DARPE: Search Results
 /*===================================================================*/
 /* NRDF D0815 Data No.3                                              */
 /*===================================================================*/
 /* Bibliography                                                      */
 /*===================================================================*/
 \\BIB,3;
 D#=D815;
 TITLE=/Analyzing power of the neutron continuum spectrum for the
        93Nb(p,nX) reaction at 65 MeV and a DWBA analysis/;
 PURPOSE=/To provide stringent test for various theories by simultaneous
          fitting of analyzing powers as well as cross sections for both
          neutron and proton spectra/;
 ATH=(H.SAKAI'1', K.HATANAKA'1', N.MATSUOKA'1', T.SAITO'1',
      A.SHIMIZU'1', T.MOTOBAYASHI'2', T.SHIBATA'1');
 INST-ATH=(2JPNRCN'1', 2JPNOSA'2');
      /* '2' Department of Physics */
 REF=PL/B;
 VLP=133(1983)375;
 RCTS=93NB(P,N)X;
 PHQS=(ENGY-SPEC'3', ANALPW, ANGL-DSTRN);
 /* '3' Double differential cross section */
 /*===================================================================*/
 /* Experimental Conditions                                           */
 /*===================================================================*/
 \\EXP,3;
 /* 2003-10-24 : Converted, Data converted to EXFOR E815 and EXFOR
    O0522 */
 ENR=X%;
 CHM=ELM;
 PHYS-FORM=SLD'4';
 /* '4' Metallic foil */
 THK-TGT=43.6MG/CM**2;
 BAC=SELF;
 POL-TGT=0%;
 ALGN-TGT=0%;
 ACC=CYC'5';
 /* '5'Isochronous cyclotron, RCNP AVF cyclotron */
 INST-ACC=2JPNRCN;
 INC-ENGY-LAB=65MEV;
 BEAM-INTNSTY=50NA'6';
 /* '6' maximum beam current */
 POL-PRJ=82.5+-2.5%'7';
 /* '7' The beam polarization was measured continuously with a
        12C-polarimeter placed down stream the main scattering chamber
 DET-PARTCL=N;
 COINC=NO;
 ANT-COINC=NO;
 DET-SYS=SCT'8';
 /* '8' two liquid scintillation counters (NE213) to detect
        neutrons */
 /* Experimental Method:
    - Time-of-flight (To determine outgoing neutron energy. The time
      resolution (FWHM) of the beam burst was typically 1.0-1.5 ns, and
      corresponding energy resolutions of the neutrons were about 4 and
      2 MeV for 50 and 30 MeV neutrons, respectively.)
 RCT=93NB(P,N)X;
 PHQ=ENGY-SPEC'17';
 /* '17' Double differential cross section */
 /*===================================================================*/
 /* Descriptive Parameters                                            */
 /*===================================================================*/
 \\DATA,3;
 INC-ENGY-LAB=65MEV;
 SYS-ERR=10%'18';
 /* '18' Estimated errors in the absolute magnitude of the cross
         section due to uncertainties in the neutron detection
         efficiency calculation */
 EMT=N;
 THTL=70DEG;
 DELTA-ENGY-EMT-LAB=0.27MEV'19';
 /* '19' Data-point reader uncertainty */
 DELTA-DSIGMA/DOMEGA/DE=+-3.0%'20';
 /* '20' Data-point reader uncertainty */
 /*===================================================================*/
 /* Data Table                                                        */
 /*===================================================================*/
 \DATA;
 ENGY-EMT-LAB DSIGMA/DOMEGA/DE
 (MEV) (MB/SR/MEV)
 16.43       1.07
 17.24      0.944
 19.19      0.891
 20.39      0.788
 21.39      0.711
 22.57       0.67
 23.56      0.605
 24.93      0.583
 26.49      0.561
 27.66      0.551
 29.23       0.52
 30.22      0.479
 31.98      0.462
 34.14       0.41
 35.33      0.378
  36.9      0.357
 38.27      0.336
 40.44      0.292
 42.03      0.248
 43.03      0.224
 44.21      0.215
   45.      0.198
 46.01      0.172
 47.38      0.165
 47.99      0.149
 48.79      0.135
 49.98      0.124
 50.79      0.107
 52.18      0.095
 52.99     0.0822
 53.79     0.0757
  54.8     0.0642
 56.24      0.047
 56.91     0.0344
 58.16     0.0241
 59.04     0.0162
 59.59    0.00882
 60.93    0.00451
 \END;
 /*===================================================================*/