DARPE: Search Results
 /*===================================================================*/
 /* NRDF D1941 Data No.3                                              */
 /*===================================================================*/
 /* Bibliography                                                      */
 /*===================================================================*/
 \\BIB,3;
 D#=D1941;
 TITLE=/ The elastic and inelastic scattering of protons by magnesium
         in the energy range from 7.3 MeV to 15.9 MeV /;
 ATH=(K.MATSUDA'1', Y.NAGAHARA'1', Y.ODA'1', N.YAMAMURO'1',
      S.KOBAYASHI'1');
 INST-ATH=(2JPNINS'1');
 REF=NP;
 VLP=27(1961)1;
 /* Secondary reference 
    - INS-J, 29(1960) (N.Yamamuro et al., Numerical data)
 RCTS=(24MG(P,P)24MG, MG(P,P)MG);
 PHQS=(ANGL-DSTRN, XSECTN, EXC-FUNCT);
 /*===================================================================*/
 /* Experimental Conditions                                           */
 /*===================================================================*/
 \\EXP,3;
 /* 2005-10-20 : Compiled, Kc + On. */
 ENR=NAT;
 POL-TGT=0%;
 ALGN-TGT=0%;
 ACC=CYC;
 INST-ACC=2JPNINS;
 DELTA-INC-ENGY-LAB=100KEV'2';
 /* '2' Absolute errors in beam energy determination */
 ERS-PRJ=50KEV'3';
 /* '3' Relative errors in beam energy determination */
 POL-PRJ=0%;
 DET-PARTCL=P;
 COINC=NO;
 ANT-COINC=NO;
 DET-SYS=(SCT'4',PROP-CNTR'5');
 /* '4' To measure angluar distributions and emitted spectra */
 /* '5' To measure emitted spectrum, and to suppress gamma and
        alpha in angular distribution measurements */
 RCT=MG(P,P)MG;
 RTY=ELA-SCATT;
 PHQ=ANGL-DSTRN;
 INC-ENGY-LAB=7.32MEV;
 /*===================================================================*/
 /* Descriptive Parameters                                            */
 /*===================================================================*/
 \\DATA,3;
 DELTA-INC-ENGY-LAB=100KEV'6';
 /* '6' Absolute errors in beam energy determination */
 SYS-ERR=10%'7';
 /* '7' Uncertainty in absolute cross section */
 STATIST-ERR=<3%'8';
 /* '8' Maximum uncertainty in counting statistics in most cases.
        This is modified to +5%-8% at 90 deg to 165 deg due to
        insufficient discrimination in inelastic scattering */
 INC-ENGY-LAB=7.32MEV;
 /*===================================================================*/
 /* Data Table                                                        */
 /*===================================================================*/
 \DATA;
 THTC DSIGMA/DOMEGA
 (DEG) (MB/SR)
 20.6 1980
 31.2 474
 41.5 190
 51.8 81.6
 62.1 40.1
 72.2 34.7
 82.3 38.0
 92.4 41.3
 97.4 43.9
 107.3 37.1
 117.2 26.0
 127.0 16.4
 136.7 10.6
 146.4 15.2
 156.0 25.6
 165.6 43.3
 \END;
 /*===================================================================*/