DARPE: Search Results
 /*===================================================================*/
 /* NRDF D1769 Data No.32                                             */
 /*===================================================================*/
 /* Bibliography                                                      */
 /*===================================================================*/
 \\BIB,32;
 D#=D1769;
 TITLE=/ Double-differential cross sections for the neutron
         production from heavy-ion reactions at energies E/A = 290-600
         MeV /;
 PURPOSE=/ Systematic measurements of neutron-production cross
           sections from C, Ne, and Ar projectiles having E/A = 290-600
           MeV on C, Cu, and Pb targets. /;
 ATH=(Y.IWATA'1', T.MURAKAMI'1', H.SATO'2', H.IWASE'2', T.NAKAMURA'2',
      T.KUROSAWA'2', L.HEILBRONN'3', R.M.RONNINGEN'4', K.IEKI'5',
      Y.TOZAWA'5', K.NIITA'6');
 INST-ATH=(2JPNIRS'1', 2JPNTOH'2', 1USABRK'3', 1USAMSU'4', 2JPNRIK'5',
           2JPNJPN'6');
      /* '1' Department of Accelerator Physics and Engineering */
      /* '2' Cyclotron and Radioisotope Center */
      /* '4' National Superconducting Cyclotron Laboratory */
      /* '5' Department of Physics */
      /* '6' Research Organization for Information Science and
              Technology, Tokai, Naka, Ibaraki */
 REF=PR/C;
 VLP=64(2001)054609;
 RCTS=(C(12C,N)X, CU(12C,N)X, PB(12C,N)X, C(20NE,N)X, CU(20NE,N)X,
       PB(20NE,N)X, C(40AR,N)X, CU(40AR,N)X, PB(40AR,N)X);
 PHQS=(ENGY-SPEC, ANGL-DSTRN, XSECTN, TOT-XSECTN, MLT);
 /*===================================================================*/
 /* Experimental Conditions                                           */
 /*===================================================================*/
 \\EXP,32;
 /* 2002-08-01 : Compiled, Am + Sr + On */
 /* 2006-07-25 : Altered, On. Heading of data error corrected.
    Systematic uncertainties added. */
 RTY=HEAVY-ION-RCT;
 ENR=NAT;
 CHM=ELM;
 PHYS-FORM=SLD;
 BAC=X;
 POL-TGT=0%;
 ALGN-TGT=0%;
 ACC=SYN'7';
 /* '7' Heavy Ion Medical Accelerator in Chiba (HIMAC) facility
 INST-ACC=2JPNIRS;
 BEAM-INTNSTY=XMA'8';
 /* '8' A few times 10e4-10e5 particles per pulse */
 POL-PRJ=0%;
 DET-PARTCL=N;
 COINC=NO;
 ANT-COINC=NO;
 DET-SYS=(SCT'9',SCT'10',TOF);
 /* '9' NE102A plastic scintillator */
 /* '10' NE213 liquid scintillator */
 ERS-DET=XKEV'11';
 /* '11' The energy resolutions are shown in Table I in reference.
 /* Experimental Method:
    - Time-of-flight
 RCT=CU(12C,N)X;
 PHQ=ENGY-SPEC;
 THK-TGT=13400MG/CM**2;
 INC-ENGY-LAB=400.0MEV/A;
 ANL=X'106';
 /* '106' Moving-source model, QMD and HIC */
 /*===================================================================*/
 /* Descriptive Parameters                                            */
 /*===================================================================*/
 \\DATA,32;
 SYS-ERR=10%'12';
 /* '12' Uncertainty in detection efficiency */
 INC-ENGY-LAB=400.0MEV/A;
 SYS-ERR=2.5%'107';
 /* '107' Uncertainty in target thickness */
 THTL=30DEG;
 /*===================================================================*/
 /* Data Table                                                        */
 /*===================================================================*/
 \DATA;
 ENGY-EMT-LAB DSIGMA/DOMEGA/DE DELTA-DSIGMA/DOMEGA/DE'108'
 (MEV) (MB/SR/MEV) (MB/SR/MEV)
 5 1046 +-116
 6 142 +-16
 7 68.5 +-7.7
 8 35.4 +-5.8
 9 31.5 +-4.9
 10 28.5 +-4.1
 15 13.0 +-1.1
 25 11.3 +-0.8
 35 10.8 +-0.8
 45 8.31 +-0.73
 55 8.16 +-0.72
 65 8.77 +-0.70
 75 6.62 +-0.70
 85 7.00 +-0.73
 95 7.16 +-0.69
 105 5.31 +-0.74
 125 6.69 +-0.54
 145 4.85 +-0.46
 165 3.69 +-0.45
 185 3.81 +-0.41
 205 4.15 +-0.37
 235 3.90 +-0.29
 265 2.51 +-0.22
 295 2.03 +-0.21
 325 1.69 +-0.17
 365 1.58 +-0.14
 405 0.712 +-0.098
 465 0.410 +-0.075
 525 0.308 +-0.045
 605 0.135 +-0.031
 725 5.13e-02 +-1.29e-02
 885 0.00e+00 +-7.83e-03
 1085 0.00e+00 +-6.99e-03
 1285 0.00e+00 +-5.47e-03
 1485 0.00e+00 +-1.94e-03
 1685 3.85e-03 +-2.29e-03
 1885 0.00e+00 +-1.71e-03
 \END;
 /*===================================================================*/