/*===================================================================*/ /* NRDF D1849 Data No.3 */ /*===================================================================*/ /* Bibliography */ /*===================================================================*/ \\BIB,3; D#=D1849; TITLE=/Some evidence for neutron pick-up from the interior core through the (p,d) reaction/; ATH=(T.ISHIMATSU'1', S.HAYASHIBE'1', N.KAWAMURA'1', T.AWAYA'2', H.OHMURA'2', Y.NAKAJIMA'3', S.MITARAI'3'); INST-ATH=(2JPNTOH'1', 2JPNTOK'2', 2JPNKYU'3'); /* '1' Department of Physics */ /* '2' Department of Physics */ /* '3' Department of Physics */ REF=NP/A; VLP=185(1972)273; RCTS=(100MO(P,D)99MO, 94MO(P,D)93MO, 98MO(P,D)97MO); PHQS=ANGL-DSTRN; /*===================================================================*/ /* Experimental Conditions */ /*===================================================================*/ \\EXP,3; /* 2003-10-31 : Converted, Data converted from EXFOR O0586 */ PHQ=ANGL-DSTRN; CHM=ELM; PHYS-FORM=SLD'4'; /* '4' Metallic foils */ POL-TGT=0%; ALGN-TGT=0%; ACC=SYNCYC; INST-ACC=2JPNINS; INC-ENGY-LAB=52MEV; POL-PRJ=0%; DET-PARTCL=D; COINC=NO; ANT-COINC=NO; DET-SYS=(MAG'5',PROP-CNTR'6',PLST-SCT); /* '5' Broad-range magnetic spectrometer [K.Yagi et al., Nucl. Instr. 52(1967)29] */ /* '6' 200 proportional counters along the focal plane followed by a plastic scintillation counter with 6 phototubes */ /* Experimental Method: - Pulse-height discrimination (Aluminium foils placed in tront of proportional counters and a pulse-height discriminator for the outputs from the scintillation counters allowed the elimination of triton backgrounds from deuteron spectra.) RCT=100MO(P,D)99MO; ENR=95.9%; THK-TGT=3.0MG/CM**2; /*===================================================================*/ /* Descriptive Parameters */ /*===================================================================*/ \\DATA,3; INC-ENGY-LAB=52MEV; SYS-ERR=(10%'17',X%'18'); /* '17' Uncertainty in the solid angle of spectrometer */ /* '18' Uncertainties in the absolute cross sections are estimated to be less than +-20%. */ EMT=D; RSD=99MO; EXC-ENGY=0.10MEV; DELTA-EXC-ENGY=0.02MEV; J-PTY=5/2+; DELTA-THTL=0.23DEG'19'; /* '19' Data-point reader uncertainty */ DELTA-DSIGMA/DOMEGA=1.6%'20'; /* '20' Data-point reader uncertainty */ /*===================================================================*/ /* Data Table */ /*===================================================================*/ \DATA; THTL DSIGMA/DOMEGA (DEG) (MB/SR) 4.91 12.5 7.98 10.89 11.19 8.2 14. 4.5 16.83 2.73 20.25 2.62 23.04 2.7 25.79 2.42 29.87 1.118 33.96 0.536 37.85 0.472 42.08 0.437 46.08 0.298 49.71 0.1636 54.04 0.1158 \END; /*===================================================================*/ |