
 66. 157 21 +-2
 67. 160 35 +-3
 67. 166 22 +-5
 69. 165 42 +-5
 69. 167 53 +-7
 70. 166 4.0 +-0.9
 70. 169 43 +-2
 71. 169 11 +-5
 71. 171 67 +-5
 71. 173 90 +-10
 72. 170 27 +-3
 72. 172 29 +-5
 72. 173 60 +-6
 72. 175 54 +-4
 73. 175 21 +-1
 73. 176 29 +-3
 \END;
 /*===================================================================*/