DARPE: Search Results
 /*===================================================================*/
 /* NRDF D1996 Data No.2                                              */
 /*===================================================================*/
 /* Bibliography                                                      */
 /*===================================================================*/
 \\BIB,2;
 D#=D1996;
 TITLE=/ Alpha beam monitoring via natCu + alpha processes in the
         energy range from 40 to 60 MeV /;
 ATH=(F.SZELECSENYI'1', K.SUZUKI'2', Z.KOVACS'1', M.TAKEI'2',
      K.OKADA'2');
 INST-ATH=(3HUNDEB'1', 2JPNIRS'2');
      /* '1' Cyclotron Department */
      /* '2' Division of Advanced Technology for Medical Imaging */
 REF=NIM/B;
 VLP=184(2001)589;
 RCTS=(CU(ALPHA,X)61CU, CU(ALPHA,X)66GA, CU(ALPHA,X)67GA);
 PHQS=XSECTN;
 /*===================================================================*/
 /* Experimental Conditions                                           */
 /*===================================================================*/
 \\EXP,2;
 /* 2006-09-06 : Compiled, Tk + On */
 PHQ=XSECTN;
 CHM=ELM;
 PHYS-FORM=SLD;
 POL-TGT=0%;
 ALGN-TGT=0%;
 ACC=CYC'3';
 /* '3' Isochronous cyclotron, AVF cyclotron */
 INST-ACC=2JPNIRS;
 BEAM-INTNSTY=(94NA,96NA,183NA);
 POL-PRJ=0%;
 COINC=NO;
 ANT-COINC=NO;
 DET-SYS=HPGE'4';
 /* '4' To determine activity of samples */
 /* Experimental Method:
    - Activation (Irradiated for 10, 20 and 30 min (3 runs))
    - Stacked target irradiation (Stacks made up of natCu and natCo)
    - Beam current integrated (Via electric charge collection in
      Faraday cage)
 /* Related references 
    - common, A0465007, J(Pram)31.
    . See also EXFOR commo.n.
    - Compared with present result, A0510376, B(Levk).
    . See also EXFOR 109..
    - Compared with present result, A0353003, J(Radi)39.
    - Compared with present result, D4085003, J(Nucl)168.
    . See also EXFOR 61..
 RCT=CU(ALPHA,X)66GA;
 INC-ENGY-LAB=15[59MEV;
 DET-PARTCL=GAMMA'14';
 /* '14' Delayed gamma from 66Ga */
 /*===================================================================*/
 /* Descriptive Parameters                                            */
 /*===================================================================*/
 \\DATA,2;
 TOT-ERR=12%;
 SYS-ERR=(8%'5',5%'6',3%'7');
 /* '5' Uncertainty in flux measurement */
 /* '6' Uncertainty in detector efficiency */
 /* '7' Uncertainty in nuclear data */
 STATIST-ERR=<1%'8';
 /* '8' Maximum uncertainty in counting statistics */
 ENGY-GAMMA=(833.58KEV'15',1039.35KEV'16');
 INTNSTY-GAMMA=(0.0603'15',0.3792'16');
 HALF-LIFE=(9.49HOUR'16',9.49HOUR'15');
 /* '15' Delayed gamma from 66Ga via NONe */
 /* '16' Delayed gamma from 66Ga via NONe */
 /*===================================================================*/
 /* Data Table                                                        */
 /*===================================================================*/
 \DATA;
 INC-ENGY-LAB DELTA-INC-ENGY-LAB'17' SIGMA DELTA-SIGMA
 (MEV) (MEV) (MB) (MB)
 15.9 +-1.9 466.7 +-51.0
 19.2 +-1.7 479.4 +-52.8
 20.8 +-2.6 146.9 +-16.2
 22.3 +-1.6 271.7 +-29.9
 25.1 +-1.5 140.0 +-15.6
 25.7 +-2.3 70.3 +-7.8
 27.7 +-1.3 57.5 +-6.4
 28.9 +-2.2 38.0 +-4.2
 30.0 +-1.2 32.3 +-3.5
 32.1 +-2.0 49.3 +-5.5
 32.3 +-1.1 39.3 +-4.3
 34.2 +-1.9 82.3 +-9.1
 34.4 +-1.0 64.1 +-7.1
 35.3 +-1.8 98.8 +-10.8
 36.5 +-0.9 97.5 +-10.8
 37.9 +-1.7 133.7 +-14.7
 38.3 +-1.7 128.8 +-14.3
 40.3 +-0.7 153.2 +-17.0
 41.1 +-1.5 152.9 +-16.9
 41.2 +-1.5 157.5 +-17.3
 43.7 +-1.4 158.1 +-17.3
 44.5 +-1.4 146.9 +-16.2
 46.8 +-1.3 131.8 +-14.5
 47.6 +-1.2 126.4 +-13.9
 49.9 +-1.1 92.4 +-10.2
 50.6 +-1.1 91.2 +-10.1
 52.7 +-1.0 75.5 +-8.4
 53.3 +-0.9 71.7 +-7.9
 55.4 +-0.8 85.0 +-10.1
 56.0 +-0.8 54.9 +-6.1
 58.1 +-0.7 45.3 +-5.0
 \END;
 /*===================================================================*/