DARPE: Search Results
 /*===================================================================*/
 /* NRDF D1722 Data No.2                                              */
 /*===================================================================*/
 /* Bibliography                                                      */
 /*===================================================================*/
 \\BIB,2;
 D#=D1722;
 TITLE=/ Reaction mechanism and characteristics of T20 in d+3He
         backward elastic scattering at intermediate energies /;
 ATH=(M.TANIFUJI'1', S.ISHIKAWA'1', Y.ISERI'2', T.UESAKA'3',
      N.SAKAMOTO'3', Y.SATOU'3', K.ITOH'3', H.SAKAI'3,4', A.TAMII'4',
      T.OHNISHI'4', K.SEKIGUCHI'4', K.YAKO'4', S.SAKODA'4',
      H.OKAMURA'5', K.SUDA'5', T.WAKASA'6');
 INST-ATH=(2JPNHOS'1', 2JPNJPN'2', 2JPNIPC'3', 2JPNTOK'4', 2JPNSUU'5',
           2JPNRCN'6');
      /* '1' Department of Physics */
      /* '2' Department of Physics, Chiba-Keizai College, Chiba */
      /* '4' Department of Physics */
      /* '5' Department of Physics */
 REF=PR/C;
 VLP=61(2000)024602;
 RCTS=D(3HE,3HE)D;
 PHQS=(ANGL-DSTRN, TNSR-ANALPW'7');
 /* '7' T(20) */
 /*===================================================================*/
 /* Experimental Conditions                                           */
 /*===================================================================*/
 \\EXP,2;
 /* 2002-09-05 : Converted, Data converted to EXFOR E1722 */
 /* 2004-11-25 : Altered, INSTITUTE, REFERENCE and heading of
    systematic error corrected */
 RTY=(ELA-SCATT,POL-RCT);
 ENR=X%;
 CHM=ELM;
 PHYS-FORM=GAS;
 THK-TGT=XMG/CM**2'8';
 /* '8' The size of target was 13mm(20mm) wide, 15mm(20mm)high, and
        20mm(10mm)thick in the case of 270MeV(140,200MeV) measurement.
        The gas pressure is approximately 1 atm which was measured with
        Baratron gauge. */
 POL-TGT=0%;
 ALGN-TGT=0%;
 ACC=CYC;
 INST-ACC=2JPNIPC;
 INC-ENGY-LAB=(140MEV, 200MEV, 270MEV);
 POL-PRJ=60[80%;
 ION-SOURCE=/ Polarized ion source (High-Intensity polarized ion source
              [H.Okamura et al., in polarized ion source and polarized
              gas targets, edited by L.W.Anderson and Willy Haeberli,
              AIP Conf.Proc.No.293(AIP, New York, 1994), P.84]) /;
 DET-PARTCL=3HE;
 COINC=NO;
 ANT-COINC=NO;
 DET-SYS=(MAG'9',MWDC,SCT'10');
 /* '9' SMART [T.Ichihara et al., Nucl.Phys.A569(1994)287c]. */
 /* '10' Plastic scintillator */
 MONTR-RCT=/ , The beam polarization was measured with a polarimeter
             based on the d+p elastic scattering after acceleration to
             140, 200, and 270MeV. /;
 ANL=PWIA;
 RCT=D(3HE,3HE)D;
 PHQ=TNSR-ANALPW'13';
 /* '13' T(20) */
 /*===================================================================*/
 /* Descriptive Parameters                                            */
 /*===================================================================*/
 \\DATA,2;
 EMT=3HE;
 THTL=0[1.4DEG;
 DELTA-T20=2%'14';
 /* '14' Unncertainty mainly due to beam polarization */
 /*===================================================================*/
 /* Data Table                                                        */
 /*===================================================================*/
 \DATA;
 INC-ENGY-LAB T20 DELTA-T20'15'
 (MEV) (NODIM) (NODIM)
 140 0.07 +-0.02
 200 0.15 +-0.01
 270 0.17 +-0.03
 \END;
 /*===================================================================*/