DARPE: Search Results
 /*===================================================================*/
 /* NRDF D0816 Data No.3                                              */
 /*===================================================================*/
 /* Bibliography                                                      */
 /*===================================================================*/
 \\BIB,3;
 D#=D816;
 TITLE=/ Tensor analyzing powers of the proton continuum spectra from
         deuteron breakup at 56 MeV /;
 ATH=(N.MATSUOKA'1', K.HATANAKA'1', H.SAKAI'1', T.SAITO'1', K.HOSONO'1',
      T.ITAHASHI'1', A.SHIMIZU'1', M.KONDO'1', H.SAKAGUCHI'2',
      F.OHTANI'2');
 INST-ATH=(2JPNRCN'1', 2JPNKTO'2');
      /* '2' Department of Physics */
 REF=NP/A;
 VLP=408(1983)99;
 RCTS=(58NI(D,P)X, 90ZR(D,P)X);
 PHQS=(DBL-DIFF-XSECTN, TNSR-ANALPW);
 /*===================================================================*/
 /* Experimental Conditions                                           */
 /*===================================================================*/
 \\EXP,3;
 /* 2007-08-24 : Converted, N.Otuka. Converted to EXFOR E0816 */
 CHM=ELM;
 PHYS-FORM=SLD;
 POL-TGT=0%;
 ALGN-TGT=0%;
 ACC=CYC'3';
 /* '3' Isochronous cyclotron, AVF cyclotron */
 INST-ACC=2JPNRCN;
 INC-ENGY-LAB-RANGE=56MEV;
 BEAM-INTNSTY=5[40NA;
 POL-PRJ=70[80%;
 DET-PARTCL=P;
 COINC=NO;
 ANT-COINC=NO;
 DET-SYS=(SI'4',GE'4',SI'5',NAI'5',EDE);
 /* '4' To detect protons */
 /* '5' To detect protons (6, 8, 10, 13 deg) */
 RCT=58NI(D,P)X;
 PHQ=DBL-DIFF-XSECTN;
 ENR=99.8%;
 THK-TGT=3.79MG/CM**2;
 /* Data points lower than 20 MeV and higher than 45 MeV are mostly
    omitted because of high density of data points */
 /*===================================================================*/
 /* Descriptive Parameters                                            */
 /*===================================================================*/
 \\DATA,3;
 INC-ENGY-LAB=56MEV;
 STATIST-ERR=<2.5%'10';
 /* '10' Maximum statistical uncertainty (<2.5%) */
 THTL=10DEG;
 DELTA-DSIGMA/DOMEGA/DE=10%'11';
 /* '11' Uncertainty in absolute cross section, mainly due to
         uncertainty in target thickness */
 /*===================================================================*/
 /* Data Table                                                        */
 /*===================================================================*/
 \DATA;
 ENGY-EMT-LAB DSIGMA/DOMEGA/DE
 (MEV) (MB/SR/MEV)
 1.8589E+01 2.112E+01
 1.9468E+01 2.423E+01
 2.0542E+01 2.850E+01
 2.1621E+01 3.510E+01
 2.2505E+01 4.054E+01
 2.3581E+01 4.597E+01
 2.4562E+01 5.160E+01
 2.5447E+01 5.801E+01
 2.6425E+01 6.267E+01
 2.7498E+01 6.616E+01
 2.8471E+01 6.791E+01
 2.9440E+01 6.809E+01
 3.0408E+01 6.770E+01
 3.1472E+01 6.672E+01
 3.2437E+01 6.476E+01
 3.3489E+01 5.775E+01
 3.4547E+01 5.386E+01
 3.5409E+01 4.879E+01
 3.6466E+01 4.431E+01
 3.7521E+01 3.925E+01
 3.8575E+01 3.302E+01
 3.9439E+01 2.912E+01
 4.0399E+01 2.484E+01
 4.1362E+01 2.191E+01
 4.2230E+01 1.957E+01
 4.3289E+01 1.626E+01
 4.4352E+01 1.469E+01
 4.5413E+01 1.216E+01
 \END;
 /*===================================================================*/