/*===================================================================*/ /* NRDF D1194 Data No.34 */ /*===================================================================*/ /* Bibliography */ /*===================================================================*/ \\BIB,34; D#=D1194; TITLE=/ Optical model and folding model potentials for elastic scattering of 56 MeV polarized deuterons /; ATH=(N.MATSUOKA'1', H.SAKAI'1', T.SAITO'1', K.HOSONO'1', M.KONDO'1', H.ITO'1', K.HATANAKA'2', T.ICHIHARA'2', A.OKIHANA'3', K.IMAI'4', K.NISIMURA'5'); INST-ATH=(2JPNRCN'1', 2JPNIPC'2', 2JPNKUE'3', 2JPNKTO'4', 2JPNINS'5'); /* '3' Department of Physics */ /* '4' Department of Physics */ REF=NP/A; VLP=455(1986)413; RCTS=(12C(D,D)12C, 16O(D,D)16O, 40CA(D,D)40CA, 58NI(D,D)58NI, 90ZR(D,D)90ZR, 118SN(D,D)118SN, 144SM(D,D)144SM, 208PB(D,D)208PB); PHQS=(ANGL-DSTRN, VCTR-ANALPW, TNSR-ANALPW, OPT-POTL-PARA); /*===================================================================*/ /* Experimental Conditions */ /*===================================================================*/ \\EXP,34; /* 2007-01-31 : Converted, N.Otuka. Converted to EXFOR E1194 */ RTY=ELA-SCATT; ENR=X%'6'; /* '6' Natural for 12C and 40Ca and enriched (96.7-99.8%) for 58Ni, 90Zr, 118Sn, 144Sm and 208Pb */ CHM=ELM; THK-TGT=1.88[16.4MG/CM**2'7'; /* '7' 1140 Torr for 16O */ BAC=SELF; ACC=CYC'8'; /* '8' Isochronous cyclotron, AVF cyclotron */ INST-ACC=2JPNRCN; INC-ENGY-LAB-RANGE=56MEV; BEAM-INTNSTY=10[200NA; POL-PRJ=80[85%; ION-SOURCE=/ Atomic beam source /; DET-PARTCL=D; COINC=NO; ANT-COINC=NO; DET-SYS=(CNTR-TLSCP'9',SI'9',NAI'9',EDE'10'); /* '9' To detect scattered particle */ /* '10' E and DE signal by Si and NaI detector */ ERS-DET=600KEV; ANL=OPT-MODEL; /* 2007-02-20 : Altered, At. Re-digitized */ RCT=16O(D,D)16O; PHQ=TNSR-ANALPW; PHYS-FORM=GAS; /*===================================================================*/ /* Descriptive Parameters */ /*===================================================================*/ \\DATA,34; INC-ENGY-LAB=56MEV; SYS-ERR=2.7%'67'; /* '67' Uncertainty in normalization of carbon polarimeter caused by absolute scale error */ /*===================================================================*/ /* Data Table */ /*===================================================================*/ \DATA; THTC AXZ DELTA-AXZ'68' (DEG) (NODIM) (NODIM) 1.657E+01 -1.012E-03 +-NEGLIGIBLE 1.920E+01 -8.388E-02 +-1.331E-02 2.239E+01 -1.054E-01 +-1.333E-02 2.563E+01 -5.220E-02 +-1.334E-02 2.831E+01 -2.566E-02 +-1.865E-02 3.367E+01 -9.935E-03 +-1.866E-02 3.901E+01 -1.289E-02 +-1.600E-02 4.486E+01 -6.391E-02 +-1.865E-02 5.024E+01 -1.512E-04 +-2.403E-02 5.560E+01 1.290E-02 +-2.139E-02 6.123E+01 6.063E-02 +-3.202E-02 6.682E+01 4.296E-03 +-2.135E-02 7.269E+01 -1.203E-02 +-2.136E-02 7.804E+01 3.694E-03 +-1.868E-02 8.283E+01 -3.125E-02 +-2.668E-02 8.791E+01 -3.153E-02 +-2.400E-02 9.717E+01 -2.108E-01 +-2.935E-02 1.071E+02 -1.713E-01 +-4.269E-02 1.170E+02 -6.511E-02 +-6.938E-02 \END; /*===================================================================*/ |