DARPE: Search Results
 /*===================================================================*/
 /* NRDF D1927 Data No.2                                              */
 /*===================================================================*/
 /* Bibliography                                                      */
 /*===================================================================*/
 \\BIB,2;
 D#=D1927;
 TITLE=/ Experimental studies on excitation functions of the
         proton-induced activation reactions on silver /;
 PURPOSE=/ To present the cross-section measurement for Ag-p reaction
           in the enegy range 11-80 MeV. /;
 ATH=(M.S.UDDIN'1', M.HAGIWARA'1', M.BABA'1', F.TARKANYI'2',
      F.DITROI'2');
 INST-ATH=(2JPNTOH'1', 3HUNDEB'2');
      /* '1' Cyclotron and Radioisotope Center */
 REF=ARI;
 VLP=62(2005)533;
 /* Secondary reference 
    - UDDIN, Private communication(2005)
 RCTS=(AG(P,X)103PD, AG(P,X)101PD, AG(P,X)100PD, AG(P,X)99RH,
       AG(P,X)100RH, AG(P,X)101RH, AG(P,X)102RH, AG(P,X)105RH,
       AG(P,X)97RU, AG(P,X)105AG, AG(P,X)106AG);
 PHQS=XSECTN;
 /*===================================================================*/
 /* Experimental Conditions                                           */
 /*===================================================================*/
 \\EXP,2;
 /* 2005-06-29 : Compiled, Tk + On. */
 PHQ=XSECTN;
 ENR=NAT;
 CHM=ELM;
 PHYS-FORM=SLD;
 THK-TGT=XMG/CM**2'3';
 /* '3' 50 and 300 micrometer thick */
 POL-TGT=0%;
 ALGN-TGT=0%;
 ACC=CYC'4';
 /* '4' Isochronous cyclotron, AVF cyclotron */
 INST-ACC=2JPNTOH'5';
 /* '5' Cyclotron and Radioisotope Center */
 POL-PRJ=0%;
 COINC=NO;
 ANT-COINC=NO;
 DET-SYS=HPGE'6';
 /* '6' To measure activities in silver target and monitors */
 /* Experimental Method:
    - Activation ( Irradiated separately with 50, 70 and 80 MeV
      proton beam)
    - Stacked target irradiation (Three stacks containing high-purity
      thin silver foils)
    - Gamma ray spectrometry (Measurement started 1 day after the end
      of bombardment)
 /* Related references 
    - M.Fassbender et al., RCA, 87(1999)87.
    Reference with which data agree (Consistent with the present data)
    - Y.N.Shubin et al., IAEA-NDS-, 204(1998).
    Reference with which data disagree (Overestimates the present data)
 RCT=AG(P,X)101PD;
 DET-PARTCL=GAMMA'14';
 /* '14' Delayed gamma from 101Pd */
 /*===================================================================*/
 /* Descriptive Parameters                                            */
 /*===================================================================*/
 \\DATA,2;
 TOT-ERR=X%'7';
 /* '7' Uncertainty estimated from the uncertaintiies of the flux,
        counting area and detector efficiency */
 SYS-ERR=(5%'8',3%'9');
 /* '8' Upper limit of uncertainty in monitor flux (2.54-5%) */
 /* '9' Upper limit of uncertainty in efficiency calibration of
        gamma-ray (1-3%) */
 STATIST-ERR=22%'10';
 /* '10' Upper limit of statistical uncertainty (0.8-22%) */
 ENGY-GAMMA=(269.67KEV'15',296.29KEV'16',590.44KEV'17');
 INTNSTY-GAMMA=(0.0643'15',0.192'16',0.121'17');
 HALF-LIFE=(8.47HOUR'15',8.47HOUR'16',8.47HOUR'17');
 /* '15' Delayed gamma from 101Pd */
 /* '16' Delayed gamma from 101Pd */
 /* '17' Delayed gamma from 101Pd */
 /*===================================================================*/
 /* Data Table                                                        */
 /*===================================================================*/
 \DATA;
 INC-ENGY-LAB XSECTN'18' DELTA-XSECTN'18'
 (MEV) (MB) (MB)
 38.57 2.83 +-0.51
 42.14 9.49 +-1.03
 42.70 12.83 +-1.30
 46.30 22.3 +-1.49
 47.26 24.46 +-1.92
 48.15 25.68 +-2.67
 50.91 28.70 +-2.09
 53.12 29.93 +-2.67
 55.03 26.79 +-2.06
 57.78 20.98 +-2.29
 58.23 20.38 +-1.74
 61.89 17.70 +-1.68
 63.35 15.71 +-1.44
 64.98 17.30 +-1.69
 68.61 18.37 +-1.45
 73.40 23.22 +-1.25
 78.12 28.62 +-1.18
 \END;
 /*===================================================================*/