DARPE: Search Results
 /*===================================================================*/
 /* NRDF D1882 Data No.2                                              */
 /*===================================================================*/
 /* Bibliography                                                      */
 /*===================================================================*/
 \\BIB,2;
 D#=D1882;
 TITLE=/ Spallation of niobium by 12 GeV protons /;
 ATH=(T.TOMINAKA'1', S.BAN'1', H.IKEDA'1', K.KATOH'1', K.KONDO'1',
      M.TAKASAKI'1', A.YAMAMOTO'1', H.HIRABAYASHI'1', Y.NARAHARA'2');
 INST-ATH=(2JPNLEP'1', 2JPNTSU'2');
      /* '2' Institute of Physics */
 REF=NP/A;
 VLP=414(1984)385;
 RCTS=93NB(P,X)X;
 PHQS=(XSECTN'3', XSECTN'4', XSECTN);
 /* '3' Independent cross section */
 /* '4' Cumulative cross section */
 /*===================================================================*/
 /* Experimental Conditions                                           */
 /*===================================================================*/
 \\EXP,2;
 /* 2004-02-28 : Compiled, Kc + On */
 /* Related references 
    - C.M.Lederer et al., LEDERER-7, (1978).
    Reference from which data were used (Decay data)
    - J.B.Cumming et al., NIM, 180(1981)37.
 CHM=ELM;
 PHYS-FORM=SLD;
 THK-TGT=XMG/CM**2'5';
 /* '5' 50 micro-meter thick for each stack */
 POL-TGT=0%;
 ALGN-TGT=0%;
 ACC=SYN;
 INST-ACC=2JPNKEK;
 INC-ENGY-LAB=12GEV;
 BEAM-INTNSTY=XUA'6';
 /* '6' about 1.2e11 protons/pulse */
 POL-PRJ=0%;
 COINC=NO;
 ANT-COINC=NO;
 DET-SYS=GE(LI)'7';
 /* '7' Resolution is 2.0 keV at 1332 keV. Efficiency is 10 %
        relative to 7.6 cm x 7.6 cm NaI. */
 /* Experimental Method:
    - Irradiation with external beam (Exposed for 3 min)
    - Gamma ray spectrometry (Measured commencing at 75 min after the
      irradiation and continuing intermittently for 200 days)
 RCT=93NB(P,X)X;
 PHQ=XSECTN'13';
 /* '13' Cumulative cross section */
 DET-PARTCL=GAMMA'14';
 /* '14' . Gamma energies and half-lives are not given except the
         half-life of 84Y (39 min). */
 MONTR-RCT=/ 27AL(P,N,3*P)24NA /;
 /*===================================================================*/
 /* Descriptive Parameters                                            */
 /*===================================================================*/
 \\DATA,2;
 INC-ENGY-LAB=12GEV;
 SYS-ERR=[10%'15';
 /* '15' Uncertainty due to the secondary emission chamber
         calibration */
 DATA1=28GEV'16';
 /* '16' Incident energy for adopted monitor cross section which
         is independent between 10 and 28 GeV [J.B. Cumming, Ann. Rev.
         Nucl. Sci. 13(1963)261]. */
 DATA2=7.92MB;
 /*===================================================================*/
 /* Data Table                                                        */
 /*===================================================================*/
 \DATA;
 Z A ISOMER XSECTN DELTA-XSECTN'17' FLAG'18'
 (NODIM) (NODIM) (NODIM) (MB) (MB) (NODIM)
 11 24 X 3.64 +-0.23 X
 20 47 X 1.02 +-0.12 X
 25 56 X 1.18 +-0.27 X
 30 65 X 8.08 +-0.89 X
 31 67 X 8.40 +-0.53 X
 32 69 X 8.57 +-0.74 X
 33 71 X 6.81 +-1.94 X
 34 73 X 4.82 +-0.43 1
 35 75 X 4.64 +-0.60 X
 36 76 X 1.55 +-0.62 X
 36 77 X 2.24 +-0.17 X
 36 79 X 11.9 +-0.91 X
 37 81 X 16.4 +-2.5 1
 38 82 X 6.63 +-0.88 X
 38 83 X 11.8 +-1.3 X
 39 84 1 2.23 +-0.29 1
 39 87 1 22.8 +-4.0 X
 40 86 X 3.56 +-0.24 X
 40 88 X 13.6 +-3.8 X
 40 89 X 31.8 +-2.3 X
 \END;
 /*===================================================================*/