DARPE: Search Results
 /*===================================================================*/
 /* NRDF D0816 Data No.20                                             */
 /*===================================================================*/
 /* Bibliography                                                      */
 /*===================================================================*/
 \\BIB,20;
 D#=D816;
 TITLE=/ Tensor analyzing powers of the proton continuum spectra from
         deuteron breakup at 56 MeV /;
 ATH=(N.MATSUOKA'1', K.HATANAKA'1', H.SAKAI'1', T.SAITO'1', K.HOSONO'1',
      T.ITAHASHI'1', A.SHIMIZU'1', M.KONDO'1', H.SAKAGUCHI'2',
      F.OHTANI'2');
 INST-ATH=(2JPNRCN'1', 2JPNKTO'2');
      /* '2' Department of Physics */
 REF=NP/A;
 VLP=408(1983)99;
 RCTS=(58NI(D,P)X, 90ZR(D,P)X);
 PHQS=(DBL-DIFF-XSECTN, TNSR-ANALPW);
 /*===================================================================*/
 /* Experimental Conditions                                           */
 /*===================================================================*/
 \\EXP,20;
 /* 2007-08-24 : Converted, N.Otuka. Converted to EXFOR E0816 */
 CHM=ELM;
 PHYS-FORM=SLD;
 POL-TGT=0%;
 ALGN-TGT=0%;
 ACC=CYC'3';
 /* '3' Isochronous cyclotron, AVF cyclotron */
 INST-ACC=2JPNRCN;
 INC-ENGY-LAB-RANGE=56MEV;
 BEAM-INTNSTY=5[40NA;
 POL-PRJ=70[80%;
 DET-PARTCL=P;
 COINC=NO;
 ANT-COINC=NO;
 DET-SYS=(SI'4',GE'4',SI'5',NAI'5',EDE);
 /* '4' To detect protons */
 /* '5' To detect protons (6, 8, 10, 13 deg) */
 RCT=90ZR(D,P)X;
 PHQ=DBL-DIFF-XSECTN;
 ENR=97.7%;
 THK-TGT=3.95MG/CM**2;
 /* Data points lower than 20 MeV and higher than 45 MeV are mostly
    omitted because of high density of data points */
 /*===================================================================*/
 /* Descriptive Parameters                                            */
 /*===================================================================*/
 \\DATA,20;
 INC-ENGY-LAB=56MEV;
 STATIST-ERR=<2.5%'32';
 /* '32' Maximum statistical uncertainty (<2.5%) */
 THTL=8DEG;
 DELTA-DSIGMA/DOMEGA/DE=10%'33';
 /* '33' Uncertainty in absolute cross section, mainly due to
         uncertainty in target thickness */
 /*===================================================================*/
 /* Data Table                                                        */
 /*===================================================================*/
 \DATA;
 ENGY-EMT-LAB DSIGMA/DOMEGA/DE
 (MEV) (MB/SR/MEV)
 1.8429E+01 2.580E+01
 1.9606E+01 3.512E+01
 2.0487E+01 4.153E+01
 2.1374E+01 5.066E+01
 2.2554E+01 6.115E+01
 2.3442E+01 7.067E+01
 2.4529E+01 8.272E+01
 2.5509E+01 9.029E+01
 2.6686E+01 1.000E+02
 2.7478E+01 1.091E+02
 2.8460E+01 1.177E+02
 2.9428E+01 1.202E+02
 3.0488E+01 1.212E+02
 3.1545E+01 1.211E+02
 3.2403E+01 1.180E+02
 3.3442E+01 1.100E+02
 3.4383E+01 1.017E+02
 3.5509E+01 9.038E+01
 3.6436E+01 7.618E+01
 3.7471E+01 6.684E+01
 3.8406E+01 5.574E+01
 3.9440E+01 4.620E+01
 4.0381E+01 3.764E+01
 4.1520E+01 3.140E+01
 4.2464E+01 2.439E+01
 4.3417E+01 2.088E+01
 4.4562E+01 1.698E+01
 4.5426E+01 1.658E+01
 \END;
 /*===================================================================*/