 TITLE=/ Tensor analyzing powers of the proton continuum spectra from
         deuteron breakup at 56 MeV /;
 ATH=(N.MATSUOKA'1', K.HATANAKA'1', H.SAKAI'1', T.SAITO'1', K.HOSONO'1',
      T.ITAHASHI'1', A.SHIMIZU'1', M.KONDO'1', H.SAKAGUCHI'2',
      F.OHTANI'2');
 INST-ATH=(2JPNRCN'1', 2JPNKTO'2');
      /* '2' Department of Physics */
 REF=NP/A;
 VLP=408(1983)99;
 RCTS=(58NI(D,P)X, 90ZR(D,P)X);
 PHQS=(DBL-DIFF-XSECTN, TNSR-ANALPW);
 /*===================================================================*/
 /* Experimental Conditions                                           */
 /*===================================================================*/
 \\EXP,24;
 /* 2007-08-24 : Converted, N.Otuka. Converted to EXFOR E0816 */
 CHM=ELM;
 PHYS-FORM=SLD;
 POL-TGT=0%;
 ALGN-TGT=0%;
 ACC=CYC'3';
 /* '3' Isochronous cyclotron, AVF cyclotron */
 INST-ACC=2JPNRCN;
 INC-ENGY-LAB-RANGE=56MEV;
 BEAM-INTNSTY=5[40NA;
 POL-PRJ=70[80%;
 DET-PARTCL=P;
 COINC=NO;
 ANT-COINC=NO;
 DET-SYS=(SI'4',GE'4',SI'5',NAI'5',EDE);
 /* '4' To detect protons */
 /* '5' To detect protons (6, 8, 10, 13 deg) */
 RCT=90ZR(D,P)X;
 PHQ=DBL-DIFF-XSECTN;
 ENR=97.7%;
 THK-TGT=3.95MG/CM**2;
 /* Data points lower than 20 MeV and higher than 45 MeV are mostly
    omitted because of high density of data points */
 /*===================================================================*/
 /* Descriptive Parameters                                            */
 /*===================================================================*/
 \\DATA,24;
 INC-ENGY-LAB=56MEV;
 STATIST-ERR=<2.5%'40';
 /* '40' Maximum statistical uncertainty (<2.5%) */
 THTL=30DEG;
 DELTA-DSIGMA/DOMEGA/DE=10%'41';
 /* '41' Uncertainty in absolute cross section, mainly due to
         uncertainty in target thickness */
 /*===================================================================*/
 /* Data Table                                                        */
 /*===================================================================*/
 \DATA;
 ENGY-EMT-LAB DSIGMA/DOMEGA/DE
 (MEV) (MB/SR/MEV)
 1.8664E+01 3.821E+00
 1.9723E+01 4.199E+00
 2.0685E+01 4.579E+00
 2.1551E+01 4.764E+00
 2.2610E+01 5.143E+00
 2.3476E+01 5.329E+00
 2.4342E+01 5.709E+00
 2.5496E+01 5.698E+00
 2.6458E+01 5.883E+00
 2.7420E+01 6.067E+00
 2.8381E+01 5.863E+00
 2.9342E+01 5.659E+00
 3.0399E+01 5.260E+00
 3.1263E+01 4.862E+00
 3.2320E+01 4.463E+00
 3.3281E+01 4.453E+00
 3.4338E+01 4.249E+00
 3.5395E+01 3.655E+00
 3.6452E+01 3.644E+00
 3.7316E+01 3.052E+00
 3.8181E+01 2.849E+00
 3.9141E+01 2.062E+00
 4.0390E+01 1.855E+00
 4.1256E+01 1.846E+00
 4.2217E+01 1.837E+00
 4.3178E+01 1.633E+00
 4.4235E+01 1.233E+00
 4.5196E+01 1.029E+00