DARPE: Search Results
 /*===================================================================*/
 /* NRDF D1769 Data No.25                                             */
 /*===================================================================*/
 /* Bibliography                                                      */
 /*===================================================================*/
 \\BIB,25;
 D#=D1769;
 TITLE=/ Double-differential cross sections for the neutron
         production from heavy-ion reactions at energies E/A = 290-600
         MeV /;
 PURPOSE=/ Systematic measurements of neutron-production cross
           sections from C, Ne, and Ar projectiles having E/A = 290-600
           MeV on C, Cu, and Pb targets. /;
 ATH=(Y.IWATA'1', T.MURAKAMI'1', H.SATO'2', H.IWASE'2', T.NAKAMURA'2',
      T.KUROSAWA'2', L.HEILBRONN'3', R.M.RONNINGEN'4', K.IEKI'5',
      Y.TOZAWA'5', K.NIITA'6');
 INST-ATH=(2JPNIRS'1', 2JPNTOH'2', 1USABRK'3', 1USAMSU'4', 2JPNRIK'5',
           2JPNJPN'6');
      /* '1' Department of Accelerator Physics and Engineering */
      /* '2' Cyclotron and Radioisotope Center */
      /* '4' National Superconducting Cyclotron Laboratory */
      /* '5' Department of Physics */
      /* '6' Research Organization for Information Science and
              Technology, Tokai, Naka, Ibaraki */
 REF=PR/C;
 VLP=64(2001)054609;
 RCTS=(C(12C,N)X, CU(12C,N)X, PB(12C,N)X, C(20NE,N)X, CU(20NE,N)X,
       PB(20NE,N)X, C(40AR,N)X, CU(40AR,N)X, PB(40AR,N)X);
 PHQS=(ENGY-SPEC, ANGL-DSTRN, XSECTN, TOT-XSECTN, MLT);
 /*===================================================================*/
 /* Experimental Conditions                                           */
 /*===================================================================*/
 \\EXP,25;
 /* 2002-08-01 : Compiled, Am + Sr + On */
 /* 2006-07-25 : Altered, On. Heading of data error corrected.
    Systematic uncertainties added. */
 RTY=HEAVY-ION-RCT;
 ENR=NAT;
 CHM=ELM;
 PHYS-FORM=SLD;
 BAC=X;
 POL-TGT=0%;
 ALGN-TGT=0%;
 ACC=SYN'7';
 /* '7' Heavy Ion Medical Accelerator in Chiba (HIMAC) facility
 INST-ACC=2JPNIRS;
 BEAM-INTNSTY=XMA'8';
 /* '8' A few times 10e4-10e5 particles per pulse */
 POL-PRJ=0%;
 DET-PARTCL=N;
 COINC=NO;
 ANT-COINC=NO;
 DET-SYS=(SCT'9',SCT'10',TOF);
 /* '9' NE102A plastic scintillator */
 /* '10' NE213 liquid scintillator */
 ERS-DET=XKEV'11';
 /* '11' The energy resolutions are shown in Table I in reference.
 /* Experimental Method:
    - Time-of-flight
 RCT=C(12C,N)X;
 PHQ=ENGY-SPEC;
 THK-TGT=9000MG/CM**2;
 INC-ENGY-LAB=400.0MEV/A;
 ANL=X'85';
 /* '85' Moving-source model, QMD and HIC */
 /*===================================================================*/
 /* Descriptive Parameters                                            */
 /*===================================================================*/
 \\DATA,25;
 SYS-ERR=10%'12';
 /* '12' Uncertainty in detection efficiency */
 INC-ENGY-LAB=400.0MEV/A;
 SYS-ERR=6.8%'86';
 /* '86' Uncertainty in target thickness */
 THTL=30DEG;
 /*===================================================================*/
 /* Data Table                                                        */
 /*===================================================================*/
 \DATA;
 ENGY-EMT-LAB DSIGMA/DOMEGA/DE DELTA-DSIGMA/DOMEGA/DE'87'
 (MEV) (MB/SR/MEV) (MB/SR/MEV)
 5 72.9 +-28.3
 6 11.6 +-3.9
 7 7.86 +-1.91
 8 6.55 +-1.37
 9 2.40 +-1.27
 10 4.15 +-1.09
 15 2.27 +-0.27
 25 2.07 +-0.22
 35 1.64 +-0.22
 45 1.64 +-0.21
 55 1.53 +-0.20
 65 1.90 +-0.21
 75 1.70 +-0.21
 85 1.70 +-0.22
 95 1.88 +-0.22
 105 1.90 +-0.20
 125 1.36 +-0.17
 145 1.41 +-0.15
 165 1.24 +-0.13
 185 1.24 +-0.13
 205 1.17 +-0.12
 235 1.01 +-0.09
 265 0.844 +-0.082
 295 0.735 +-0.066
 325 0.655 +-0.062
 365 0.426 +-0.046
 405 0.289 +-0.032
 465 0.182 +-0.020
 525 6.55e-02 +-1.25e-02
 605 3.82e-02 +-7.60e-03
 725 1.82e-03 +-5.62e-03
 885 4.09e-03 +-1.79e-03
 1085 3.28e-03 +-1.42e-03
 1285 1.09e-03 +-7.51e-04
 1685 1.09e-03 +-6.21e-04
 1885 0.00e+00 +-4.76e-04
 \END;
 /*===================================================================*/