/*===================================================================*/ /* NRDF D1769 Data No.34 */ /*===================================================================*/ /* Bibliography */ /*===================================================================*/ \\BIB,34; D#=D1769; TITLE=/ Double-differential cross sections for the neutron production from heavy-ion reactions at energies E/A = 290-600 MeV /; PURPOSE=/ Systematic measurements of neutron-production cross sections from C, Ne, and Ar projectiles having E/A = 290-600 MeV on C, Cu, and Pb targets. /; ATH=(Y.IWATA'1', T.MURAKAMI'1', H.SATO'2', H.IWASE'2', T.NAKAMURA'2', T.KUROSAWA'2', L.HEILBRONN'3', R.M.RONNINGEN'4', K.IEKI'5', Y.TOZAWA'5', K.NIITA'6'); INST-ATH=(2JPNIRS'1', 2JPNTOH'2', 1USABRK'3', 1USAMSU'4', 2JPNRIK'5', 2JPNJPN'6'); /* '1' Department of Accelerator Physics and Engineering */ /* '2' Cyclotron and Radioisotope Center */ /* '4' National Superconducting Cyclotron Laboratory */ /* '5' Department of Physics */ /* '6' Research Organization for Information Science and Technology, Tokai, Naka, Ibaraki */ REF=PR/C; VLP=64(2001)054609; RCTS=(C(12C,N)X, CU(12C,N)X, PB(12C,N)X, C(20NE,N)X, CU(20NE,N)X, PB(20NE,N)X, C(40AR,N)X, CU(40AR,N)X, PB(40AR,N)X); PHQS=(ENGY-SPEC, ANGL-DSTRN, XSECTN, TOT-XSECTN, MLT); /*===================================================================*/ /* Experimental Conditions */ /*===================================================================*/ \\EXP,34; /* 2002-08-01 : Compiled, Am + Sr + On */ /* 2006-07-25 : Altered, On. Heading of data error corrected. Systematic uncertainties added. */ RTY=HEAVY-ION-RCT; ENR=NAT; CHM=ELM; PHYS-FORM=SLD; BAC=X; POL-TGT=0%; ALGN-TGT=0%; ACC=SYN'7'; /* '7' Heavy Ion Medical Accelerator in Chiba (HIMAC) facility INST-ACC=2JPNIRS; BEAM-INTNSTY=XMA'8'; /* '8' A few times 10e4-10e5 particles per pulse */ POL-PRJ=0%; DET-PARTCL=N; COINC=NO; ANT-COINC=NO; DET-SYS=(SCT'9',SCT'10',TOF); /* '9' NE102A plastic scintillator */ /* '10' NE213 liquid scintillator */ ERS-DET=XKEV'11'; /* '11' The energy resolutions are shown in Table I in reference. /* Experimental Method: - Time-of-flight RCT=CU(12C,N)X; PHQ=ENGY-SPEC; THK-TGT=13400MG/CM**2; INC-ENGY-LAB=400.0MEV/A; ANL=X'112'; /* '112' Moving-source model, QMD and HIC */ /*===================================================================*/ /* Descriptive Parameters */ /*===================================================================*/ \\DATA,34; SYS-ERR=10%'12'; /* '12' Uncertainty in detection efficiency */ INC-ENGY-LAB=400.0MEV/A; SYS-ERR=2.5%'113'; /* '113' Uncertainty in target thickness */ THTL=60DEG; /*===================================================================*/ /* Data Table */ /*===================================================================*/ \DATA; ENGY-EMT-LAB DSIGMA/DOMEGA/DE DELTA-DSIGMA/DOMEGA/DE'114' (MEV) (MB/SR/MEV) (MB/SR/MEV) 5 75.5 +-3.3 6 46.4 +-2.5 7 40.8 +-2.1 8 26.7 +-2.0 9 21.6 +-1.8 10 22.0 +-1.6 15 10.6 +-0.4 25 7.98 +-0.37 35 6.52 +-0.37 45 4.97 +-0.33 55 4.69 +-0.34 65 4.64 +-0.35 75 4.18 +-0.28 85 3.99 +-0.29 95 3.71 +-0.31 105 3.19 +-0.27 125 2.77 +-0.19 145 2.06 +-0.15 165 1.45 +-0.13 185 1.10 +-0.10 205 0.938 +-0.095 235 0.672 +-0.070 265 0.297 +-0.046 295 0.250 +-0.044 325 0.156 +-0.031 365 8.21e-02 +-2.50e-02 405 2.35e-02 +-1.91e-02 465 2.35e-02 +-9.50e-03 525 0.00e+00 +-1.08e-02 605 1.76e-02 +-6.45e-03 725 0.00e+00 +-5.31e-03 885 2.93e-03 +-2.62e-03 1085 7.04e-03 +-2.93e-03 1285 7.04e-03 +-4.00e-03 1485 4.69e-03 +-3.77e-03 1685 2.35e-03 +-1.83e-03 1885 0.00e+00 +-9.15e-04 \END; /*===================================================================*/ |