/*===================================================================*/ /* NRDF D1996 Data No.3 */ /*===================================================================*/ /* Bibliography */ /*===================================================================*/ \\BIB,3; D#=D1996; TITLE=/ Alpha beam monitoring via natCu + alpha processes in the energy range from 40 to 60 MeV /; ATH=(F.SZELECSENYI'1', K.SUZUKI'2', Z.KOVACS'1', M.TAKEI'2', K.OKADA'2'); INST-ATH=(3HUNDEB'1', 2JPNIRS'2'); /* '1' Cyclotron Department */ /* '2' Division of Advanced Technology for Medical Imaging */ REF=NIM/B; VLP=184(2001)589; RCTS=(CU(ALPHA,X)61CU, CU(ALPHA,X)66GA, CU(ALPHA,X)67GA); PHQS=XSECTN; /*===================================================================*/ /* Experimental Conditions */ /*===================================================================*/ \\EXP,3; /* 2006-09-06 : Compiled, Tk + On */ PHQ=XSECTN; CHM=ELM; PHYS-FORM=SLD; POL-TGT=0%; ALGN-TGT=0%; ACC=CYC'3'; /* '3' Isochronous cyclotron, AVF cyclotron */ INST-ACC=2JPNIRS; BEAM-INTNSTY=(94NA,96NA,183NA); POL-PRJ=0%; COINC=NO; ANT-COINC=NO; DET-SYS=HPGE'4'; /* '4' To determine activity of samples */ /* Experimental Method: - Activation (Irradiated for 10, 20 and 30 min (3 runs)) - Stacked target irradiation (Stacks made up of natCu and natCo) - Beam current integrated (Via electric charge collection in Faraday cage) /* Related references - common, A0465006, J(Pram)31. . See also EXFOR commo.n. - Compared with present result, A0510375, B(Levk). . See also EXFOR 109.. - Compared with present result, A0353003, J(Radi)39. - Compared with present result, D4085003, J(Nucl)168. . See also EXFOR 61.. RCT=CU(ALPHA,X)67GA; INC-ENGY-LAB=15[59MEV; DET-PARTCL=GAMMA'18'; /* '18' Delayed gamma from 67Ga */ /*===================================================================*/ /* Descriptive Parameters */ /*===================================================================*/ \\DATA,3; TOT-ERR=12%; SYS-ERR=(8%'5',5%'6',3%'7'); /* '5' Uncertainty in flux measurement */ /* '6' Uncertainty in detector efficiency */ /* '7' Uncertainty in nuclear data */ STATIST-ERR=<1%'8'; /* '8' Maximum uncertainty in counting statistics */ ENGY-GAMMA=(93.31KEV'19',184.57KEV'20',300.21KEV'21'); INTNSTY-GAMMA=(0.370'19',0.204'20',0.166'21'); HALF-LIFE=(3.261DAY'21',3.261DAY'20',3.261DAY'19'); /* '19' Delayed gamma from 67Ga via NONe */ /* '20' Delayed gamma from 67Ga via NONe */ /* '21' Delayed gamma from 67Ga via NONe */ /*===================================================================*/ /* Data Table */ /*===================================================================*/ \DATA; INC-ENGY-LAB DELTA-INC-ENGY-LAB'22' SIGMA DELTA-SIGMA (MEV) (MEV) (MB) (MB) 15.9 +-1.9 8.12 +-0.89 19.2 +-1.7 97.8 +-10.8 20.8 +-2.6 237.2 +-26.1 22.3 +-1.6 238.7 +-26.3 25.1 +-1.5 338.4 +-37.2 25.7 +-2.3 344.6 +-37.9 27.7 +-1.3 351.2 +-38.6 28.9 +-2.2 348.9 +-38.0 30.0 +-1.2 340.7 +-37.0 32.1 +-2.0 275.8 +-30.3 32.3 +-1.1 296.8 +-32.3 34.2 +-1.9 197.2 +-21.6 34.4 +-1.0 240.6 +-26.2 35.3 +-1.8 185.0 +-20.1 36.5 +-0.9 190.3 +-21.0 37.9 +-1.7 119.1 +-13.1 38.3 +-1.7 126.9 +-14.0 40.3 +-0.7 99.5 +-11.0 41.1 +-1.5 76.8 +-8.5 41.2 +-1.5 57.8 +-6.4 43.7 +-1.4 54.3 +-6.0 44.5 +-1.4 40.8 +-4.1 46.8 +-1.3 40.9 +-4.5 47.6 +-1.2 38.6 +-4.3 49.9 +-1.1 32.3 +-3.5 50.6 +-1.1 34.4 +-3.8 52.7 +-1.0 30.9 +-3.4 53.3 +-0.9 23.0 +-2.6 55.4 +-0.8 26.3 +-2.9 56.0 +-0.8 20.7 +-2.3 58.1 +-0.7 26.7 +-2.9 \END; /*===================================================================*/ |