DARPE: Search Results
 /*===================================================================*/
 /* NRDF D0816 Data No.23                                             */
 /*===================================================================*/
 /* Bibliography                                                      */
 /*===================================================================*/
 \\BIB,23;
 D#=D816;
 TITLE=/ Tensor analyzing powers of the proton continuum spectra from
         deuteron breakup at 56 MeV /;
 ATH=(N.MATSUOKA'1', K.HATANAKA'1', H.SAKAI'1', T.SAITO'1', K.HOSONO'1',
      T.ITAHASHI'1', A.SHIMIZU'1', M.KONDO'1', H.SAKAGUCHI'2',
      F.OHTANI'2');
 INST-ATH=(2JPNRCN'1', 2JPNKTO'2');
      /* '2' Department of Physics */
 REF=NP/A;
 VLP=408(1983)99;
 RCTS=(58NI(D,P)X, 90ZR(D,P)X);
 PHQS=(DBL-DIFF-XSECTN, TNSR-ANALPW);
 /*===================================================================*/
 /* Experimental Conditions                                           */
 /*===================================================================*/
 \\EXP,23;
 /* 2007-08-24 : Converted, N.Otuka. Converted to EXFOR E0816 */
 CHM=ELM;
 PHYS-FORM=SLD;
 POL-TGT=0%;
 ALGN-TGT=0%;
 ACC=CYC'3';
 /* '3' Isochronous cyclotron, AVF cyclotron */
 INST-ACC=2JPNRCN;
 INC-ENGY-LAB-RANGE=56MEV;
 BEAM-INTNSTY=5[40NA;
 POL-PRJ=70[80%;
 DET-PARTCL=P;
 COINC=NO;
 ANT-COINC=NO;
 DET-SYS=(SI'4',GE'4',SI'5',NAI'5',EDE);
 /* '4' To detect protons */
 /* '5' To detect protons (6, 8, 10, 13 deg) */
 RCT=90ZR(D,P)X;
 PHQ=DBL-DIFF-XSECTN;
 ENR=97.7%;
 THK-TGT=3.95MG/CM**2;
 /* Data points lower than 20 MeV and higher than 45 MeV are mostly
    omitted because of high density of data points */
 /*===================================================================*/
 /* Descriptive Parameters                                            */
 /*===================================================================*/
 \\DATA,23;
 INC-ENGY-LAB=56MEV;
 STATIST-ERR=<2.5%'38';
 /* '38' Maximum statistical uncertainty (<2.5%) */
 THTL=20DEG;
 DELTA-DSIGMA/DOMEGA/DE=10%'39';
 /* '39' Uncertainty in absolute cross section, mainly due to
         uncertainty in target thickness */
 /*===================================================================*/
 /* Data Table                                                        */
 /*===================================================================*/
 \DATA;
 ENGY-EMT-LAB DSIGMA/DOMEGA/DE
 (MEV) (MB/SR/MEV)
 1.8670E+01 6.349E+00
 1.9730E+01 7.311E+00
 2.0694E+01 8.273E+00
 2.1563E+01 9.626E+00
 2.2431E+01 1.059E+01
 2.3395E+01 1.155E+01
 2.4359E+01 1.290E+01
 2.5517E+01 1.464E+01
 2.6385E+01 1.541E+01
 2.7540E+01 1.618E+01
 2.8503E+01 1.656E+01
 2.9465E+01 1.694E+01
 3.0330E+01 1.654E+01
 3.1290E+01 1.614E+01
 3.2250E+01 1.555E+01
 3.3307E+01 1.495E+01
 3.4361E+01 1.358E+01
 3.5225E+01 1.299E+01
 3.6183E+01 1.162E+01
 3.7335E+01 1.083E+01
 3.8292E+01 9.071E+00
 3.9252E+01 8.283E+00
 4.0211E+01 7.302E+00
 4.1268E+01 6.708E+00
 4.2228E+01 6.115E+00
 4.3187E+01 5.327E+00
 4.4340E+01 4.733E+00
 4.5203E+01 3.946E+00
 \END;
 /*===================================================================*/