DARPE: Search Results
 /*===================================================================*/
 /* NRDF D1434 Data No.27                                             */
 /*===================================================================*/
 /* Bibliography                                                      */
 /*===================================================================*/
 \\BIB,27;
 D#=D1434;
 TITLE=/Nuclear structure of even lead isotopes by the (p,t) reaction/;
 ATH=(M.TAKAHASHI'1', T.MURAKAMI'1', S.MORITA'1', H.ORIHARA'2',
      Y.ISHIZAKI'3', H.YAMAGUCHI'4');
 INST-ATH=(2JPNTOH'1', 2JPNTOH'2', 2JPNINS'3', 2JPNTKS'4');
      /* '1' Department of Physics */
      /* '2' Cyclotron and Radioisotope Center */
      /* '3' Institute for Nuclear Study */
      /* '4' Faculty of General Education */
 REF=PR/C;
 VLP=27(1983)1454;
 RCTS=(208PB(P,T)206PB, 206PB(P,T)204PB, 204PB(P,T)202PB);
 PHQS=ANGL-DSTRN;
 /*===================================================================*/
 /* Experimental Conditions                                           */
 /*===================================================================*/
 \\EXP,27;
 /* 2003-10-24 : Converted, Data converted to EXFOR E1434 and EXFOR
    O0685 */
 PHQ=ANGL-DSTRN;
 ENR=>99%;
 POL-TGT=0%;
 ALGN-TGT=0%;
 ACC=SYNCYC;
 INST-ACC=2JPNINS;
 INC-ENGY-LAB=51.9MEV;
 POL-PRJ=0%;
 DET-PARTCL=T;
 COINC=NO;
 ANT-COINC=NO;
 DET-SYS=(MAG'5',PROP-CNTR'6',SCT);
 /* '5' To analyze triton momentum */
 /* '6' Array of 200 proportional counters serve as position
        detectors. They form counter telescopes in combination with
        scintillation counters. */
 ERS-DET=[90KEV'7';
 /* '7' Overall energy resolution for the tritons of interest */
 ANL=DWBA'8';
 /* '8' Zero-range DWBA approximation (code DWUCK-4, [W.A.Lanford
        and J.B.McGrory, Michigan State University Cyclotron Laboratory
        Report No.MSUCL-81, 1973 (unpublished); Phys. Lett.
        45B(1973)283]) */
 RCT=204PB(P,T)202PB;
 CHM=ELM'128';
 /* '128' Prepared by centrifugal settling of PbO */
 PHYS-FORM=SLD;
 THK-TGT=2MG/CM**2;
 BAC=MYLAR;
 /*===================================================================*/
 /* Descriptive Parameters                                            */
 /*===================================================================*/
 \\DATA,27;
 INC-ENGY-LAB=51.9MEV;
 SYS-ERR=<20%'129';
 /* '129' Error of the absolute cross section of the ground state
          transition is estimated to be less than 20%, where the main
          part comes from the uncertainty of the solid angle of each
          counter on the focal plane of the magnetic spectrograph. */
 EMT=T;
 RSD=202PB;
 EXC-ENGY=1.77MEV;
 J-PTY=4+;
 DELTA-THTC=0.25DEG'130';
 /* '130' Data-point reader uncertainty */
 DELTA-DSIGMA/DOMEGA=1.9%'131';
 /* '131' Data-point reader uncertainty */
 /*===================================================================*/
 /* Data Table                                                        */
 /*===================================================================*/
 \DATA;
 THTC DSIGMA/DOMEGA DELTA-DSIGMA/DOMEGA'132'
 (DEG) (UB/SR) (%)
 6.27           14.78          +-X
 8.32           13.32          +-2.
 10.54          11.69          +-X
 13.31          7.8            +-8.
 18.12          4.             +-10.
 23.46          4.             +-10.
 25.85          4.7            +-11.
 27.9           3.1            +-13.
 30.67          2.6            +-12.
 33.46          1.14           +-22.
 35.65          1.59           +-17.
 38.23          1.97           +-6.
 40.45          1.71           +-8.
 46.18          0.98           +-18.
 50.79          0.84           +-14.
 56.15          0.5            +-22.
 \END;
 /*===================================================================*/