/*===================================================================*/ /* NRDF D1996 Data No.2 */ /*===================================================================*/ /* Bibliography */ /*===================================================================*/ \\BIB,2; D#=D1996; TITLE=/ Alpha beam monitoring via natCu + alpha processes in the energy range from 40 to 60 MeV /; ATH=(F.SZELECSENYI'1', K.SUZUKI'2', Z.KOVACS'1', M.TAKEI'2', K.OKADA'2'); INST-ATH=(3HUNDEB'1', 2JPNIRS'2'); /* '1' Cyclotron Department */ /* '2' Division of Advanced Technology for Medical Imaging */ REF=NIM/B; VLP=184(2001)589; RCTS=(CU(ALPHA,X)61CU, CU(ALPHA,X)66GA, CU(ALPHA,X)67GA); PHQS=XSECTN; /*===================================================================*/ /* Experimental Conditions */ /*===================================================================*/ \\EXP,2; /* 2006-09-06 : Compiled, Tk + On */ PHQ=XSECTN; CHM=ELM; PHYS-FORM=SLD; POL-TGT=0%; ALGN-TGT=0%; ACC=CYC'3'; /* '3' Isochronous cyclotron, AVF cyclotron */ INST-ACC=2JPNIRS; BEAM-INTNSTY=(94NA,96NA,183NA); POL-PRJ=0%; COINC=NO; ANT-COINC=NO; DET-SYS=HPGE'4'; /* '4' To determine activity of samples */ /* Experimental Method: - Activation (Irradiated for 10, 20 and 30 min (3 runs)) - Stacked target irradiation (Stacks made up of natCu and natCo) - Beam current integrated (Via electric charge collection in Faraday cage) /* Related references - common, A0465007, J(Pram)31. . See also EXFOR commo.n. - Compared with present result, A0510376, B(Levk). . See also EXFOR 109.. - Compared with present result, A0353003, J(Radi)39. - Compared with present result, D4085003, J(Nucl)168. . See also EXFOR 61.. RCT=CU(ALPHA,X)66GA; INC-ENGY-LAB=15[59MEV; DET-PARTCL=GAMMA'14'; /* '14' Delayed gamma from 66Ga */ /*===================================================================*/ /* Descriptive Parameters */ /*===================================================================*/ \\DATA,2; TOT-ERR=12%; SYS-ERR=(8%'5',5%'6',3%'7'); /* '5' Uncertainty in flux measurement */ /* '6' Uncertainty in detector efficiency */ /* '7' Uncertainty in nuclear data */ STATIST-ERR=<1%'8'; /* '8' Maximum uncertainty in counting statistics */ ENGY-GAMMA=(833.58KEV'15',1039.35KEV'16'); INTNSTY-GAMMA=(0.0603'15',0.3792'16'); HALF-LIFE=(9.49HOUR'16',9.49HOUR'15'); /* '15' Delayed gamma from 66Ga via NONe */ /* '16' Delayed gamma from 66Ga via NONe */ /*===================================================================*/ /* Data Table */ /*===================================================================*/ \DATA; INC-ENGY-LAB DELTA-INC-ENGY-LAB'17' SIGMA DELTA-SIGMA (MEV) (MEV) (MB) (MB) 15.9 +-1.9 466.7 +-51.0 19.2 +-1.7 479.4 +-52.8 20.8 +-2.6 146.9 +-16.2 22.3 +-1.6 271.7 +-29.9 25.1 +-1.5 140.0 +-15.6 25.7 +-2.3 70.3 +-7.8 27.7 +-1.3 57.5 +-6.4 28.9 +-2.2 38.0 +-4.2 30.0 +-1.2 32.3 +-3.5 32.1 +-2.0 49.3 +-5.5 32.3 +-1.1 39.3 +-4.3 34.2 +-1.9 82.3 +-9.1 34.4 +-1.0 64.1 +-7.1 35.3 +-1.8 98.8 +-10.8 36.5 +-0.9 97.5 +-10.8 37.9 +-1.7 133.7 +-14.7 38.3 +-1.7 128.8 +-14.3 40.3 +-0.7 153.2 +-17.0 41.1 +-1.5 152.9 +-16.9 41.2 +-1.5 157.5 +-17.3 43.7 +-1.4 158.1 +-17.3 44.5 +-1.4 146.9 +-16.2 46.8 +-1.3 131.8 +-14.5 47.6 +-1.2 126.4 +-13.9 49.9 +-1.1 92.4 +-10.2 50.6 +-1.1 91.2 +-10.1 52.7 +-1.0 75.5 +-8.4 53.3 +-0.9 71.7 +-7.9 55.4 +-0.8 85.0 +-10.1 56.0 +-0.8 54.9 +-6.1 58.1 +-0.7 45.3 +-5.0 \END; /*===================================================================*/ |