 /* NRDF D1586 Data No.27                                             */
 /*===================================================================*/
 /* Bibliography                                                      */
 /*===================================================================*/
 \\BIB,27;
 D#=D1586;
 TITLE=/ Single-particle states in 59Ni with 58Ni(d,p)59Ni reaction
         at 56 MeV and neutron-bound-state complex potentials /;
 PURPOSE=/ To measure the cross sections and analyzing powers /;
 ATH=(O.IWAMOTO'1', A.NOHTOMI'1', Y.UOZUMI'1', T.SAKAE'1', M.MATOBA'1',
      M.NAKANO'2', T.MAKI'2', N.KOORI'3');
 INST-ATH=(2JPNKYU'1', 2JPNKIT'2', 2JPNTKS'3');
      /* '1' Department of Nuclear Engineering */
      /* '2' School of Nursing and Technology */
      /* '3' Faculty of Integrated Arts and Sciences */
 REF=NP/A;
 VLP=576(1994)387;
 RCTS=58NI(D,P)59NI;
 PHQS=(SPEC-FCTR, ANGL-DSTRN, VCTR-ANALPW, SPEC-FCTR'4');
 /* '4' Sum of spectroscopic factor */
 /*===================================================================*/
 /* Experimental Conditions                                           */
 /*===================================================================*/
 \\EXP,27;
 /* 2005-09-24 : Converted, Sr + On. Converted to EXFOR E1586 */
 /* 2005-11-07 : Altered, At + Kc + Sr. Re-digitized */
 /* Related references 
    - N.Matsuoka et al., NP/A, 455(1986)413.
 ENR=99.89%;
 CHM=ELM;
 PHYS-FORM=SLD;
 THK-TGT=0.473MG/CM**2;
 POL-TGT=0%;
 ALGN-TGT=0%;
 ACC=CYC'5';
 /* '5' Isochronous cyclotron, AVF cyclotron */
 INST-ACC=2JPNRCN;
 INC-ENGY-LAB=56MEV;
 POL-PRJ=[50%;
 DET-PARTCL=P;
 COINC=NO;
 ANT-COINC=NO;
 DET-SYS=MAG'6';
 /* '6' Magnetic spectrograph RAIDEN [H.Ikegami, et al. Nucl.
        Instr. Meth. 175(1980)33] with the focal-plane detector system
        KYUSHYU [M.Matoba, et al. Nucl. Instr. Meth. 180(1981)419] */
 ERS-DET=45KEV;
 ANL=DWBA'7';
 /* '7' Code DWUCK [P.D.Kunz, code DWUCK, University of Colorado
        (unpublished)] */
 RCT=58NI(D,P)59NI;
 PHQ=VCTR-ANALPW;
 /*===================================================================*/
 /* Descriptive Parameters                                            */
 /*===================================================================*/
 \\DATA,27;
 INC-ENGY-LAB=56MEV;
 SYS-ERR=X%'124';
 /* '124' Uncertainty in run-to-run variations of the integrated
          beam current are on the order of a few percent. */
 EMT=P;
 EXC-ENGY=0.340MEV;
 J-PTY=5/2-;
 TRNSF-L=3'125';
 /* '125' Transferred angular momentum (L) */
 TRNSF-J=5/2'126';
 /* '126' Transferred spin (J) */
 /*===================================================================*/
 /* Data Table                                                        */
 /*===================================================================*/
 \DATA;
 THTC AY DELTA-AY'127'
 (DEG) (NODIM) (NODIM)
 5.367E+00 8.601E-02 +-4.070E-02
 8.495E+00 -1.944E-03 +-3.488E-02
 1.163E+01 -1.655E-01 +-2.907E-02
 1.477E+01 -3.174E-01 +-2.907E-02
 1.776E+01 -4.053E-01 +-2.907E-02
 2.074E+01 -4.467E-01 +-2.326E-02
 2.371E+01 -4.242E-01 +-2.907E-02
 2.668E+01 -4.016E-01 +-2.907E-02
 2.993E+01 -3.617E-01 +-2.907E-02
 3.405E+01 -4.324E-01 +-3.488E-02
 3.816E+01 -4.799E-01 +-4.070E-02
 4.212E+01 -4.344E-01 +-4.070E-02
 \END;
 /*===================================================================*/