/*===================================================================*/ /* NRDF D1242 Data No.3 */ /*===================================================================*/ /* Bibliography */ /*===================================================================*/ \\BIB,3; D#=D1242; TITLE=/ Nuclear reactions of 48Ti, 56Fe, 57Fe, 58Ni, 60Ni, 63Cu, and 65Cu by 12-GeV protons /; ATH=(M.NOGUCHI'1', H.HIRABAYASHI'1', K.KATOH'1', K.KONDO'1', M.TAKASAKI'1', Y.ASANO'2', S.MORI'2', M.SAKANO'2'); INST-ATH=(2JPNKEK'1', 2JPNTSU'2'); /* '2' Institute of Applied Physics */ REF=PR/C; VLP=38(1988)1811; RCTS=(48TI(P,X)X, 56FE(P,X)X, 57FE(P,X)X, 58NI(P,X)X, 60NI(P,X)X, 63CU(P,X)X, 65CU(P,X)X); PHQS=XSECTN; /*===================================================================*/ /* Experimental Conditions */ /*===================================================================*/ \\EXP,3; /* 2007-01-18 : Converted, N.Otuka. Converted to EXFOR E1242 */ PHQ=XSECTN; /* Additional results shown but not compiled - Charge distribution (Shown in Fig.6 in reference) PHYS-FORM=SLD; POL-TGT=0%; ALGN-TGT=0%; ACC=SYN; INST-ACC=2JPNKEK; INC-ENGY-LAB-RANGE=12GEV; POL-PRJ=0%; DET-PARTCL=GAMMA'3'; /* '3' Decay data not given */ COINC=NO; ANT-COINC=NO; DET-SYS=GE(LI)'4'; /* '4' For gamma-ray spectroscopy */ /* Experimental Method: - Stacked target irradiation - Activation (Irradiated for 14 min) - Gamma ray spectrometry (Performed during 3 months starting about 4 hours after the end of irradiation. In addition 56Fe and 57Fe targets were measured about 15 months after irradiation.) /* By authors: Measurements of short-lived nuclides with lifetimes much shorter than a few hours were precluded. */ RCT=56FE(P,X)X'12'; /* '12' See DATA section for atomic number (Z) and mass number (A) of products */ ENR=99.93%; CHM=FE2.O3; THK-TGT=10MG/CM**2; /*===================================================================*/ /* Descriptive Parameters */ /*===================================================================*/ \\DATA,3; INC-ENGY-LAB=12GEV; TOT-ERR=X%'5'; /* '5' Uncertainty in detection efficiency of gamma rays and statistical errors for photopeak yields (Uncertainties in normalization are not included.) */ SYS-ERR=(10%'6',15%'7'); /* '6' Uncertainty in beam intensity calibration */ /* '7' Maximum uncertainty in detection efficiency (15% below 200 keV, 10% at 200-400 keV, 5% above 400 keV) */ /*===================================================================*/ /* Data Table */ /*===================================================================*/ \DATA; Z A ISOMER SIGMA',13' DELTA-SIGMA'' (NODIM) (NODIM) (NODIM) (MB) (MB) 19. 42 X 2.9 +-0.2 21. 44 0 3.0 +-0.15 21. 44 1 3.1 +-0.16 21. 46 X 4.5 +-0.2 21. 48 X 0.22 +-0.04 24. 48 X 0.20 +-0.01 25. 52 X 3.3 +-0.17 25. 54 X 23 +-1.2 \END; /*===================================================================*/ |